MAURY USCG vessel records
← All vessels

BBC KIMBERLEY

BBC KIMBERLEY is a 2009 freight ship. The Coast Guard has recorded 20 inspections since 2016, most recently in July 2026, along with 6 deficiencies and 2 operational controls.

Records from 2016 to 2026. Most recent: inspection, 27 July 2026.

Built
2009
Last inspected
27 July 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 July 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9407586
999597
Flag
ANTIGUA AND BARBUDA
Maury page id
psix-999597

Documentation record

Tonnage as PSIX records it15493 - Displacement, Metric Ton
10340 - Dead Weight, Metric Ton
8750 - Convention (Subpart B), Gross Ton
3859 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 20

27 July 2026 Explosive Handling Operation-Commercial
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8448968
3 February 2026 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8305332
8 April 2025 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8108012
1 April 2025 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8103153
20 December 2023 PSC B · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7840978
8 March 2023 Explosive Handling Operation-Commercial
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7643052
28 April 2022 PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7438044
11 April 2022 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7428999
13 January 2022 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7377484
20 October 2021 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7336163
7 October 2021 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7328189
6 October 2021 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7327818
6 October 2021 COE-Offshore
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7327841
12 May 2021 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7199170
13 November 2019 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6854777
18 July 2019 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6754374
28 April 2019 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6671774
3 March 2018 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6365469
20 February 2018 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6354248
17 November 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6043271

Deficiency record · 6

10 - Safety of Navigation › N/A - No Subsystem › Pilot ladders and hoist/pilot transfer arrangements
Issued 13 January 2022 Resolved
All pilot ladders used for transfer shall be clearly identified with tags or other permanent marking so as to enable identification of each appliance for the purposes of survey, inspection and record keeping. PSCO noted certificates presented do not match the serial numbers on the pilot ladders.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2022
Resolved 11 April 2022
Resolution: RCVD report and pictures attesting to approved ladders placed onboard
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 7 October 2021 Resolved
A fixed storage tank having sufficient capacity to recharge at least one power actuating system including the reservoir. Port State Control Officer observed hydralic stroage tank empty. 74 SOLAS (04)II-1/29.12.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 October 2021
Resolved 18 October 2021
Resolution: Master provided delivery receipt for hydraulic fluid, dated one day after exam.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 7 October 2021 Resolved
Oil fuel pipes having a capacity of 500L and above shall be fitted with a cock or valve directly on the tank capable of being closed from a safe postion outside the space. Port State Control Officer observed the fuel stop valve for the emergency generator enclosed with a bolted plate and not easily accessible. 74 SOLAS (20) II-2/4.2.2.3.4
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 7 October 2021
Resolved 7 October 2021
Resolution: Chief engineer removed bolted plate and installed a quick easy access wing nut to allow for readily accessible use of the fuel cutoff valve in the event of a fire.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 October 2021 Resolved
Fire protection systems and fire-fighting systems shall be properly tested and inspected. Port State Control Officer observed portable fire extinguishers in the engine room and emergency generator room missing inspection dates for the monthly checks. Some were intialed in August and others in June. 74 SOLAS (20) II-2/14.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 October 2021
Resolved 7 October 2021
Resolution: Chief mate and Second Officer provide log book showing fire extinguishers had been checked.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 7 October 2021 Resolved
In meeting the requirements of 10.1, The company shall ensure that inspections are held at appropiate intervals. Ships Procedures JHL 21 REV 23 Form CE 06 (2.2 and 2.5) Requires inspection of emergency generator quick closing valves. Section 4.2.3 requires portable FFE monthly inspections to be recorded in logbook. Multiple portable extinguishers in engine room weren't inspected and there were no ships procedures provided on how to inspect portable FFE. Deficiencies #2 and #3 are objecting evidence of a failure of SMS. An internal audit is required with a focus on FFE and critical equipment inspection records and procedures, provide record of audit results to [email withheld] 74 SOLAS (14) IX/3.1 ISM Code 10.2.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 January 2022
Resolved 11 April 2022
Resolution: RCVD copy of company Internal SMS audit with findings.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 13 November 2019 Resolved
74 SOLAS (2014) II-2/10.1.1 FSS Code 3.2.1.1.1 Fire-fighter's outfits shall comply with the Fire Safety Systems Code. Personal equipment shall consist of the following: protective clothing of material to protect the skin from the heat radiating from the fire and from burns and scalding by steam. The aluminum outer layer of both fire fighter's outfits were deteriorated. 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2019
Resolution: Received class report of satisfactory replacement of fire suits.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.