MAURY USCG vessel records
← All vessels

MSC ILLINOIS VII

MSC ILLINOIS VII is a 2000 freight ship. The Coast Guard has recorded 47 inspections since 2016, most recently in December 2025, along with 30 deficiencies and 13 operational controls.

Records from 2016 to 2025. Most recent: inspection, 15 December 2025.

Built
2000
Last inspected
15 December 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9197545
1021662
Flag
LIBERIA
Maury page id
psix-1021662

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded10
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it74583 - Convention (Subpart B), Gross Ton
41490 - Convention (Subpart B), Net Ton
81462 - Dead Weight, Ton
107762 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CMA CGM MOLIERE Freight Ship · MISLE 1047250 · 7 July 2017 · activity 6249881

Inspection history · 47

15 December 2025 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8283188
3 June 2025 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8150704
25 July 2024 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7967156
22 July 2024 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7964378
3 June 2024 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7926350
23 May 2024 Administrative Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7917995
22 May 2024 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7917203
12 April 2024 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7894366
21 February 2024 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7867266
26 July 2023 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7744799
18 August 2022 PSC A · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7537003
31 May 2022 ISM Exam · Deficiency Check · PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7457339
24 November 2021 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7358471
23 November 2021 MARPOL Annex VI Survey · PSC B · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7353445
14 August 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7286353
6 May 2021 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7186386
26 April 2021 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7183042
29 January 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7133080
17 January 2021 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7125827
10 December 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7109530
30 November 2020 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7106165
31 October 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7087566
20 October 2020 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7080752
20 April 2020 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6941544
10 April 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6937778
4 December 2019 In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6867001
2 August 2019 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6769852
16 June 2019 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6715416
2 March 2019 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6635197
16 December 2018 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6597358
16 July 2018 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6480978
4 June 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6433596
30 April 2018 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6405590
29 April 2018 ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam · Deficiency Check · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6401121
20 April 2018 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6395754
18 March 2018 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6374980
16 March 2018 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6373102
14 March 2018 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6371553
14 March 2018 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6371629
9 March 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6368831
7 March 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6367464
12 July 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6205523
7 July 2017 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6249881
28 June 2017 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6189486
24 July 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5950877
25 May 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5886375
1 January 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5789708

Deficiency record · 30

10 - Safety of Navigation › N/A - No Subsystem › Speed and distance indicator
Issued 3 June 2024 Resolved
10118 - Each vessel required to be fitted with an Automatic Radar Plotting Aid (ARPA) under § 164.38 of this part must be fitted with a device to indicate speed and distance of the vessel either through the water or over the ground. 33CFR164.40(a) / 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 22 July 2024
Resolved 22 July 2024
Resolution: Speed log has been replaced and vessel has received a letter from class stating that that system is fully operational and satisfactory.
14 - Pollution Prevention › 147 - Anti-Fouling › Other (AFS)
Issued 18 August 2022 Resolved
The master, owner, operator, agent, or PIC of any vessel equipped with ballast water tanks that operate in the waters of the U.S. must remove fouling organisms from the vessel's hull on a regular basis and dispose of IAW local, State, and Federal regulations. Excessive growth of algae and organisms were observed on the hull. 33 CFR 151.2050(f)
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 September 2022
Resolution: Vessel provided a Technical Report from their [name withheld] attesting to the Hull cleaning. The vessel also submitted a detailed report of the cleaning from the dive service that attended the vessel.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 August 2022 Resolved
Means shall be provided to control leaks of flammable liquids. Oil soaked lagging was observed on the No. 2 generator fuel oil supply line filter and actively leaking. 74SOLAS (01) II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 September 2022
Resolved 19 August 2022
Resolution: class survey report was recieved by the PSCDO.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 August 2022 Resolved
Whenever there is a hazardous condition onboard a vessel, the owner, agent, master, operator, or PIC shall immediately notify the nearest Coast Guard Sector. Vessel failed to report smoke condition in refrigerated container that required fire control and prevention measures that occurred while enroute to the Sector New York COTP Zone.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 18 August 2022
Resolved 18 August 2022
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 18 August 2022 Resolved
Ecery ship of 100 GT and above shall carry a garbage management plan which the crew shall follow. Oily rags were store in gree waste recepticle meant for recyclable materials, per their plan. MARPOL V/1.10.2
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 18 August 2022
Resolved 18 August 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 May 2022 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. / PSCO observed a pipe rupture in the fire main during operational test of emergency fire pump due to excessive corrosion/wastage. 74 SOLAS (2014) II-2/14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 1 June 2022
Resolution: Pipe renewed/replaced and pressure tested with class. PSCO observed successful test of hoses from bridge wing without further issue on affected area of repair or elsewhere.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 31 May 2022 Resolved
The main inlets and outlets of all ventilation systems shall be capable of being closed from outside the space being ventilated. / PSCO witnessed two crewmembers unsuccessfully attempt to close three cargo hatch ventilation closures amidships on the port side on cargo holds 3 and 4 due to improper seating, inadequate lubrication, and general lack of preventative maintenance despite having been logged as checked and in good working order three days prior. In one instance, the frame of the ventilation and adjacent hinge were deformed and no longer seating correctly. 74 SOLAS (2001) II-2/16.9
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 1 June 2022
Resolution: Dampers were lubricated and exercised. In cases where seating was improper, the covers were adjusted. All fully close.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 31 May 2022 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance in a fire occurs: structural fire protection. / PSCO observed excessive rust and corrosion on the inlet pipe to the paint locker fixed-firefighting system. Crew removed rust and repainted, exposing deep areas of pitting and wastage on the pipe. 74 SOLAS (2014) II-2/5.2.1.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 June 2022
Resolution: Area of piping renewed and vessel directed by class to include inspection of area in weekly check.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 May 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or person on board. / PSCO observed deflections on the main engine exhaust gas manifold, exposing cracks in the casing. 74 SOLAS (2014) I/11.a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 June 2022
Resolution: Area of deformed sheathing replaced and reattached satisfactorily with permanent connections.
10 - Safety of Navigation › N/A - No Subsystem › Navigation records
Issued 31 May 2022 Resolved
No person may cause a vessel to enter into or get underway on the navigable waters of the United States unless the emergency steering drill described below has been conducted within 48 hours prior to entry and logged in the vessel logbook. / PSCO observed that the required check prior to entering the navigable waters of the United States had not been logged during the previous 48 hours. PSCO also observed one of the deck officers hastily entering it after the PSCO discovered the discrepancy, under direction by the vessel’s master. 33 CFR 164.25
Action required: 10 - Deficiency Rectified
Resolved 31 May 2022
Resolution: Log was retroactively edited to reflect non-logged test that had demonstrably occured via objective evidence to PSCO
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 May 2022 Resolved
Cables and wirings shall be installed and supported in such a manner as to avoid chafing or other damage. / PSCO witnessed materially-wasted electrical outlet boxes on the weather deck which were unable to close and prevent damage to the outlets contained within. In one box, the outlet was inappropriately mounted with electrical tape. In another, the bottom hinge was completely broken off and the upper hinge was seized with rust. 74 SOLAS (2001) II-1/45.5.5
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 June 2022
Resolution: Boxes renewed and resealed.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 31 May 2022 Resolved
Efficient guard rails shall be fitted on all exposed parts of the freeboard and superstructure decks. / PSCO observed a wasted hand-rail stanchion in the port side superstructure ladder on deck “E”. ICLL 25.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 June 2022
Resolution: Handrail stanchion tubing cropped and renewed
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 31 May 2022 Resolved
Satisfactory means shall be provided for the protection of the crew in getting to and from their quarters, the machinery space, and all other parts used in the necessary work of the ship. / PSCO observed a ladder from the main deck to a cargo hold, used frequently for checking container lashing and refrigeration containers during transit, which had been broken completely in half on the bottom. ICLL 25.4 (17ac)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 June 2022
Resolution: Ladder structural member cropped and renewed.
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 31 May 2022 Resolved
To assist in casualty investigations, cargo ships, when engaged on international voyages, shall be fitted with a VDR which may be a simplified voyage data recorder (S-VDR). The S-VDR should continuously maintain sequential records of preselected items relating to the status and output of the ship’s equipment, and command and control of the ship. / PSCO witnessed an audio error and alarm relating to a malfunctioning communication input from the starboard bridge wing conning station on the VDR that the crew was unaware of. 74 SOLAS (2014) V/20.2 MSC.163(78)
Action required: 10 - Deficiency Rectified
Resolved 31 May 2022
Resolution: Electrician fixed communication channel and VDR error cleared
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 31 May 2022 Resolved
Every candidate for certification as an officer in charge of a navigational watch on ships of 500 gross tonnage or more shall be required to demonstrate the competence to undertake, at the operational level, the tasks, duties, and responsibilities listed in column 1 of table A-II/1. / PSCO witnessed the 2nd officer fail to operate the helm properly during a steering test and also was unaware of general fire-fighting safety procedures and vessel controls. STCW II/1.1
Action required: 10 - Deficiency Rectified
Resolved 31 May 2022
Resolution: Crewman was able to demonstrate task
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 31 May 2022 Resolved
Electrical installations shall be such that electrical services essential for safety will be ensured under various emergency conditions. PSCO witnessed extinguished emergency lighting on deck. 74 SOLAS (2001) 40.1.2
Action required: 10 - Deficiency Rectified
Resolved 31 May 2022
Resolution: Lightbulb was changed
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 31 May 2022 Resolved
In meeting these requirements, the company should ensure that any non-conformity is reported, with its possible cause, if known. PSCO noted the vessel failed to report several non-conformities, per vessel’s safety management system (SMS) procedures, of a technical and operational nature which collectively provide objective evidence of a serious failure or lack of effectiveness of the implementation of the ISM Code. Due to the failure of lack of effectiveness of the SMS, an external SMS audit shall be carried out. 74 SOLAS (2020) IX/3.1 ISM Code A/10.2.2
Action required: 30 - Ship detained
Resolved 1 June 2022
Resolution: DNV conducted audit of SMS resulting in 3 Non-conformities and 2 observations, due in September 2022.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 4 December 2019 Resolved
The construction and the means for securing the weathertightness of cargo and other hatchways in positions 1 and 2 shall be at least equivalent to the requirements of regulations 15 and 16 of this annex. PSCO observed forward bosun store port side hatchway showing light after being fully closed. ICLL 1966 Protocol 1988 14.1
Action required: 10 - Deficiency Rectified
Resolved 4 December 2019
Resolution: PSCO observed the seal was replaced on the door and completely closed.
12 - Dangerous Goods › N/A - No Subsystem › Dangerous goods / harmful substances in pack. form
Issued 4 December 2019 Resolved
The carriage of dangerous goods in packagted form shallb e in compliance with the relevant provisions of the IMDG Code. A cargo transport unit containing dangerous goods or residues of dangerous goods shall be clearly display placards as follows each end and each side. PSCO observed container SUDU 1898444 missing placards on one end. 74 SOLAS (a) 2014 cons VII/3 IMDG code 5.3.1.1.4.1.1
Action required: 10 - Deficiency Rectified
Resolved 4 December 2019
Resolution: PSCO observed the vessel replaced the placards with new correct placards.
12 - Dangerous Goods › N/A - No Subsystem › Dangerous goods / harmful substances in pack. form
Issued 4 December 2019 Resolved
The carriage of dangerous goods in packaged form shall be in compliance with the relevant provisions of the IMDG Code. Except for goods of class 1 the UN numbers shall be displayed as required by this chapter on consignments of : solids, liquids or gases transport units, including on each compartment of a multi-compartment tank cargo transport unit. PSCO Observed container TCLU 9401846 missing the UN Number. 74 SOLAS(a) 2014 cons VII/3 IMDG Code 5.3.2.1.1.1
Action required: 10 - Deficiency Rectified
Resolved 4 December 2019
Resolution: PSCO observed the crew make new UN numbers and placed on the container on both ends.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 3 August 2019 Resolved
Oil fuel pipes which, if damage, would allow oil to escape from a storage, settling or daily service tank having a capacity of 500/ and above...shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position from outside the space. PSCOs observed 03 closing devices located in the purifier room with the air activator hoses disconnected. Closing devices were unable to be remotely closed. 74 SOLAS 2000 consolidated CH II-1/4.2.2.3.4
Action required: 10 - Deficiency Rectified
Resolved 3 August 2019
Resolution: Hoses were reconnected correcting the deficiency and verified by PSCOs
Engineering › Bilge Water Management System › Pump
Issued 4 June 2018 Resolved
The arrangement of the Ballast Pumping System shall prevent the possibility of water passing from the sea into machinery spaces. Ballast Pumps #1 and #2 mechanical seals are leaking. 74 SOLAS 04 II-1/21.1.4
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 July 2018
Resolution: MECHANCIAL SEALS HAVE BEEN REPLACED, ATTESTED BY CLASS.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 29 April 2018 Resolved
PSCO'S OBSERVED UNSATISFACTORY TEST OF THE OWS WHEN AN OILY MIXTURE DISCHARGED FROM THE RECIRCULATION LINE WHILE THE THREE WAY VALVE WAS OPEN. AFTER FURTHER EXAM TOOL MARKS WERE OBSERVED ON THE DISCHARGE LINE FLANGE BOLTS OUTWARD OF THE THREE WAY VALVE. OIL WAS FOUND IN THE SICHARGE LINE OUTBOARD OF THE THREE WAY VALVE. MARPOL I/14.2
Action required: 30 - Ship detained
Due 30 April 2018
Resolved 2 May 2018
Resolution: See Class report.
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 29 April 2018 Resolved
PSCO'S OBSERVED OILY RAGS AND OIL SOAKED LAGGING IN THE PURIFIER ROOM. ADDITIONAL BUCKETS AND PANS OF EXCESS OIL WERE OBSERVED THROUGHOUT THE SPACE. 74SOLAS(14 CONS) CH.I/11
Action required: 30 - Ship detained
Due 30 April 2018
Resolved 2 May 2018
Resolution: See Class report.
Engineering › Fuel Oil Service System › Hose
Issued 29 April 2018 Resolved
PSCO'S OBSERVED EXCESSIVE OIL SOAKED LAGGING ON THE MAIN ENGINE FUEL LINE. 74 SOLAS(14 CONS.) CH.I/11
Action required: 30 - Ship detained
Due 30 April 2018
Resolved 2 May 2018
Resolution: See Class report.
Engineering › Steering Gear System › Ram
Issued 29 April 2018 Resolved
STEERING GEAR ROOM WAS FOUND WITH EXCESSIVE HYDRAULIC OIL AND HYDRAULIC OIL DRIPPING OUT OF THE HYDRAULIC RAMS. 74 SOLAS(14 CONS.) CH.I/11
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2018
Resolved 2 May 2018
Resolution: See Class report.
Engineering › Fuel Oil Service System › Filter
Issued 29 April 2018 Resolved
PSCO OBSERVED THE GENERAL FUEL OIL DISCHARGE FILTER WAS OBSERVED WITH A NOTE WHICH READ "PLS DO NOT SWITCH ON!" SOLAS 74(14 CONS.)CH-I/11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2018
Resolution: See Class report.
Engineering › Fuel Oil Service System › Valve, Control
Issued 29 April 2018 Resolved
THE FUEL OIL VISCOMETER CONTROL BOX WAS FOUND SUPPORTED BY A TURN-BUCKLE AND RAG. SOLAS 74(14 CONS.) CH-I/11
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2018
Resolved 2 May 2018
Resolution: See Class report.
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 29 April 2018 Resolved
PSCO OBSERVED THE VESSEL'S CREW NOT TESTING, OPERATING, OR LOGGING THE OWS OPERATIONS AS REQUIRED BY THE COMPANY'S VESSEL SAFETY MANAGMENT SYSTEM. ADDITIONALLY, THE OVERALL SIGNIFICANCE OF THE OWS AND EXCESSIVE OIL FOUND IN THE ENGINE ROOM, AN EXTERNAL SAFETY MANAGEMENT SYSTEM AUDIT IS RECOMMENDED.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2018
Resolved 2 May 2018
Resolution: See Class report.
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 26 May 2016 Resolved
0613 - Each lifeboat shall be provided with an appliance which is capable of launching and recovering the lifeboat. During abandon ship drill, crew lowered port side life boat and is unable to recover the lifeboat to its stoawage position. 74 SOLAS (14 Con. Ed.) Ch. III/16.2 Action: 17a
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2016
Resolution: Received class report attesting to proper repairs (flat bar holding toffle pin for securing the brake handle renewed) and witnessed lifeboat being lowered and recovered to storage location.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.