MAURY USCG vessel records
← All vessels

CENTENNIAL SAPPORO

CENTENNIAL SAPPORO is a 2008 tank ship. The Coast Guard has recorded 29 inspections since 2016, most recently in March 2023, along with 4 deficiencies and 3 operational controls.

Records from 2016 to 2023. Most recent: inspection, 21 March 2023.

Built
2008
Last inspected
21 March 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 March 2023
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9387255
999700
Flag
PANAMA
Maury page id
psix-999700

Documentation record

Tonnage as PSIX records it110448 - Dead Weight, Metric Ton
127833 - Displacement, Metric Ton
59671 - Convention (Subpart B), Gross Ton
33400 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 29

21 March 2023 PSC B · COC-TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7650399
4 April 2022 COC-TVE Annual · PSC B · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7416527
29 November 2021 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7358487
20 June 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7230259
29 March 2021 PSC B · COC-TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7161561
9 March 2020 COC-TVE Annual · PSC C
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6921078
19 March 2019 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6642792
26 January 2019 COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6615372
25 September 2018 COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6548369
17 August 2018 Bulk Liquid Transfer Monitor
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6515056
10 July 2018 COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6473896
27 March 2018 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6379810
9 March 2018 Deficiency Check · Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6364850
30 January 2018 COE-Dockside
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6342955
30 January 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6346225
3 November 2017 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6300489
14 June 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6175818
10 June 2017 COE-Administrative
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6173231
7 April 2017 Administrative Inspection · COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6119832
23 March 2017 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6110240
26 January 2017 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6077955
21 December 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6060950
9 December 2016 COE-Dockside
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6052133
25 August 2016 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5984082
23 August 2016 COE-Administrative
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5980900
7 August 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5964886
12 June 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5904790
23 April 2016 COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5860680
20 January 2016 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5800444

Deficiency record · 4

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 4 April 2022 Resolved
Where the atmosphere in double hull spaces cannot be reliably measured using flexible gas sampling hoses, such spaces shall be fitted with permanent gas sampling lines. the configuration of gas sampling lines shall be adapted to the design of such spaces. the M/T Centennial Sapporo utilizes the RIKEN KEIKI RM-950 Gas Sampling system to achieve this requirement. During the gas sampling portion of the exam, the [name withheld] stated to PSCOs that "they are only required to test gas sampling alarm set points with span gas on a monthly basis, they do not calibrate sensors." The Vessel's Safety Management System refers gas sampling system maintenance and calibration to the manufacturer's manual, which states "it is necessary to perform gas sampling system gas calibration every 6 months." Cite: 74SOLAS(20) II-2/4.5.7.22 Action taken: 50bc
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2022
Resolved 21 April 2022
Resolution: Received satisfactory internal analysis + audit documentation. Documentation includes evidence of proper fixed gas sampling calibration and updated calibration procedures to be completed onboard.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 4 April 2022 Resolved
The Company should identify equipment and technical systems, the sudden operational failure of which may result in hazardous situations. The vessel's Safety Management System refers gas sampling system maintenance and calibration requirements to the manufacturer's manual, which states "it is necessary to perform gas calibration every 6 months, using required calibration equipment." PSCOs identified that the last recorded span gas calibration was 27AUG2021. Vessel is currently outside required calibration window. In addition, after review of the vessel's planned maintenance system records - specificially task code OFF_000VY, gas sampling system span gas calibration took place onboard up until February 2021, after this time/date, sensor calibration ceased with no recorded change in planned maintenance system procedures. The vessel operator is required to perform an internal audit and analysis of the vessel's safety Management System focusing on the fixed gas sampling system maintenance and calibration cycle. Provide proposed corrective actions to the USCG by 04MAY2022. Cite: 74SOLAS(20) IX/3.1 - ISM Code 10.3 Action taken: 50bc
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2022
Resolved 21 April 2022
Resolution: Received satisfactory internal analysis + audit documentation. Documentation includes evidence of proper gas sampling calibration, updated PMS procedures and completion of crew training.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 4 April 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisons of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCOs observed excessive oil soaked lagging encasing the cargo pump room stripping pump. Cite: 74SOLAS(20) I/11 Action taken: 10c
Action required: 10 - Deficiency Rectified
Due 4 April 2022
Resolved 4 April 2022
Resolution: Crew removed oil soaked lagging and replaced after visual inspection of stripping pump fittings and seals to confirm continued safe operation.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Lighting
Issued 9 March 2018 Resolved
0599 - In tankers, electrical equipment, cables and wiring shall not be installed in hazardous locations unless it conforms with standards not inferior to those acceptable to the organization. PSCO found 07 explosion-proof/flame proof light in hazardous areas(06 in pumproom, 01 in SOPEP locker) with cracks in housing. PSCOs found 14 additional lights where threaded stuffing tube fittings could be loosened by hand. This provides objective evidence that the lighting does not meet IGC 60092--502 requirements. 74 SOLAS (2014) II-1/45.11 50ac - removed COC from vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2018
Resolved 27 March 2018
Resolution: Received class report (see documents tab) that indicated the replacement of 10 explosion proof lights.

Ownership record