Records from 2016 to 2026. Most recent: inspection, 9 April 2026.
Inspection history · 29
9 April 2026
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8345173
20 January 2026
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8298389
10 July 2025
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8182501
19 May 2025
PSC B
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8137302
5 May 2025
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8128941
10 February 2025
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8077140
12 August 2024
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7979828
11 August 2024
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7978681
19 June 2024
PSC B · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7937434
5 June 2024
Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7929278
31 May 2024
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7923847
7 June 2022
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7470738
7 April 2022
Ballast Water Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7426289
29 March 2022
PSC A
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7421059
15 January 2022
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7380884
10 January 2022
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7377894
13 August 2021
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7286182
3 July 2020
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6994460
24 June 2020
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6985521
16 March 2020
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6926026
13 March 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6925951
13 March 2020
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6926022
12 March 2020
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6925268
27 February 2020
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6911431
19 November 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6309563
19 November 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6312714
15 November 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6307708
30 May 2017
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6159784
15 May 2016
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5871100
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 19 May 2025
Resolved
The opening below the lowest course of the guard rails shall not exceed 230mm (9 inches). The other course shall be not more than 380mm (15 inches) apart. In the case of ships with rounded gunwhales the guard rails support shall be placed on the flat of the deck.
ICLL 66/25.3
There was a horizontal guard railing on the starboard side detached from the stantion. As well as another horizontal guard rail that was bent, no longer meeting the spacial requirements.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 July 2025
Resolved 10 July 2025
Resolution: Recived Class Report attesting to repairs.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 19 June 2024
Resolved
In meeting these requirements, the company should ensure that any non-conformities is reported with its possible cause, if known. No report of non-conformity has been made for the following deficiencies. Based on the following deficiencies as objective evidence, and an expanded ISM exam, an external audit is required.
74 SOLAS (20) IX/3.1 ISM 10.2.2
30ac
Action required: 30 - Ship detained
Due 19 June 2024
Resolved 22 June 2024
Resolution: Vessel's Flag and Ship Management provided corrective action to the satisfaction of SEC SENE.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 June 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel’s No. 3 fuel tank 6” pipe at the engine room forward bulkhead found with a cement patch, wet with fuel oil.
74 SOLAS (20) I/11(a) 30ac
Action required: 30 - Ship detained
Due 19 June 2024
Resolved 22 June 2024
Resolution: Deficiency re-issued as 40AC.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 June 2024
Resolved
In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the fuel oil shall be such to ensure the safety of the ship and persons on board, and shall at least comply with the following provisions. Vessel’s Main Engine fuel leak piping found with approximately 5 feet of pipe missing. Crew has installed a clear plastic hose to drain fuel from pipe to collection point. Pipe was removed and hose installed at dry dock, 08 APR 2024.
Action required: 30 - Ship detained
Due 19 June 2024
Resolved 22 June 2024
Resolution: Vessel located and re-installed the original piping to the satisfaction of Class and Coast Guard.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 June 2024
Resolved
The construction of doors and door frames in A class division, with the means of securing them when closed, shall provide resistance to fire as well as the passage of smoke. PSCO observed A-60 self-closing doors compromised with holes and compromised latches on A-deck port and starboard doors to embarkation. Stairwell door on A-deck has compromised latch. B-deck aft port door to ladder well has compromised latch. C-deck aft starboard door to ladder well is hard to open. Steering gear room door does not self close. A-60 door on boiler top has compromised latch. Upper-deck A-60 self-closing door missing
latch assembly.
74 SOLAS (04) II-2/9.4.1.1.2
30ac
Action required: 30 - Ship detained
Due 19 June 2024
Resolved 22 June 2024
Resolution: Vessel effected repairs to the satisfaction of Class and Coast Guard.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 June 2024
Resolved
Door required to be self-closing shall not be fitted with hold-back hooks. Paris MOU PSC Exam on 15 MAY 2024 identified “several self closing fire doors… equipped with hold-back hooks.” The crew submitted documentation to the PSC that “all areas to be checked by safety officer,” and the deficiency was cleared. During current USCG PSC Exam, found 02 additional self-closing doors (B-deck, House entrance Port & Starboard) to be fitted with hold-backs.
74 SOLAS (04) II-2/9.4.2.2
30ac
Action required: 30 - Ship detained
Due 19 June 2024
Resolved 22 June 2024
Resolution: Vessel effected repairs to the satisfaction of Class and Coast Guard.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 19 June 2024
Resolved
The machinery, boilers and other pressure vessels… shall be so installed and protected to reduce to a minimum any danger to persons on board. Auxiliary Boilers No. 1 relief valve found arranged with lifting handle improperly aligned. If the attached cable was pulled, the handle would be pulled towards the closed position, in lieu of opening.
74 SOLAS (04) II-1/26.1
60ac
Action required: 60 - Rectify deficiencies prior to movement
Due 19 June 2024
Resolved 22 June 2024
Resolution: Vessel effected repairs to the satisfaction of Class and Coast Guard.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 19 June 2024
Resolved
A duplicate set of fire control plans or a booklet containing such plans shall be permanently stored in a prominently marked weather tight enclosure outside the deck house for the assistance of shore-side fire-fighting personnel. Fire control plan located at Port and Starboard gangway do not match the fire control plans inside the ship; specifically the slop chest door and the upper deck Engine Room changing room/Engine Room entrance.
74 SOLAS (04) II-2/15.2.4.2
60ac
Action required: 60 - Rectify deficiencies prior to movement
Due 19 June 2024
Resolved 22 June 2024
Resolution: Vessel provided correct, class endorsed copies to the satisfaction of Class and Coast Guard.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 June 2024
Resolved
The Administration may permit the use of oil-level gauges with flat glasses and self-closing valves between the gauges and fuel tanks (arrangements for lube oil shall at least comply with 2.2.3.5). Cylinder O Measuring Tank and S-T L.O. Head tank found with zip ties holding self-closing valves open.
74 SOLAS (04) II-2/4.2.2.3.5.2.2
10c
Action required: 10 - Deficiency Rectified
Due 19 June 2024
Resolved 19 June 2024
Resolution: Rectified on board by ships crew to satisfaction of PSCO
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 19 June 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel’s No. 3 fuel tank 6” pipe at the engine room forward bulkhead found with a cement patch, wet with fuel oil.
Re-Issued as 40AC after release from 30AC.
74 SOLAS (20) I/11(a) 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 22 June 2024
Resolved 19 August 2024
Resolution: class survey attached.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 April 2022
Resolved
For any vessel that is equipped with ballast water tanks and bound for ports in the U.S. submit the ballast water report no later than 6 hours after arrival. Vessel did not submit ballast water report until prompted by the USCG, Aprox 49 hours after arrival. 33 CFR 151.1060(b)(3) 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 April 2022
Resolved 7 April 2022
Resolution: Observed print out of report sent to the NBIC during the exam.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 29 March 2022
Resolved
Each survival craft shall be stowed in a state of continous readiness so that two crew memebers can carry out preparations for embarkation and launching in less than 5 minutes. Portside lifeboat unable to be lowered in 5 minutes; lifeboat lowered in 20 minutes. Crew last lowered lifeboat on 08MAR2022, crew excessively greased the falls and drum 22MAR2022.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 March 2022
Resolved 7 April 2022
Resolution: Re-engaged with Class. Proper function and maintenance ensured. Def cleared.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 29 March 2022
Resolved
Every crewmember with assigned emergency duties shall be famliar with these duties before the voyage begins. PSCO observed fire team unfamiliar with operation of equipment including energizing flashlights, properly securing the SCBA, and donning firefighting outfits.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 29 March 2022
Resolved 29 March 2022
Resolution: Second-Mate gave on-the-spot training to firefighters on proper use of equipment. Firefighter demonstrated proper use to PSCO.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 27 February 2020
Resolved
DOORS REQUIRED TO BE SELF-CLOSING SHALL NOT BE FITTED WITH HOLD-BACK HOOKS. HOWEVER, HOLD-BACK ARRANGEMENTS FITTED WITH REMOTE RELEASE DEVICES OF THE FAIL-SAFE TYPE MAY BE UTILIZED. PSCO OBSERVED SELF CLOSING DOORS FROM ENGINE ROOM LEADING TO STEERING GEAR ROOM PROPPED OPEN. PROVIDE CORRECTIVE ACTION PLAN FROM COMPANY WITH CONCURRENCE FROM ADMINISTRATION.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 March 2020
Resolved 13 March 2020
Resolution: MSD Panama City Recieved Email confirming rectification of Deficiency
Operations/Management › Drills/Instruction › Fire
Issued 30 May 2017
Resolved
Drills shall, as far as practicable, be conducted as if there were an actual emergency. Crew demonstrated a lack of competency during the fire drill; 02 crew were unable to properly don their firefighter outfit and missing key equipment: firemans axe. 01 Crewmember had fire pants situated as to expose him to potential flames. SOLAS 2014 (Cons.) III/Reg. 19.3.1 10c
Action required: 705 - Other - as specified
Due 30 May 2017
Resolved 30 May 2017
Resolution: Training was implemented by the PSCO on lifeline handling, donning firemans pants, and donning firemans axes. Reccommended further drills for the crew.
Construction/Loadline › Structures › Door
Issued 30 May 2017
Resolved
Doors fitted in boundary bulkheads of category A shall be resonably gastight and self-closing. 02 doors in the engine room did not close of their own accord after opening. SOLAS 2014 (Cons.) II-2/ Reg. 9.4.2.1 10c
Action required: 705 - Other - as specified
Resolved 30 May 2017
Resolution: Adjustments were made to allow the doors to functionally close by themselves.