Inspection record

Last inspected 21 May 2026
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 14 calendar years (2013–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1001089
Flag
UNITED STATES
Tonnage
25239 - Convention (Subpart B), Gross Ton 22515 - Regulatory (Subpart C or D), Gross Ton 16186 - Convention (Subpart B), Net Ton 48041 - Dead Weight, Ton 22515 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-1001089
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. Only barges and towing vessels are in this archive, so any other vessel type in the same activity does not appear here: these lists are a floor, not a complete manifest.

LIBERTY Towing Vessel · MISLE 875954 · 17 April 2020 · activity 6942707LEGEND Towing Vessel · MISLE 1047213 · 17 April 2020 · activity 6942707INDEPENDENT Towing Vessel · MISLE 1433719 · 17 April 2020 · activity 6942707LEGEND Towing Vessel · MISLE 1047213 · 2 December 2019 · activity 6867447LEGEND Towing Vessel · MISLE 1047213 · 27 November 2019 · activity 6868888

Inspection history · 34

21 May 2026 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8378142
24 April 2026 MARPOL Annex VI Survey · MARPOL Annex I Examination · Annual Inspection · MTSA Verification
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8355341
6 March 2026 Bulk Liquid Transfer Monitor
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8320858
27 May 2025 Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8128867
7 February 2025 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8076325
3 June 2024 Administrative Inspection · Deficiency Check · Periodic Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7925792
17 February 2024 Bulk Liquid Transfer Monitor
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7867035
23 January 2024 Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7853405
12 June 2023 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7701603
29 August 2022 Administrative Inspection · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7542737
15 July 2022 Administrative Inspection · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7507764
10 February 2022 In-Service Inspection · Administrative Inspection · Examination of Repairs · Cargo Tank Internal · Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7388550
27 August 2021 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7296509
27 August 2020 Periodic Inspection · MTSA Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7043782
17 April 2020 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6942707
2 December 2019 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6867447
27 November 2019 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6868888
21 September 2019 Bulk Liquid Transfer Monitor
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6817324
12 September 2019 Ballast Water Examination · MARPOL Annex VI Survey · Annual Inspection · MARPOL Annex I Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6808120
9 April 2019 Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6665525
9 August 2018 MARPOL Annex VI Survey · MARPOL Annex I Examination · MARPOL Annex II Examination · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6504905
23 July 2018 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6488421
31 July 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6226328
25 July 2017 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6221411
31 March 2017 MARPOL Annex I Examination · MARPOL Annex II Examination · COI Inspection · MARPOL Annex VI Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6113651
14 March 2017 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6088264
22 November 2016 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6050055
4 August 2016 Annual Inspection · MARPOL Annex II Examination · MARPOL Annex VI Survey · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5956659
30 June 2016 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5924780
9 September 2015 Annual Inspection · MARPOL Annex VI Survey · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5233281
5 January 2015 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5047859
29 December 2014 Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5045481
7 August 2014 MTSA/ISPS Verification · MARPOL Annex I Examination · MARPOL Annex VI Survey · Administrative Inspection · Periodic Inspection · Ballast Water Examination · MARPOL Annex II Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4938834
7 August 2013 MARPOL Annex VI Survey · Annual Inspection · MARPOL Annex I Examination · MARPOL Annex II Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4665476

Deficiency record · 16

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 May 2025 Resolved
Through runs of marine shipboard cable meeting subpart 111.60 of this part are required for all hazardous locations. MI observed a broken frayed wire to lighting on the cargo manifest in a hazardous zone. 46CFR 111.105-17(a) 10c
Action required: 10 - Deficiency Rectified
Due 27 May 2025
Resolved 27 May 2025
Resolution: Vessel repaired the frayed wire.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 June 2024 Resolved
The tank overfill alarm required by paragraph (a) of this section must activate a visible and audible alarm so that it can be seen and heard on the vessel where cargo transfer is controlled and in the cargo deck area. Overfill alarm #2 port cargo tank was not working. Repair prior to loading cargo. 46 CFR 39.2007(d)(3)
Action required: 705 - Other - as specified
Due 11 June 2024
Resolved 12 June 2024
Resolution: Bergen technicians attended the vessel and repaired overfill alarm for #2P cargo tank.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 11 June 2024 Resolved
Each fixture in the weather or in a location exposed to splashing water must be watertight. MI identified multiple lighting fixtures on deck with standing water in the bulbs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 18 June 2024
Resolution: Fixtures were examined and found with no moisture and secured as designed and considered satisfactory.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 12 June 2023 Resolved
Scantlings, material, and workmanship, subdivision of cargo spaces, fitting of cofferdams, and testing of tanks shall be at least equivalent to the requirements of ABS or other recognized classification society. 1 ventilation closure device for port generator space found missing locking device and unable to be sealed properly with two middle locking devices. Thermal fluid heater space found missing locking device on ventilation closure. 46 CFR 32.60-1(a)
Action required: 10 - Deficiency Rectified
Due 12 June 2023
Resolved 12 June 2023
Resolution: Crew corrected both ventilation closures by adding one locking device each closure and readjusted port generator space ventilation closure showing proper closing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 July 2022 Resolved
MIs received notification of an inoperable IGGS blower. Repair or replace blower IAW with the submitted repair proposal. 46 CFR 32.53-5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 August 2022
Resolved 15 August 2022
Resolution: Vessel rep provided ABS survey with repairs and testing. All Sat. Def Resolved.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 21 March 2022 Resolved
The inspection for certification shall include an inspection of the machinery and equipment. The inspection shall ensure the vessel is in satisfactory condition and fit for service. ODME valve local indicator found to be in frozen condition during operational test. 46 CFR 31.10-15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2022
Resolved 25 April 2022
Resolution: Received proof satisfactory operational test of local ODME valve indicator.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 August 2021 Resolved
All distribution valves and controls shall be of an approved type. All controls shall be suitably protected. Pull cable protective piping for the fixed CO2 system covering the starboard generator space found to be wasted away near passageway between generator space and thermal fluid heater room. The remaining protective piping was found to be resting on the pull cable, thus applying pressure to the line and leaving the pull cable exposed. Marine inspectors unable to determine integrity of the cable from the corrosive environment. 46 CFR 34.15-10(d)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2021
Resolved 7 September 2021
Resolution: Third party serviced fixed CO2 system. Replaced pull cables for the cylinder and valve lines servicing the thermal fluid heater room and the cylinder pull cable for the stbd generator space. Also, protective piping replaced in exposed areas.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil fuel tank protection
Issued 27 August 2021 Resolved
The high-level indicating device must-(1) Indicate visually the level of liquid used in the cargo tank when the liquid level is within a range of 1 meter (3.28 feet) of the top of the tank. #6P cargo tank 1 meter stick found to be in a frozen condition. 46 CFR 39.2003(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2021
Resolved 7 September 2021
Resolution: Received video from operator showing free motion in both upward and downward direction.
14 - Pollution Prevention › 142 - MARPOL Annex II › Vent. Procedures/equipment
Issued 27 August 2021 Resolved
Double flame screens of 20 x 20 corrosion resistant wire mesh with a 1//2-inch corrosion-resistant separator or a single screen of 30 x 30 corrosion-resistant wire mesh shall be fitted on all openings to atmosphere. Vapor main pressure/vacuum valve wire mesh on vacuum side found to be painted over. 46 CFR 162.017-3 (n)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2021
Resolved 7 September 2021
Resolution: Received pictures showing that the paint has been removed from the flame screen.
14 - Pollution Prevention › 142 - MARPOL Annex II › Vent. Procedures/equipment
Issued 27 August 2021 Resolved
Double flame screens of 20 x 20 corrosion-resistant wire mesh with a 1//2-inch corrosion-resistant separator or a single screen of 30 x 30 corrosion-resistant wire mesh shall be fitted on all openings to atmosphere. Pressure/vacuum valve for #7P cargo tank had vacuum side housing wasted away, resulting in no flame screen installed. 46 CFR 162.017-3 (n)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 August 2021
Resolved 27 August 2021
Resolution: New vacuum side assembly installed with new flame screen.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 27 August 2021 Resolved
Each duct for ventilation of category A machinery spaces that passes through accommodation, service, or control spaces must be: (2) constructed of steel, fitted with an automatic fire damper at each boundary where it enters and leaves the Category A machinery space. Ventilation duct damper found to be missing above the Inert Gas Generator. 46 CFR 32.56-60(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 August 2021
Resolved 27 August 2021
Resolution: New damper installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 August 2021 Resolved
Systems of the type indicated in 34.15-5(d) shall be actuated at each station by one control operating the valve to the space and a separate control releasing at least the required amount of carbon dioxide. These two controls shall be located in a box or other enclosure clearly identified for the particular space. Pull cable signage outside of IGG space found to be painted over. 46 CFR 35.10-15(d)
Action required: 10 - Deficiency Rectified
Due 27 August 2021
Resolved 27 August 2021
Resolution: Signage cleaned to be fully legible.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 31 March 2017 Resolved
Could not verify proper operation of the inert gas generator. Prior to carrying cargoes that require inerting, provide tech report of cause of fault, correction, proper operation, and that all required tests of alarms/shutdowns were performed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 31 March 2017
Resolution: Received tech report from Instruments & Controls Inc. stating proper operation of IGS and all alarms/shutdowns were tested.
Engineering › Pressure Vessel › Safety Valve
Issued 31 March 2017 Resolved
Could not test safety relief valves on air receivers. Provide proof of bench test or new installation of safety relief valves on air receivers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 6 April 2017
Resolution: Received receipts for two 150 psi safety relief valves for air receivers.
Engineering › Pressure Vessel › Pressure Gauge
Issued 31 March 2017 Resolved
Gauges on air receivers stop at 200 psi, MAWP of the pressure vessel is 200 psi. Replace gauges with gauges that show 1.2 x MAWP of the pressure vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 6 April 2017
Resolution: Received statement of installation of 300 psi gauge on each air receiver.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 31 March 2017 Resolved
Marine Inspector noted paint was stored in the same room as thermal fluid heater (TFH), with installed CO2 system. Have company provide proposal for paint storage that meets applicable CFR requirements.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 6 April 2017
Resolved 13 April 2017
Resolution: Vessel provided receipts of purchase and installation of on-deck fire-proof lockers to paint storage.