1208 - Simplified, Gross Ton
1208 - Simplified, Net Ton
Maury page id
psix-1016358
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. Only barges and towing
vessels are in this archive, so any other vessel type in the same activity does not
appear here: these lists are a floor, not a complete manifest.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 6 April 2022Resolved
All machinery associated with cargo loading, unloading, or cooling shall be capable of being shut down from a remote location. The Marine Inspector (MI) observed the air pressure gauge for the emergency shut down at the midpoint of the starboard side was cracked and the gauge for the emergency shut down at the aft end of the starboard side was not legible. Replace and confirm the proper operation of emergency shut offs prior to loading cargo.
Cite: 46 CFR 38.15-20(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2022
Resolved 12 April 2022
Resolution: Gauges were replaced with new gauges. Witnessed satisfactory testing of emergency shutdowns and testing of the quick closing valves IAW 46 CFR 38.10-1(j).
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 6 April 2022Resolved
The cargo tank safety relief valves shall be inspected at least once in every 2 years. The MI observed the paperwork for the testing of the safety relief valves was not on board.
Cite: 46 CFR 38.25-10(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2022
Resolved 11 April 2022
Resolution: Testing paperwork provided and matches the photo of testing tag.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 6 April 2022Resolved
All valves, flanges, fittings, and accessory equipment shall be of a type suitable for use with liquefied flammable gases, and shall be made of steel or grade A malleable iron, acceptable for the service temperature of part 56 of subchapter F of this chapter. The MI observed both the paperwork for the testing / suitability of the gauges and the safety relief valves on the piping were not on board. Replace or provide documentation.
Cite: 46 CFR 38.10-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2022
Resolved 11 April 2022
Resolution: All valves replaced and testing paperwork provided for safety relief valves.
Port liquid and Port Vapor quick closing shut off valves do not meet requirements. Port liquid valve does not activate and port vapor valve exceeds 10 second closing time requirement. As per 46 CFR 151.20-5(f) quick closing shutoff valves shall operate from full open to full close under all service conditions in not more than 10 seconds without causing excessive pressure surges.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 February 2017
Resolved 23 February 2017
Resolution: Faulty regulators that supply air to valves were replaced. All liquid and vapor quick closing shut off valves close within 10 seconds.
Safety relief valve was found set at 265 PSI and cargo tank MAWP was 260 PSI. Safety relief valves must be set to relieve at or below cargo tank MAWPs. Proceed to discharge cargo, but do not load until relief valves with settings of 260 PSI or less are tested and installed to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 January 2016
Resolved 24 February 2016
Resolution: Attended resetting of all safety relief valves to MAWP or less and witnessed satisfactory testing.
Emergency shutdowns not working on upper center Cargo header port and stbd side. Tag out center cargo headers, offload Cargo via Stern Cargo Header. Prove proper operation of emergency shutdown on center cargo header to attending Coast Guard Marine Inspector prior to loading next Cargo.
Action required: 705 - Other - as specified
Due 29 July 2012
Resolved 26 July 2012
Resolution: Witnessed shut down of all pneumatic valves.
Alarm panel shows alarm and alarm is not sounding. Prove proper operation of alarm panel and horn to the satisfaction of attending Coast Guard Marine Inspector prior to loading next Cargo.
Action required: 705 - Other - as specified
Due 29 July 2012
Resolved 26 July 2012
Resolution: Witnessed proper operation of panel and alarms