BBC KIMBERLEY is a 2009 freight ship. The Coast Guard has recorded 20 inspections since 2016, most recently in July 2026, along with 6 deficiencies and 2 operational controls.
Records from 2016 to 2026. Most recent: inspection, 27 July 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it15493 - Displacement, Metric Ton 10340 - Dead Weight, Metric Ton 8750 - Convention (Subpart B), Gross Ton 3859 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 20
27 July 2026Explosive Handling Operation-Commercial
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8448968
10 - Safety of Navigation › N/A - No Subsystem › Pilot ladders and hoist/pilot transfer arrangements
Issued 13 January 2022Resolved
All pilot ladders used for transfer shall be clearly identified with tags or other permanent marking so as to enable identification of each appliance for the purposes of survey, inspection and record keeping. PSCO noted certificates presented do not match the serial numbers on the pilot ladders.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 February 2022
Resolved 11 April 2022
Resolution: RCVD report and pictures attesting to approved ladders placed onboard
A fixed storage tank having sufficient capacity to recharge at least one power actuating system including the reservoir. Port State Control Officer observed hydralic stroage tank empty.
74 SOLAS (04)II-1/29.12.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 October 2021
Resolved 18 October 2021
Resolution: Master provided delivery receipt for hydraulic fluid, dated one day after exam.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 7 October 2021Resolved
Oil fuel pipes having a capacity of 500L and above shall be fitted with a cock or valve directly on the tank capable of being closed from a safe postion outside the space. Port State Control Officer observed the fuel stop valve for the emergency generator enclosed with a bolted plate and not easily accessible.
74 SOLAS (20) II-2/4.2.2.3.4
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 7 October 2021
Resolved 7 October 2021
Resolution: Chief engineer removed bolted plate and installed a quick easy access wing nut to allow for readily accessible use of the fuel cutoff valve in the event of a fire.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 October 2021Resolved
Fire protection systems and fire-fighting systems shall be properly tested and inspected. Port State Control Officer observed portable fire extinguishers in the engine room and emergency generator room missing inspection dates for the monthly checks. Some were intialed in August and others in June.
74 SOLAS (20) II-2/14.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 October 2021
Resolved 7 October 2021
Resolution: Chief mate and Second Officer provide log book showing fire extinguishers had been checked.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 7 October 2021Resolved
In meeting the requirements of 10.1, The company shall ensure that inspections are held at appropiate intervals.
Ships Procedures JHL 21 REV 23 Form CE 06 (2.2 and 2.5) Requires inspection of emergency generator quick closing valves. Section 4.2.3 requires portable FFE monthly inspections to be recorded in logbook. Multiple portable extinguishers in engine room weren't inspected and there were no ships procedures provided on how to inspect portable FFE.
Deficiencies #2 and #3 are objecting evidence of a failure of SMS. An internal audit is required with a focus on FFE and critical equipment inspection records and procedures, provide record of audit results to [email withheld]
74 SOLAS (14) IX/3.1
ISM Code 10.2.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 January 2022
Resolved 11 April 2022
Resolution: RCVD copy of company Internal SMS audit with findings.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 13 November 2019Resolved
74 SOLAS (2014) II-2/10.1.1
FSS Code 3.2.1.1.1
Fire-fighter's outfits shall comply with the Fire Safety Systems Code. Personal equipment shall consist of the following: protective clothing of material to protect the skin from the heat radiating from the fire and from burns and scalding by steam. The aluminum outer layer of both fire fighter's outfits were deteriorated. 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2019
Resolution: Received class report of satisfactory replacement of fire suits.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.