Records from 2011 to 2026. Most recent: inspection, 17 June 2026.
Documentation record
Registered dimensions (L × B × D)76.3 ft × 29.2 ft × 8.0 ft
Registered tonnagegross 91 / net 62
ITC dimensions (L × B × D)76.3 ft × 29.2 ft × 8.0 ft
ITC tonnagegross 173 / net 62
BuilderALL AMERICAN MARINE INC · BELLINGHAM, WA, UNITED STATES · built 2009
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSELDOVA, AK
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 13 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it173 - Convention (Subpart B), Gross Ton
91 - Regulatory (Subpart C or D), Gross Ton
62 - Convention (Subpart B), Net Ton
62 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 24
17 June 2026
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8408360
14 January 2026
Damage Survey · Internal Structural Exam · Drydock Exam · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8296661
16 September 2025
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8235716
11 June 2025
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8157522
11 March 2025
Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8095653
16 September 2024
Administrative Inspection · Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8003760
14 May 2024
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7912229
31 May 2023
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7704986
26 September 2022
Examination of Repairs · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7567523
26 July 2022
Type not recorded
No type recorded · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7603302
11 July 2022
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7503732
21 May 2021
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7202777
8 April 2021
Administrative Inspection · Internal Structural Exam · Examination of Repairs · Drydock Exam · Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7172246
28 April 2020
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6945892
16 May 2019
COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6684394
16 April 2019
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6664768
22 August 2018
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6519782
21 May 2018
Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6411466
22 May 2017
Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6221835
11 May 2017
Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6149561
19 April 2017
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6131715
9 September 2016
Damage Survey
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6061061
1 June 2016
Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6018542
19 May 2016
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 5999289
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 11 June 2025
Resolved
Ensure there is an appropriately valid licensed master to operate the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2025
Resolution: licensed mariner operating vsl
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 June 2025
Resolved
The port generator would not start; therefore, the pre-engineered fixed fire extinguishing system in the port engine room could not be test. Conduct proper test of port fire system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2025
Resolution: tested fire fighting sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 May 2023
Resolved
Label port/stbd aft lifejacket stowage on main deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2023
Resolved 29 June 2023
Resolution: Labelled
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 May 2023
Resolved
Renew battery in port aft second deck water light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2023
Resolved 29 June 2023
Resolution: Renewed light
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 May 2023
Resolved
Secure fire extinguisher in pantry.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2023
Resolved 29 June 2023
Resolution: secured
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 31 May 2023
Resolved
Port and stbd MSD space - label valve "DO NOT OPEN WITHIN 3 MILES OF SHORE"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2023
Resolved 29 June 2023
Resolution: labelled
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 May 2023
Resolved
Ensure waste recepticles are made of noncombustible material.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2023
Resolved 29 June 2023
Resolution: corrected
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 May 2023
Resolved
Upper deck fire hose leaks, repair or renew.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2023
Resolved 29 June 2023
Resolution: renewed
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 31 May 2023
Resolved
Place a guard on fire pump (stbd MDE) and bilge pump (port MDE)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2023
Resolved 29 June 2023
Resolution: guards added
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 July 2022
Resolved
Notified by vessel rep that fire pump was inoperable. Renew/repair fire pump. Vessel to have portable fire pump onboard until fixed fire pump is operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2022
Resolved 3 August 2022
Resolution: new fire pump installed and tested sat.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 21 May 2021
Resolved
Install missing machinery guards on the rotating machinery parts forward of both MDEs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2021
Resolved 24 July 2021
Resolution: Installed missing guards.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 21 May 2021
Resolved
Install missing machinery guards over the rotating shafts in both port and starboard hulls.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2021
Resolved 24 July 2021
Resolution: Installed missing guards.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 8 April 2021
Resolved
Port ER - Measured pit at 3/16". Hull thickness equal to 1/4". Clean P/S ER bilge and make available for inspection.
Action required: 705 - Other - as specified
Resolved 20 April 2021
Resolution: ER cleaned and ready for inspection. Found a few more suspect pits. Clad weld acceptable. Repaired.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 16 May 2019
Resolved
Provide a licensed mate onboard or a senior deckhand designation letter.
NVIC 1-91
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2019
Resolution: Received designation letter.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 16 May 2019
Resolved
Provide current publications onboard for the following:
-Coast Guard light list
-Tide Tables
-Current tables
-U.S. Coast Pilot
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2019
Resolved 23 May 2019
Resolution: all pubs are now current
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 22 August 2018
Resolved
Vsl had LR fall overboard and will replace before next operating season. Vsl pax count reduced to 106 until full compliment of primary lifesaving is provided.
Action required: 705 - Other - as specified
Resolved 23 May 2019
Resolution: 50-person liferaft has been replaced
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Marine Type Label
Issued 21 May 2018
Resolved
Fire extinguisher located at operating station needs to be upgraded to a 10 B:C.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2018
Resolved 16 May 2019
Electrical › Electric Supply System (service) › Battery Installation
Issued 21 May 2018
Resolved
Batteries located under operating station helm must be secured against excessive movement.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2018
Resolved 16 May 2019
Lifesaving › Inflatable Liferafts › Servicing
Issued 22 May 2017
Resolved
50 person Liferaft was not on the vessel at time of inspection as it was being delivered from servcing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 July 2017
Resolved 22 May 2017
Resolution: Eagle Enterprises delivered liferaft and installed correctly.
Construction/Loadline › Hull › Strut/Cross Tie
Issued 9 September 2016
Resolved
Vessel has fracture in strut.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2017
Resolution: Examined repairs to strut. Repair sat. //s// [name withheld]
Communications › Radio Communications › EPIRB
Issued 19 May 2016
Resolved
Replace expired hydrostatic release for the EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2016
Resolution: New hydrostatic release has been installed.
Communications › Alarms/Indicators › Bilge Alarm
Issued 19 May 2016
Resolved
Repair/Replace bilge pump and alarm in portside lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2016
Resolution: New pump and alarm has been installed.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 19 May 2016
Resolved
Provide FCC bridge to bridge certificate.
Action required: 705 - Other - as specified
Due 19 June 2016
Resolved 1 June 2016