Records from 2005 to 2023. Most recent: inspection, 17 January 2023.
Inspection history · 23
17 January 2023
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7622852
25 September 2020
COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7056331
2 January 2020
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6882281
23 October 2019
Deficiency Check · Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6840748
17 October 2019
Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6836196
25 October 2018
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6567701
2 November 2017
Drydock Exam · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6299912
22 December 2016
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6061491
6 December 2016
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6035491
30 October 2015
Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5758947
28 September 2015
DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5732095
26 October 2014
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5013169
26 October 2014
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5015306
17 June 2014
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4894380
3 May 2012
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4301392
3 May 2012
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4301409
3 May 2012
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4301417
29 January 2012
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4234506
16 February 2011
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3946824
3 September 2010
Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3841344
23 October 2008
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3349144
30 October 2007
Administrative Inspection · Annual Inspection · Hull Examination · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3085716
24 February 2005
Deficiency Check · Plan Review "T" Boat · Initial Certification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2298637
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 25 September 2020
Resolved
The construction and arrangement of a vessel must allow the safe operation in accordance with their COI. Marine inspectors identified a fracture in the FRP on the starboard side in the middle of the engine compartment. The fracture is located where the horizontal stiffener meets the bottom hull. Submit a repair proposal for approval prior to carrying out the repairs. 46CFR177.100
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 October 2020
Resolution: Attended vessel to witness satisfactory repairs of crack in FRP on the starboard frame within the engine compartment.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 September 2020
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with §80.59 once every five years. The vessel's Communications Act Safety Radiotelephony Certificate is expired. 47CFR80.903
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 October 2020
Resolution: Attended vessel and was provided valid Safety Radiotelephony Certificate.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 September 2020
Resolved
To enhance protection of life and property it is mandatory that each 406.0-406.1 MHz EPIRB be registered with NOAA before installation and that information be kept up-to-date. The EPIRB registration that is on-board the vessel does not match the EPIRB that is on-board the vessel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 October 2020
Resolution: Attended vessel and was provided a valid EPIRB registration that matched the EPIRB on board the vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 October 2019
Resolved
Vessel must be operated in accordance with applicable laws and regulations. Parachute launch pedestal base is cracked allowing water to enter into wood core, clean at base of parachute guidepost –corrosion between aluminum and stainless steel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2019
Resolved 31 October 2019
Resolution: Aluminum pedestal base refinished, corrosion between aluminum and stainless steel cleaned and rebeded, and fractured area reglassed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 23 October 2019
Resolved
Hull penetrations within 6 inches from waterline shall have a positive action valve or cock located close to the hull. 2 drain holes do not have required valves.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 November 2019
Resolved 31 October 2019
Resolution: Valves installed as required.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 17 October 2019
Resolved
The construction and arrangement of a vessel must allow the safe operation IAW COI. A FRP crack propagating into hull in forward portion of the engineroom with undeterminable depth causing concern for structural strength and watertight integrity. Submit a repair proposal for approval prior to carrying out the repairs. Prior to determination and approved repairs made, vessel cannot operate in commercial service.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2019
Resolved 23 October 2019
Resolution: Area of concern was determined to be cosmetic when the area was taken down to FRP.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 17 October 2019
Resolved
The construction and arrangement of a vessel must allow the safe operation IAW COI. A small amount of fine wood pulp found in forward compartment associated with termite invasion. Submit a repair proposal for approval/acceptance prior to remedying the condition.
Action required: 705 - Other - as specified
Due 14 November 2019
Resolved 31 October 2019
Resolution: Renewed with new wood core and reglassed.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 17 October 2019
Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2)
VHF radio missing LAT/LONG for DSC operation.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2019
Resolved 23 October 2019
Resolution: VHF has LAT/LONG input along with MMSI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 October 2019
Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. Replace wing nut with permanently installed nut.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2019
Resolved 23 October 2019
Resolution: Hex nuts installed in place of wing nuts.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 17 October 2019
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Maintain written documentation and follow requirements per ASTM F-3099-19, Standard Practice for Parasailing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 November 2019
Resolved 31 October 2019
Resolution: Vessel has required inspection program.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 November 2017
Resolved
Remove dead end electrical wiring throughout vessel.
Action required: 705 - Other - as specified
Due 6 December 2017
Resolved 14 December 2017
Resolution: Removed as required.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 November 2017
Resolved
Secure wiring every 24" as high above the bilge as practicable using metal type fastners.
Action required: 705 - Other - as specified
Due 6 December 2017
Resolved 14 December 2017
Resolution: Wiring mounted off of bilge as required.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 November 2017
Resolved
Complete credit drydock per COI requirement.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2017
Construction/Loadline › Structures › Deck Plating
Issued 6 November 2017
Resolved
Provide repair proposal for holes in deck where captains chair was removed. After approval of plans, complete repair to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 6 December 2017
Resolved 14 December 2017
Resolution: Vessel completed satisfactory repairs.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 6 December 2016
Resolved
COD is expired. Prior to operation, provide new COD to attending CG MI. 46 CFR 67.7
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 December 2016
Resolved 6 December 2016
Resolution: Vessel captain provided emailed copy from vessel owner. Reminded vessel captain that actual COD had to be onboard prior to carrying passengers.
Lifesaving › Lifebuoys › Serviceable
Issued 6 December 2016
Resolved
Ring life buoy is wasted with several large cracks; vessel's name was not marked on RLB and retro tape is faded. Renew RLB in accordance with 46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 22 December 2016
Navigation › Piloting/Steering › Marine Charts
Issued 6 December 2016
Resolved
Nav chart is of whole Hawaiian islands. Provide up to date chart of Malama Bay operating area large enough for safe operation. 46 CFR 184.420
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 22 December 2016
Engineering › Sea-water System (primary cooling) › Piping
Issued 6 December 2016
Resolved
Raw water hose in steering compartment is dry rotted. Remove and replace raw water hose. 46 CFR 182.710
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 22 December 2016
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 6 December 2016
Resolved
Negative grounding wire on battery terminal is corroded. Replace grounding wire in accordance with original lectrical plans. 46 CFR 183.354
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 22 December 2016
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 6 December 2016
Resolved
Electric fuel valve in aft steering space is no longer in use. Remove electric fuel valve and associated wiring.
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 22 December 2016
Operations/Management › Drills/Instruction › Fire
Issued 6 December 2016
Resolved
Emergency instructions do not reflect actual operations. Ex: Emergency instructions in the event of a fire call to turn on fire pumps but vessel is not equipped with a fire pump. Update emrgency instructions to reflect actual o[perations and crew training. 46 CFR 185.510
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 22 December 2016
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 6 December 2016
Resolved
Retro tape is wasted on 11 adult and 1 child lifejacket. Renew retro tape on 11 adult and 1 child lifejacket with SOLAS approved tape. 46 CFR 185.604
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 22 December 2016
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 6 December 2016
Resolved
Auxiliary means of steering was inoperable. Prior to carrying passengers, prove proper operation of secondary means of steering. 46 CFR 182.620(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 January 2017
Resolved 6 December 2016
Resolution: Emergency tiller was machined. Vessel captain and crew demonstrated proper operation of auxiliary means of steering.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 6 December 2016
Resolved
Training and drill log not up to date. Provide up to date traning and drill log. 46 CFR 185.520
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 22 January 2017
Resolution: Closed in separate def check activity 6061491
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 28 September 2015
Resolved
No current or tide tables onboard
Action required: 705 - Other - as specified
Due 15 October 2015
Resolved 29 September 2015
Resolution: Have tide and current tables onboard
Personnel › Training › Familiarization Training
Issued 28 September 2015
Resolved
No onboard logs for training or maintenance.
Action required: 705 - Other - as specified
Due 15 October 2015
Resolved 29 September 2015
Resolution: Have created logs to document training and maintenance.
Engineering › Bilge Water Management System › Interface Detector
Issued 28 September 2015
Resolved
Provide proof of working visual indicator at operating station for automatic bilge pump.
Action required: 705 - Other - as specified
Due 15 October 2015
Resolved 22 December 2016
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 28 September 2015
Resolved
Repair forward stbd vent closure.
Action required: 705 - Other - as specified
Due 15 October 2015
Resolved 29 September 2015
Resolution: Vent closure repaired.
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 28 September 2015
Resolved
Fill pre-engineered fixed gas firefighting system to manufacturer's specifications.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 October 2015
Resolved 29 September 2015
Resolution: Pre-engineered fixed firefighting system repaired.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 28 September 2015
Resolved
Provide proof of servicing for both extinguishers.
Action required: 705 - Other - as specified
Due 15 October 2015
Resolved 29 September 2015
Resolution: Both extinguishers serviced.
Engineering › Steering Gear System › Valve
Issued 26 October 2014
Resolved
Demonstrate proper steering to the satisfaction of the attending CG inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2014
Resolution: Attended vessel and verified proper steering.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 21 October 2008
Resolved
Provide proof of automatic engine shutdown with discharge of fixed fire extinguishing system. Also provide engine start override switch for fixed fire extinguishing system.
Action required: 705 - Other - as specified
Due 21 November 2008
Resolved 10 November 2008
Resolution: Installed engine start override switch and proved proper operation of automatic shut down and override switch for fixed fire extinguishing system.
Engineering › Fuel Oil Service System › Hose
Issued 21 October 2008
Resolved
Replace all fuel and hydraulic lines, in excess of 30 inches, with approved flexible hose with compression type connection fittings.
Action required: 705 - Other - as specified
Due 21 November 2008
Resolved 10 November 2008
Resolution: Replaced all fuel and hydraulic lines with approved compression fitted hoses.
Fire Fighting › Fire Bucket › Quantity
Issued 30 October 2007
Resolved
Provide 3rd 2.5 gallon fire bucket with lanyard. 46CFR181.610
Condition: Improper/Lack of Maintenance
Due 1 November 2007
Resolved 31 October 2007
Resolution: Sightred correct quantity of buckets on vessel.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 October 2007
Resolved
Provide complete first aid kit. 46CFR184.710 Note: Provided master with listing of items required in a first aid kit.
Due 1 November 2007
Resolved 31 October 2007
Resolution: Sigted updated items for the first aid kit.
Fire Fighting › Ventilation Systems › Ducts
Issued 30 October 2007
Resolved
Clean out plugged stbd fuel tank vent. 46CFR182.460
Due 1 November 2007
Resolved 31 October 2007
Resolution: Sighted cleaned out fuel tank vent assembly.
Construction/Loadline › Hull › Hull Plating
Issued 23 October 2007
Resolved
Vessel must complete credit dry-dock prior to carrying passengers.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 October 2007
Resolved 31 October 2007
Resolution: Completed credit drydock.