Records from 2016 to 2025. Most recent: inspection, 14 July 2025.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 17
14 July 2025
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8185618
20 May 2025
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8121263
11 February 2025
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8069577
6 May 2024
COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7907275
31 May 2023
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7702126
24 January 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7626797
9 June 2022
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7472569
9 August 2021
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7256349
21 January 2021
Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7128336
27 July 2020
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7017334
29 May 2020
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6961552
13 May 2019
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6673532
6 February 2019
Drydock Exam · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6620177
7 August 2018
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6490625
14 June 2017
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6175906
24 January 2017
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6075590
6 June 2016
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5899831
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 May 2025
Resolved
Provide PFDs for each person onboard. 8 adult PFDs were not provided.
Vessel limited to 122 total persons.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 14 July 2025
Resolution: All PFDs provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 20 May 2025
Resolved
Inspect watertight closures. Forepeak, eng compartment escape, aft void and lazarette hatches did not dog satisfactorily.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2025
Resolved 14 July 2025
Resolution: Hatches dogged.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 May 2025
Resolved
Inspect electrical installation. Outlet under bar was not secured and was missing faceplate
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2025
Resolved 14 July 2025
Resolution: Outlet satisfactory.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 May 2025
Resolved
Meet requirements of the FCC. Satisfactory FCC station license and Radio Safety Certificate were not provided.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2025
Resolved 14 July 2025
Resolution: FCC documents provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 June 2022
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Only 128 lifejackets found on board. Max allowable passengers are limited to 123 until 2 additional lifejackets are provided.
Action required: 705 - Other - as specified
Due 15 July 2022
Resolved 29 June 2022
Resolution: Photographic evidence of two new lifejackets porvided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 June 2022
Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name and with Type II retroflective material approved under 46 CFR 164.018 and arranged in accordance with IMO Resolution A.658(16). Replace retro on each ring buoy and mark each ring buoy with vessel's name.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2022
Resolved 29 June 2022
Resolution: Life buoys found labeled and marked correctly.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 June 2022
Resolved
A vessel on lakes, bays and sounds must carry three hand red flares and three hand orange smoke distress signals. Replace 04 expired flares.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2022
Resolved 28 June 2022
Resolution: New distress flares were purchased and satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 15 June 2022
Resolved
Emergency instructions must be mounted at the operating station and designed to address the particular equipment, arrangement, and operation of the vessel. Update emergency procedures to include vessel-specific equipment and post emergency procedures at operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2022
Resolved 28 June 2022
Resolution: Emergency instructions found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 June 2022
Resolved
Fire extinguishing equipment installed on a vessel in excess of the requirements must be designed, constructed, installed, and maintained in accordance with a recognized industry standard acceptable to the Commandant (CG-ENG-4). Replace deteriorated hose on fire extinguisher.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2022
Resolved 28 June 2022
Resolution: Hose was replaced and extinguisher was serviced.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 15 June 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Address the following items:
a) Electrical terminal exposed in lazarette.
b) Operating station aft deck lights inoperable.
c) Engine room light cover broken.
d) Three broken lights on 01 deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2022
Resolved 28 June 2022
Resolution: All electrical installations found satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 15 June 2022
Resolved
A hatch cover must have securing devices and be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Bow thruster room scuttle missing hold back device and hinge retainer. Lazarette scuttle missing hinge retainer.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2022
Resolved 28 June 2022
Resolution: Bow thruster scuttle hold back device installed and hinge retainer replaced. Lazarette scuttle hinge retainer replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 June 2022
Resolved
Abandon ship, man overboard and fire fighting drills shall be logged to include date and description. Drills were sporadically logged. Correctly log each drill (46 CFR 185.520(f) and 46 CFR 185.524(d)).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2022
Resolved 28 June 2022
Resolution: Master provided new logbook for vessel drills.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 June 2022
Resolved
At each vessel inspection all observed unsafe practices must be corrected. Black powder operations authorized per the COI are not being followed. Proper procedures, equipment, and training must be reviewed and approved by Sector Jacksonville before black powder operations can be conducted on board the vessel. (46 CFR 176.130(a))
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2022
Resolved 7 October 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 August 2021
Resolved
An adult life jacket must be provided for each person carried on board a vessel.
Found 18 adult life jackets to be non serviceable.
Vessel passenger count is reduced from 130 to 112 total persons until rectified.
46 CFR 180.71(a)
Action required: 705 - Other - as specified
Resolved 23 September 2021
Resolution: Submitted documentation clearing deficiency
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 9 August 2021
Resolved
A vessel must comply with the applicable requirements for any radio installations as set forth in 47 CFR Part 80.
Vessel radio does not have MMSI number in radio and the GPS is not interlinked.
46 CFR 184.502
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 September 2021
Resolution: Submitted documentation clearing deficiency
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 May 2020
Resolved
An adult life jacket must be provided for each person carried on board a vessel. 3 PFDs were not present.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2020
Resolved 25 June 2020
Resolution: Master provuded photo evidence of new life jackets.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 29 May 2020
Resolved
A vessel must carry up-to-date charts, Coast Pilot [name withheld] and tide tables. Pubs not up-to-date.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2020
Resolved 25 June 2020
Resolution: Master provuded photo evidence of new pubs.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 29 May 2020
Resolved
Connections must be made to battery terminals with permanent type connectors. Battery on float light not the screw type.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2020
Resolved 25 June 2020
Resolution: Master provuded photo evidence of new battery.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 29 May 2020
Resolved
A vessel must comply with applicable requirements for any radio. Expired radio station license.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2020
Resolved 27 July 2020
Resolution: Evidence provided through FCC status report that renewal was granted; vessel still awaiting delivery of certificate.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 13 May 2019
Resolved
Hatch cover must have securing devices and be attached to the hatch frame by hinges,captive chains or other devices to prevent its loss. Vessel FWD Hatch cover not secured. Secure hatch cover.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2019
Resolved 17 June 2019
Resolution: Hatch cover has new securing device installed.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 May 2019
Resolved
Portable watertight containers for
distress flares and smoke signals shall
be of a bright color, and containers
shall be clearly marked in legible contrasting
letters at least 12.7 millimeters
(0.5 inches) high: ‘‘DISTRESS SIGNALS’’.Store flares in separate water tight container.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2019
Resolved 18 June 2019
Resolution: New water tight container has been installed on vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2019
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Life ring buoy battery is past expiration date. Replace battery.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2019
Resolved 17 June 2019
Resolution: Replaced life ring buoy battery with new battery.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 13 May 2019
Resolved
A vessel must comply with appropriate FCC requirements. Vessel FCC station license is expired. Renew FCC station license.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2019
Resolved 24 May 2019
Resolution: Received copy of updated FCC station license.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 May 2019
Resolved
Vessel must carry up to date charts and publications. Vessel missing tide, current tables, light list and coast pilot. Provide publications for operational zone.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2019
Resolved 16 June 2019
Resolution: Received photos of updated and missing charts and pubs.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 13 May 2019
Resolved
Stability letter must be posted under glass or other suitable material at operating station. Post stability letter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2019
Resolved 16 June 2019
Resolution: Received photos of stability letter posted.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 May 2019
Resolved
DAPI must meet 46 CFR 16.201. Update plan as discussed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2019
Resolved 19 June 2019
Resolution: Received photo documentation of updated DAPI material.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 August 2018
Resolved
Adult jackets must be provided for all 125 adult passenger onboard. MI identified 72 damaged adult lifejackets. Vessel has been restricted to 58 adult passengers until rectified.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2018
Resolved 4 September 2018
Resolution: Recieved all PFDs. ALL SAT.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 August 2018
Resolved
Pre-engineered (FM200) fire system does not operate as designed and doesn't secure all machinery within the engine room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2018
Resolved 15 August 2018
Resolution: Tested system. TEST SAT.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 8 February 2017
Resolved
Enlose/secure access to rear side of switchboard located in the engine room.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 3 March 2017
Resolved 3 March 2017
Resolution: Photo submitted by owner showing that a panel was machined and in installed to not permit access behind the distribution panel.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 24 January 2017
Resolved
Mark/label emergency hatch located within the machinery space on interior overhead and exterior deck.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 3 March 2017
Resolved 3 March 2017
Resolution: Photo submitted showing sign constructed and placed by the emergency escape.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 6 June 2016
Resolved
Outlet box in the lazarette was missing the electrical cover. Box is in an space and isolated that does not cause an immediate shock hazard.
Condition: Improper/Lack of Maintenance
Due 14 June 2016
Resolved 14 June 2016
Resolution: Cover was replaced.
Electrical › Lighting (service) › Lighting Fixture
Issued 6 June 2016
Resolved
The lighting fixture via the aft poop deck has a missing light bulb and cover.
Due 14 June 2016
Resolved 14 June 2016
Resolution: Light bulb and cover were put in proper place.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 6 June 2016
Resolved
A small exhaust leak was found in the #3 void exhaust tubing.
Due 6 June 2016
Resolved 6 June 2016
Resolution: Corrected on the spot.
Lifesaving › Lifebuoys › Stowage
Issued 6 June 2016
Resolved
The extra (exceeds required amount) life buoy on the bridge does not have poly propleyne line aatched to it. Replace line even though it is an extra.
Due 20 June 2016
Resolved 17 June 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 June 2016
Resolved
The on board first aid kits do not have Table 15 (a)(i) list attached.
Due 20 June 2016
Resolved 17 June 2016