Records from 2004 to 2026. Most recent: inspection, 11 March 2026.
Inspection history · 14
11 March 2026
Deficiency Check · Annual Inspection · Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8324770
2 April 2025
Deficiency Check · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8103704
1 March 2024
Drydock Exam · Initial Certification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7872333
9 September 2020
Drydock Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7044374
3 January 2020
Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 6882515
2 January 2020
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6882312
13 June 2019
DAPI Audit · COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6703775
28 May 2019
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6697515
20 September 2018
Deficiency Check · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6544879
6 February 2018
Deficiency Check · COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6350670
28 March 2017
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6112693
13 February 2017
Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6081330
1 February 2017
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6081350
15 April 2016
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5855081
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 11 March 2026
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Alcohol swabs not installed on board during inspection. 46 CFR 4.06-15
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2026
Resolution: New alcohol swabs installed
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 March 2026
Resolved
Portable extinguishers must be inspected and maintained in accordance with NFPA 10 for annual maintenance and recharging of extinguishers. For fixed gas fire extinguishing systems the owner must provide satisfactory evidence of the required servicing to the marine inspector. Portable fire extinguishers and pre-engineered fixed gas extinguisher (Fireboy) installed on vessel exceed the annual servicing requirements. Provide annual servicing records for fireboy and portable fire extinguishers installed on the vessel. 46 CFR 176.810(b)(1)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2026
Resolution: Fire servicing records provided
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 March 2026
Resolved
A vessel of more than 26 feet in length, but not more than 65 feet, must carry a minimum of one life buoy of not less then 24 inches in diameter. 31ft vessel carries one 20" ring buoy. Provide one 24" ring buoy installed on vessel as required. 46 CFR 180.70(a)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2026
Resolution: 24" ring buoy installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 March 2026
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. 10 Marlin Type 1 life jackets installed on vessel (Model 320RT for Adults and Model 321RT for Child size) have a malfunctioning spring-loaded tab on the snap hook of the safety strap. The
spring-loaded tabs fail to spring back,(return to closed position) after depressing to secure snap hook in place. Renewal required for all affected Lot #'s. Vessel has 05 serviceable adult life jackets, therefore passenger count shall be reduced to 03 adult passengers until affected life jackets are replaced with serviceable Type 1 life jackets. 46 CFR 176.808(b)
Action required: 705 - Other - as specified
Resolved 6 April 2026
Resolution: 10 New adult life jackets provided
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 2 April 2025
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Alcohol swabs not installed on board during inspection. 46 CFR 4.06-15
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2025
Resolution: New Alcohol swabs installed onboard vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 April 2025
Resolved
Each vessel required to have a Certificate of Inspection is subject to the annual vessel inspection fee listed in table 2.10-101 for its vessel category. The vessel owner or operator must pay the annual vessel inspection fee each year on or before the vessel's user fee anniversary date. Owner required to pay outstanding user fees. 46 CFR 2.10-101
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2025
Resolved 7 April 2025
Resolution: Paid receipt of User Fees provided. All sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 March 2024
Resolved
The construction and arrangement of a vessel must allow the safe operations of the vessel in accordance with the terms of the COI giving consideration to provisions for a seaworthy hull, protections against fire, means of escape in case of sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Vessel does not have structural approval for Partially Protected Route. Provide structural approval for new route.
46 CFR 177.100
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 May 2024
Resolution: Uploaded approved letter.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 June 2019
Resolved
Each life ring buoy on a vessel must be approved in accordance with 160.050 in subchapter Q of this chapter or other standard specified by the commandant; Line attached lifering buoy is frayed; Replace life ring buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2019
Resolved 26 June 2019
Resolution: Ring buoy replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 13 June 2019
Resolved
A hatch exposed to the weather must be watertight; Hatch leading into the engine room is not watertight. Gasket is loose and bedding of hatch has holes which will lead to water dripping into space. Repair hatch to make watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2019
Resolved 26 June 2019
Resolution: Hatch repaired to make watertight.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 June 2019
Resolved
Connections must be made to battery terminals with permanent type connectors; port side battery terminals connectors are not permanent; remove wing nuts from battery and make connectors permanent.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2019
Resolved 26 June 2019
Resolution: Wing nuts removed; permanent connections in place.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 June 2019
Resolved
Placards container instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers; vessel does not have proper donning instructions for two lifejackets that are of a different type; post donning instructions on vessel
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2019
Resolved 26 June 2019
Resolution: Donning instructions for all types of lifejackets posted.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 June 2019
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards including fire, caused by or originating in electrical equipment, and electrical shock; vessel's positive battery cable for starboard battery is deteriorated; replace starboard battery cable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2019
Resolved 26 June 2019
Resolution: Battery cable replaced in kind.
Electrical › Electric Supply System (service) › Cable
Issued 8 February 2018
Resolved
Prove proper operation of main engine ignition switch IAW 46 CFR 182.200(a).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2018
Resolution: Proved proper operation of main engine ignition switch.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 8 February 2018
Resolved
Complete DAPI audit IAW 46 CFR 16.
Action required: 705 - Other - as specified
Due 8 March 2018
Resolved 28 February 2018
Resolution: DAPI audit complete.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 28 March 2017
Resolved
Upon discharge, fireboy audible and visual alarm inoperable. Provide audible and visual alarm at operating station to indicate discharge. 46CFR 181.420(b)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 4 April 2017
Resolved 27 April 2017
Resolution: Witnessed operational test of fireboy system and operational audible and visual alarm at operating station.
Communications › Alarms/Indicators › Bilge Alarm
Issued 28 March 2017
Resolved
Visual indicator for operation of automatic bilge pump is missing. Provide a visual indicator at the operating station to indicate operation. 46CFR 182.530(c)
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 April 2017
Resolved 27 April 2017
Resolution: Visual indicator for operation of automatic bilge pump was installed and operational.
Navigation › Piloting/Steering › Marine Charts
Issued 28 March 2017
Resolved
Provide up to date navigational chart for operating area 46CFR 184.420
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 April 2017
Resolved 27 April 2017
Resolution: Updated nav chart for operational area provided. LNM: 04/22/17
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 28 March 2017
Resolved
Provide up to date current and tide tables, coast pilot, 2017 light list for operating area. 46CFR 184.420
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 April 2017
Resolved 27 April 2017
Resolution: 2017 light list, coast pilot for Hawaiian Islands, and updated current/tide tables provided.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 28 March 2017
Resolved
Lifejacket donning placard does not match the type of lifejackets on board. Provide donning placard to match life jackets. 46CFR 185.518
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 3 June 2017
Resolution: Vessel operator emailed photo of donning placard.
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 March 2017
Resolved
Remove dead-end wires in console to minimize accidental contact with energized parts. 46CFR 183.200(c)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 April 2017
Resolved 27 April 2017
Resolution: Dead end wires under console removed.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 February 2017
Resolved
Drydock exam due date exceeded; must complete credited dry dock exam prior to carrying pax.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2017
Resolution: Drydock completed.
Navigation › Piloting/Steering › Marine Charts
Issued 15 April 2016
Resolved
Provide updated navigation charts.
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 4 April 2017
Resolution: Verified nav charts
Electrical › Electric Generation Source (emergency) › Neutral Ground
Issued 15 April 2016
Resolved
Demonstrate proper electrical bond to a common ground from port side fuel tank.
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 4 April 2017
Resolution: Verified electrical bond to a common ground.
Engineering › Lubricating Oil Service System › Hose
Issued 15 April 2016
Resolved
Replace fuel suction hoses IAW 46CFR 182.720(e)
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 4 April 2017
Resolution: Replaced fuel suction hoses.
Engineering › Bilge Water Management System › Piping
Issued 15 April 2016
Resolved
Provide visual indicators for bilge alarms in the pilot house in order to identify each compartment. 46CFR182.530
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 4 April 2017
Resolution: Provided indicators.
Engineering › Sea-water System (primary cooling) › Piping
Issued 15 April 2016
Resolved
Provide double clamps for salt water hoses. 46CFR182.410
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 4 April 2017
Resolution: Verified double clamps.