Records from 2010 to 2025. Most recent: inspection, 4 November 2025.
Documentation record
Registered dimensions (L × B × D)222.0 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,208 / net 1,208
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCONRAD SHIPYARD LLC · MORGAN CITY, LA, UNITED STATES · built 2010
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 July 2026 · expires 31 August 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1208 - Simplified, Gross Ton
1208 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 21
4 November 2025
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8263969
23 May 2025
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8142413
10 February 2025
In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8075544
4 February 2025
Internal Structural Exam · Examination of Repairs · COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8067101
6 April 2022
Periodic Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7417459
8 March 2021
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7152226
23 December 2019
Examination of Repairs · Internal Structural Exam · MTSA Verification · Drydock Exam · Cargo Tank Internal · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6872499
22 April 2019
Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6667839
14 January 2019
Periodic Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6610214
2 May 2018
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6449526
1 February 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6347708
23 February 2017
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6091823
25 January 2017
Annual Inspection · MTSA Verification
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6076471
18 December 2015
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5794753
17 November 2014
MTSA Verification · Internal Structural Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5021904
27 June 2014
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4897293
10 June 2013
MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4611836
26 July 2012
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4391148
29 June 2012
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 4360983
12 July 2011
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4078599
3 February 2010
Administrative Inspection · Initial Certification · MTSA Verification · COI Inspection · Internal Structural Exam · Drydock Exam · Hull Examination · Construction Oversight · Cargo Tank Internal
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3674599
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 6 April 2022
Resolved
All machinery associated with cargo loading, unloading, or cooling shall be capable of being shut down from a remote location. The Marine Inspector (MI) observed the air pressure gauge for the emergency shut down at the midpoint of the starboard side was cracked and the gauge for the emergency shut down at the aft end of the starboard side was not legible. Replace and confirm the proper operation of emergency shut offs prior to loading cargo.
Cite: 46 CFR 38.15-20(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2022
Resolved 12 April 2022
Resolution: Gauges were replaced with new gauges. Witnessed satisfactory testing of emergency shutdowns and testing of the quick closing valves IAW 46 CFR 38.10-1(j).
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 6 April 2022
Resolved
The cargo tank safety relief valves shall be inspected at least once in every 2 years. The MI observed the paperwork for the testing of the safety relief valves was not on board.
Cite: 46 CFR 38.25-10(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2022
Resolved 11 April 2022
Resolution: Testing paperwork provided and matches the photo of testing tag.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 6 April 2022
Resolved
All valves, flanges, fittings, and accessory equipment shall be of a type suitable for use with liquefied flammable gases, and shall be made of steel or grade A malleable iron, acceptable for the service temperature of part 56 of subchapter F of this chapter. The MI observed both the paperwork for the testing / suitability of the gauges and the safety relief valves on the piping were not on board. Replace or provide documentation.
Cite: 46 CFR 38.10-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2022
Resolved 11 April 2022
Resolution: All valves replaced and testing paperwork provided for safety relief valves.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 25 January 2017
Resolved
Port liquid and Port Vapor quick closing shut off valves do not meet requirements. Port liquid valve does not activate and port vapor valve exceeds 10 second closing time requirement. As per 46 CFR 151.20-5(f) quick closing shutoff valves shall operate from full open to full close under all service conditions in not more than 10 seconds without causing excessive pressure surges.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 February 2017
Resolved 23 February 2017
Resolution: Faulty regulators that supply air to valves were replaced. All liquid and vapor quick closing shut off valves close within 10 seconds.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Relief Valve
Issued 18 December 2015
Resolved
Safety relief valve was found set at 265 PSI and cargo tank MAWP was 260 PSI. Safety relief valves must be set to relieve at or below cargo tank MAWPs. Proceed to discharge cargo, but do not load until relief valves with settings of 260 PSI or less are tested and installed to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 January 2016
Resolved 24 February 2016
Resolution: Attended resetting of all safety relief valves to MAWP or less and witnessed satisfactory testing.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 29 June 2012
Resolved
Emergency shutdowns not working on upper center Cargo header port and stbd side. Tag out center cargo headers, offload Cargo via Stern Cargo Header. Prove proper operation of emergency shutdown on center cargo header to attending Coast Guard Marine Inspector prior to loading next Cargo.
Action required: 705 - Other - as specified
Due 29 July 2012
Resolved 26 July 2012
Resolution: Witnessed shut down of all pneumatic valves.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 29 June 2012
Resolved
Alarm panel shows alarm and alarm is not sounding. Prove proper operation of alarm panel and horn to the satisfaction of attending Coast Guard Marine Inspector prior to loading next Cargo.
Action required: 705 - Other - as specified
Due 29 July 2012
Resolved 26 July 2012
Resolution: Witnessed proper operation of panel and alarms