NEW SOLUTION is a 2009 tank ship. The Coast Guard has recorded 11 inspections since 2009, most recently in February 2024, along with 5 deficiencies — 2 with no resolution recorded —.
Records from 2009 to 2024. Most recent: inspection, 26 February 2024.
The 11 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Share this recordDownload vessel cardDownload QRMaury, US Coast Guard vessel record for NEW SOLUTION, retrieved 18 September 2026. mauryrecords.com/v/psix-999465.html
Documentation record
Tonnage as PSIX records it321300 - Dead Weight, Ton 364050 - Displacement, Ton 162198 - Regulatory (Subpart C or D), Gross Ton 162198 - Convention (Subpart B), Gross Ton 112192 - Regulatory (Subpart C or D), Net Ton 112192 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 11
26 February 2024PSC B · COC-TVE Renew
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7864952
5 November 2019Ballast Water Examination · ISPS II Exam · Deficiency Check · Administrative Inspection · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6842669
16 March 2018Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6364308
13 October 2017COE-Administrative
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6287050
13 April 2017ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6121445
25 February 2016COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5814410
11 February 2012Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4241358
17 September 2010COE-Offshore
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3851457
13 September 2010Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3849197
13 September 2010COC-TVE Renew · Ballast Water Examination · ISPS I Exam · MARPOL Annex I Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3849262
22 March 2009COC-TVE Renew · PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3436601
14104 "Oil filtering equipment refered to in paragraph 2 of this regulation shall comply with paragraph 6 of this regulation. In addition, it shall be provided with alarm arrangements to indicate when this level cannot be maintained. The system shall also be provided with arrangements to ensure that any discharge of oily mixtures is automatically stopped when the oil content of the effluent exceeds 15 ppm. In considering the design of such equipment and approvals, the administration shall have regard to the specification recommended by the Organization." The oil content meter seal was broken. MARPOL 73/78 I/14
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 26 March 2024 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 February 2024Resolved
07199 - "In tankers, electrical cables shall not be installed in hazardous areas unless it conforms to standards acceptable to the organization." Electrical cable sealant pulled out of wire on #4 cargo pump in cargo pump room. Cable should be gas tight. 74 SOLAS (04) II-1 / 45.10
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 February 2024
Resolved 26 February 2024
Resolution: Resolved on site.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 26 February 2024No resolution recorded
06199 - "Each vessel vapor connection must have a stud and it must be located on the top of the flange face." Port/Fwd vapor flange stud located at 10 o clock position. 46CFR39.2001(J)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2024 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 November 2019Resolved
Stairways and lift trunks which penetrate more than a single deck shall be surrounded by at least "A-0" class divisions and be protected by self-closing doors at all levels. "Food Lift" from Galley, which penetrates two decks, leading to the Dry-Provision Room, is not fitted with self-closing devices. Doors are labeled as A-class self-closing doors on the Fire Control Plan and on the physical door in the Galley, but not labeled in the Dry-Provision Room. 74 SOLAS (14) II-2/ 9.2.3.4.1.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2019
Resolved 7 November 2019
Resolution: Class survey report provided with pictures verifing deficiencies have been corrected.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 November 2019Resolved
Doors required to be self-closing shall not be fitted with hold-back hooks. Numerous A-class and B-class fire doors throughout the Accommodation, which are labeled as self-closing according to the Fire Control Plan, are fitted with hold-back hooks. 74 SOLAS (14) II-2/ 9.4.2.2.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 November 2019
Resolved 7 November 2019
Resolution: Class survey report provided with pictures verifing deficiencies have been corrected.