MAURY USCG vessel records
← All vessels

MSC YORK VII

MSC YORK VII is a 2000 freight ship. The Coast Guard has recorded 34 inspections since 2016, most recently in February 2026, along with 11 deficiencies and 8 operational controls.

Records from 2016 to 2026. Most recent: inspection, 26 February 2026.

Built
2000
Last inspected
26 February 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the tow units and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 February 2026
…with no type recorded7
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9196838
1012612
Flag
LIBERIA
Maury page id
psix-1012612

Documentation record

Tonnage as PSIX records it41490 - Convention (Subpart B), Net Ton
81583 - Dead Weight, Metric Ton
107762 - Displacement, Metric Ton
74661 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

34 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; 8 operational controls with the dates imposed and removed; 1 vessel inspected with it, by name and date; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CAPT JIMMY T MORAN Towing Vessel · MISLE 971798 · 11 April 2016 · activity 5860205

Inspection history · 34

26 February 2026 PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8317109
24 September 2023 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7792385
9 June 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7710725
26 April 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7675931
29 March 2023 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7653616
14 December 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7608708
6 September 2022 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7547793
12 January 2022 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7375014
9 May 2021 Ballast Water Examination · Deficiency Check · PSC B · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7192528
4 March 2021 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7150203
18 December 2020 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7113769
21 October 2020 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7079814
6 May 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6948438
2 May 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6947273
1 May 2020 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6946759
25 September 2019 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6816430
22 April 2019 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6667418
8 April 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6658319
3 March 2019 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6631536
3 August 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6497844
24 June 2018 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6453538
19 June 2018 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6449504
4 May 2018 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6405778
29 October 2017 Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6296853
5 June 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6166693
3 April 2017 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6114450
29 September 2016 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6012436
6 September 2016 Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5992599
29 August 2016 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5986874
27 August 2016 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5984499
21 May 2016 In-Service Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5882611
11 April 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5851150
11 April 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5860205
9 February 2016 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5812104

Deficiency record · 11

14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management Plan (BWMP)
Issued 9 May 2021 Resolved
To discharge ballast water into the waters of the United States, the master, owner, operator, agent or person in charge of a vessel subject to 151.2025 of this subpart must either ensure that the ballast water meets the ballast water discharge standard in 151.2030(a), use an AMS as described in 151.2025(a)(3), or ballast with water from a U.S. public water system, according to the schedule in paragraph (b) of this section. Subject vessel, of keel laid date 17NOV1999 and ballast water capacity of 19654 m3, is past its compliance date per the implementation schedule in 33 CFR 151.2035 (b). Vessel’s current ballast water management method is exchange and discharge, which is not authorized. Vessel has no BWTS installed.Vessel is not authorized to discharge untreated ballast into U.S. waters. This deficiency will not be cleared until CG examiners receive documentation that the vessel has installed a BWTS, has decided to use on public water from the U.S. public water system, or has updated its ballast water management plan to state that the vessel’s ballast water management method in U.S. waters is no discharge.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 12 May 2021
Resolution: 12MAY21 PSC received satisfactory updates to BWMP for operations in US and proof of Liberia flag approval.
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management Plan (BWMP)
Issued 9 May 2021 Resolved
A vessel equipped with ballast water tanks that operates in the waters of the United States must maintain a ballast water management plan that has been developed specifically for the vessel and that will allow those responsible for the plans implementation to understand and follow the vessel's ballast water management strategy and comply with the requirements of this subpart.Vessel’s ballast water management plan does not reference the must up-to-date version of 33CFR151 Subpart D.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 May 2021
Resolution: 12MAY21: PSC received updates to Ballast Water Managment Plan appendix II and updated record of revisions page and approval from Liberia Flag.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 3 March 2019 Resolved
07126 -The porpuse of this regulation is to limit the growth potential in every space. means of control for flammable liquid tranfer pipe form pump to purifing room has leak. Crew had 2 drip pan caughting oil that was leaking form a flang. SOLAS 2004 11-2 reg 5.1.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 April 2019
Resolution: Class witnessed repairs effected to the flange where oil was leaking.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 3 March 2019 Resolved
13197-After survey of the ship under this regulation has been completed no changes shall be made in structual arrangement. Tank locaed in purifiing room quick closing valve was no connected. Solas 2004 1/11.a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 April 2019
Resolution: Class attested to the connection of the quick-closing valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 August 2018 Resolved
1420- 74 SOLAS (04) II-1/ 26.7- Provisions shall be made to facilitate cleaning inspection and maintenance of main propulsion and auxilary machinery. PSCO observed oily rags and containers with oil scattered throughout the engine room.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2018
Resolved 4 August 2018
Resolution: Class report submitted to clear the oil found around the engine room
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 3 August 2018 Resolved
1410- 74 SOLAS (01) II-2/ 15.2- The arrangements for the distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. PSCO observed excesive fuel oil located on the vacinity of the #8 cylinder injector valve.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2018
Resolved 4 August 2018
Resolution: Class report submitted to clear the oil found around the engine room.
Engineering › Diesel Engine (propulsion-direct drive) › Valve, Pilot (air start)
Issued 29 October 2017 Resolved
THE MACHINERY SYSTEMS AND FITTINGS SHALL BE ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED. THE DESIGN SHALL HAVE REGARD TO MATERIALS USED FOR THH PURPOSE FOR WHICH THE EQUIPMENT IS INTENDED. THE VESSEL COULD NOT MAINTAIN PROPULSION WHILE ATTEMPTING TO GET UNDERWAY FROM BAYPORT CONTAINER TERMINAL. 74SOLAS(2001) II-1/26
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 29 October 2017
Resolved 31 October 2017
Resolution: Received, reviewed and accepted class report from class, BV, stating the deficiency was rectified.
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 6 September 2016 Resolved
1430-Auxiliary engines-The condition of the ship and its equipment shall be maintained to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed fuel oil leaking from the low pressure fuel rail on #1 and #4 generators. Generators shall not be used until proof of repair has been provided. SOLAS 14 I/11 16a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 September 2016
Resolved 29 September 2016
Resolution: PSC NOLA received a class report from BV stating that the leaks have been repaired.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 6 September 2016 Resolved
1410-Propulsion main eng-The condition of the ship and its equipment shall be maintained to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed what appears to be several exhaust leaks on the turbo on the vessels main engine. Provide clarification from class as to the integrity of the exhaust system SOLAS 14 I/11 16a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 September 2016
Resolved 29 September 2016
Resolution: PSC NOLA received a class report from BV stating that all exhaust leaks have been repaired.
Operations/Management › Pollution › Removal Methods/Procedures
Issued 6 September 2016 Resolved
2120-Garbage-Every ship of 400 GT and above shall carry a garbage management plan which the crew shall follow. This plan shall provide written procedures for collecting, storing, processing and disposing of garbage. PSCO observed excessive storage of oily rags in plastic bags in the engine room. Garbage management plan does not provide instruction for the storage of excess oily rags. MARPOL V/9 16
Action required: 705 - Other - as specified
Due 20 September 2016
Resolved 29 September 2016
Resolution: PSC NOLA received a class report from BV stating that oily rags were removed and additional bins identified as hazardous material were provided in proper storage locations and amended the garbage management plan.
Engineering › Steering Gear System › Power Unit
Issued 21 May 2016 Resolved
0936-Steering Gear-The condition of the ship and its equipment shall be maintained to conform with the provisions of regulation to ensure the ship will remain fit to proceed to sea without danger to the ship or persons on board. Steering gear system No.1 follow up mode is not operational. '74 SOLAS ('14 Cons.) CH.I/Reg.11A; 17AC
Action required: 17 - Rectify deficiencies prior to departure
Due 21 May 2016
Resolved 21 May 2016
Resolution: Technitians report indicates that a power control board was found defective and was replaced. Class verified operation.

Ownership record