← All vessels
GUNDE MAERSK
GUNDE MAERSK is a 2007 freight ship. The Coast Guard has recorded 33 inspections since 2009, most recently in July 2026, along with 9 deficiencies and 6 operational controls.
Records from 2009 to 2026. Most recent: inspection, 16 July 2026.
- Built
- 2007
- Last inspected
- 16 July 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9359014 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
VRVO9
999387
Flag
HONG KONG
—
Maury page id
psix-999387
Inspections, by type
…with no type recorded11
Years with a record
13 calendar years (2009–2026)
The 33 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it127015 - Dead Weight, Metric Ton
0 - Displacement, Metric Ton
99002 - Convention (Subpart B), Gross Ton
57019 - Convention (Subpart B), Net Ton
0 - Displacement, Metric Ton
99002 - Convention (Subpart B), Gross Ton
57019 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 33
16 July 2026
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8439620
7 February 2026
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8308210
28 January 2026
Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8303558
8 December 2025
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8279154
23 April 2025
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8117674
23 September 2024
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8007714
12 August 2024
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8022265
18 June 2024
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7937918
24 January 2024
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7853917
7 September 2023
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7786050
16 December 2022
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7609790
10 June 2022
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7473441
23 November 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7356779
23 November 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7356784
10 December 2020
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7109780
30 September 2020
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7068398
24 April 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6943612
27 March 2019
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6650092
6 January 2019
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6606122
4 December 2017
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6317601
2 December 2016
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6051447
8 December 2015
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5777680
8 December 2015
NPV Safety Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5777908
8 December 2015
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5777941
18 September 2015
Ballast Water Examination · ISPS II Exam · NPV Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5722862
4 November 2010
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3885230
3 November 2010
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3885482
2 November 2010
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3878031
26 March 2009
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3440834
22 March 2009
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3437338
20 March 2009
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3436024
20 March 2009
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3437304
20 March 2009
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3437314
Deficiency record · 9
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 December 2025
Resolved
THE MACHINERY, BOILERS, AND OTHER VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED. PSCO OBSERVED A PIN SIZE HOLE SPRAYING WATER ON TOP OF THE REGULATING VALVE THAT REGULATES WATER FLOW FOR THE FEEDWATER SYSTEM FOR THE BOILER. 74 SOLAS (04) II-I/26.1
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 24 January 2024
Resolved
74 SOLAS (20) III/34 LSA Code 4.4.9.3
Means of identifying the ship to which the lifeboat belongs and the number of the lifeboat shall be marked in such a way that they are visible from above. PSCO observed lifeboat number on both port and starboard lifeboats were marked on port and starboard bow.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 March 2019
Resolved
Every steampipe and every fitting connected thereto through which steam may pass shall be so designed, constructed, and installed as to withstand the maximum working stress to which it may be subjected. Steam valve leading to turbine was leaking steam and condensation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 March 2019
Resolved
The arrangements for the utilization of oil in pressure lubrication systaems shall be such as to ensure the safety of the ship and persons onboard. Lubrication oil was leaking out of the first shaft bearing.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 27 March 2019
Resolved
Discharges led through the shell from within superstructures and deckhouses on the freeboard deck fitted with doors complying with the requirements of regulation 12 shall be fitted with effcient means for preventing water from passing inboard. Drain pipe in acetylene storage locker was leaking and six inches of water accumulated on deck.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 8 December 2015
Resolved
0715 - Fixed Fire Detection System - Fire detection and fire alarm systems shall be kept in good working order so as to endure their required performance if a fire occurs. Due to a fire that occured in the SSDG#1 room, the fire detection system is not operable. 74 SOLAS 14 II-2/14.2.1.1.2
Fire Fighting › Water Fog Applicators › Condition
Issued 8 December 2015
Resolved
0725 - Fixed Fire-Fighting Systems - Fire fighting systems and appliances shall be kept in good working order and readily available for immediate use. Due to a fire that occured in the SSDG#1 room, the water mist system is inoperable for all protected spaces. 74 SOLAS 14 II-2/14.2.1.2
Engineering › Diesel Engine (propulsion-direct drive) › Distributor (fuel injection)
Issued 4 November 2010
Resolved
1410 Propulsion Main Engine- Whenever a defect is discovered which effects the safety of the ship, the master shall report to the RO, who shall cause to investigate to determine if a survey is necessary. Vessel experienced fuel leak on high pressure fuel piping leading from the fuel pumps to forward supply rail. SOLAS (04cons) I Reg11(c) 60ac.
Engineering › Steam System (auxiliary) › Piping
Issued 20 March 2009
Resolved
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.