Records from 2009 to 2023. Most recent: inspection, 14 March 2023.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Lifesaving › Lifeboat › Hull
Issued 18 March 2009
Resolved
Starboard lifeboat damaged at port quarter. Side shell of boat is inset with fiberglass delamination on the interior. Vessel's crew had repaired with patch. Patch was found to be ineffective and interior delamination had not been addressed. Vessel's crew completed second repair of area. SOLAS 74(2004 cons) Chap III, Reg 20
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 20 March 2009
Resolution: Vessel''s crew completed fiberglass repair. Vessel''s Classification Society KR attested to satisfaction of repair.
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 18 March 2009
Resolved
Pressure vacuum valves found to be seized. Manual operation of P/V valves was not possible at time of inspection. SOLAS 74(81) Chap II-2, Reg 59.1.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 March 2009
Resolution: Vesse''s crew reworked affected valves. KR surveyor attested to proper operation of P/V valves on deck. Attending USCG inspector witnessed spot check of several valves.
Deck/Cargo › Ballast › Vents
Issued 18 March 2009
Resolved
Flame screens on the ballast tanks found to be corroded or dislodged due to corrosion product. SOLAS 74 Chap I, Reg 11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2009
Resolution: Flame screens were removed cleaned and renewed as necessary. KR surveyor attested to completion of proper repairs.
Fire Fighting › Fixed Deck Foam System › Piping
Issued 18 March 2009
Resolved
Two soft patches found on the fixed foam system in steering gear room. SOLAS 74 Chap I, Reg 11
Action required: 705 - Other - as specified
Due 18 April 2009
Resolved 14 March 2023
Resolution: Vessel has been scrapped.
Construction/Loadline › Structures › Ventilators
Issued 18 March 2009
Resolved
Vent closures found wasted or missing in the following locations: Stbd side accomodation, paint locker, halon room, steering gear, and emergency fire pump space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2009
Resolved 14 March 2023
Resolution: Vessel has been scrapped.
Engineering › Steam Boiler (auxiliary/waste heat) › Outer Casing
Issued 18 March 2009
Resolved
Lagging on the Aux boiler is wasted and falling away. SOLAS 74 Chap I, Reg 11
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 April 2009
Resolved 14 March 2023
Resolution: Vessel has been scrapped.
Construction/Loadline › Structures › Manhole
Issued 18 March 2009
Resolved
Hatch covers wasted at deck storage on portside and on engine room skylight. ICLL Chap II, Reg 16
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2009
Resolved 14 March 2023
Resolution: Vessel has been scrapped.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 March 2009
Resolved
Railing-lower course broken and missing near the stbd side embarkation area. ICLL Chap II, Reg 25
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 April 2009
Resolved 14 March 2023
Resolution: Vessel has been scrapped.
Fire Fighting › Fire Hoses › Condition
Issued 18 March 2009
Resolved
Fire hose and nozzle missing from fire station on main deck port side. SOLAS 74 Chap II-2, Reg 15
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 April 2009
Resolved 14 March 2023
Resolution: Vessel has been scrapped.
Fire Fighting › Fire Hydrants › Condition
Issued 18 March 2009
Resolved
Valve handle broken off on fire hydrant located on main deck port side under reefer installation. SOLAS 74 Chap II-2, Reg 15
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2009
Resolved 14 March 2023
Resolution: Vessel has been scrapped.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 18 March 2009
Resolved
Catwalks on main deck found to be wasted at the stbd manifold and landing near foam monitor aft of manifold. SOLAS 74 Chap I, Reg 11
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2009
Resolved 14 March 2023
Resolution: Vessel has been scrapped.
Lifesaving › Lifeboat Equipment › Anti-seasickness Medicine
Issued 18 March 2009
Resolved
Port lifeboat found to have expired sea sick pills and spoiled provisions. SOLAS 74 Chap III, Reg 11
Action required: 705 - Other - as specified
Due 18 April 2009
Resolved 14 March 2023
Resolution: Vessel has been scrapped.
Lifesaving › Lifeboat › Hull
Issued 18 March 2009
Resolved
Port lifeboat found to have dry rot on deck aft of engine compartment and fractures on the keel rail. SOLAS 74 Chap III, Reg 11
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2009
Resolved 14 March 2023
Resolution: Vessel has been scrapped.
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 18 March 2009
Resolved
Portside embarkation ladder found to have broken treads. SOLAS 74 Chap III, Reg 20.2
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 April 2009
Resolved 14 March 2023
Resolution: Vessel has been scrapped.
Engineering › Freshwater Generation System › Valve, Dump
Issued 18 March 2009
Resolved
Soft patch found on drain line near incinerator. SOLAS 74 Chap I, Reg 11
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 April 2009
Resolved 14 March 2023
Resolution: Vessel has been scrapped.