Records from 1991 to 2025. Most recent: inspection, 16 October 2025.
Inspection history · 55
16 October 2025
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8247188
22 January 2025
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8067694
15 November 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 8034722
17 October 2023
Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7809758
19 September 2023
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7794310
5 September 2023
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7784802
28 August 2023
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7770308
14 November 2022
Annual Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7594269
1 February 2022
Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 7388751
21 September 2021
Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7309299
11 December 2020
Annual Inspection · Drydock Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7109118
7 January 2020
Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6884433
7 January 2020
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6884639
27 December 2019
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6879701
26 November 2019
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6866504
14 November 2019
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6855572
8 October 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6830654
24 August 2018
Administrative Inspection · Initial Certification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6521442
31 October 2017
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6298294
26 September 2017
Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6274875
18 September 2014
Industry Initiated Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4986845
8 June 2014
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4930599
13 June 2012
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4348871
29 June 2011
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4061814
2 June 2011
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4033134
26 May 2011
Industry Initiated Exam · MTSA Verification
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4022936
18 September 2008
Uninspected Other
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3328038
19 December 2006
Uninspected Other · MTSA Verification
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2843048
11 December 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2257407
28 November 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2249043
8 September 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2190414
17 August 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2169341
12 August 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2164479
9 August 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2160989
30 March 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2034225
1 January 2004
Type not recorded
No type recorded · USCGC STEELHEAD (WPB 87324) · USCG East District (CGD-E) · Activity 1974550
8 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1972201
3 June 2002
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1626823
7 July 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 104309
30 June 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 279608
26 June 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 279417
13 May 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 231341
10 May 1999
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 126329
25 April 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 53441
17 December 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 144982
22 October 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 88569
19 November 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 78672
3 October 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 27293
2 February 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 453338
15 July 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 158133
13 June 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 69281
29 April 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 80953
14 April 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 32321
9 January 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 645134
10 December 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 69317
08 - Alarms › N/A - No Subsystem › General alarm
Issued 16 October 2025
Resolved
Each towing vessel must be fitted with a general alarm that...has installed, in the engine room and any other area where background noise makes a general alarm hard to hear, a supplemental flashing red light. Vessel did not have a working red flashing light installed in the engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 October 2025
Resolution: Replaced in kind.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 16 October 2025
Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated. Port main diesel engines was found with a missing section of exhaust lagging where engine room meets main deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 October 2025
Resolution: Replaced worn area.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 October 2025
Resolved
Employers must maintain records IAW 49 CFR 40.333; records shall ID the total number of individuals chemically tested annually for dangerous drugs. Current list of crew members enrolled in drug and alcohol program was not available for inspection. Provide current list.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 October 2025
Resolution: Provided list.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 March 2025
Resolved
An approved 160-B semi-portable fire-extinguishing system to protect the engine room must be equipped. No 160-B fire extinguisher was located in the engine room. O/O to permanently install a 160-B fire extinguisher in or near engine room.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 8 April 2025
Resolved 8 April 2025
Resolution: Required extinguisher installed.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 25 March 2025
Resolved
Each towing vessel must have the following alarms provided: aux gen engine low lube oil pressure, aux gen engine high cool water temp. Crew was unable to test newly installed gen alarms. O/O to ensure new generator alarms are operable and tested to the satisfaction of a CGMI.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 8 April 2025
Resolved 8 April 2025
Resolution: Alarms proven operable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 January 2025
Resolved
Nonmetallic flexible hose complying with SAE J1942 is acceptable fuel piping. New gens did not have approved hoses installed. O/O to install approved fuel hoses.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 8 April 2025
Resolved 8 April 2025
Resolution: Proper hoses installed.
09 - Working and Living Conditions › 091 - Living Conditions › No direct openings into sleeping rooms cargo/mach.
Issued 22 January 2025
Resolved
Machinery and fuel tank spaces must be separated from accommodation spaces by bulkheads. Overhead in engine room is wasted and open into accom space. Crop and renew wasted overhead in engine room.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 April 2025
Resolved 8 April 2025
Resolution: Overhead renewed with good metal.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 January 2025
Resolved
Verification of compliance with the construction and arrangement design standards of this part must be performed on a vessel on which a new installation that is not a "replacement in kind" before the new installation is performed. New generators, not "replacement in kind," were installed on the vessel without verification of compliance with design standards. O/O to provide plan approval for gen swap and CGMI to inspect to satisfaction prior to movement.
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Due 24 April 2025
Resolved 22 April 2025
Resolution: Received generator exhaust drawing, exhaust muffler spec sheet, and letter from generator manufacturer attesting that the existing 4" mufflers are permissible for the new generator installation. Received generator wiring drawing and wiring spec sheet from
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 28 August 2023
Resolved
Each person in charge of the navigation or maneuvering of a towing vessel of at least 8 meters (26 feet) in
length must satisfy the requirements of §15.805(a)(5) of this part or hold a license or MMC authorizing service as either— (1) Mate (pilot) of towing vessels. The mate onboard has an expired license and expired medical certificate. Provide objective evidence of a properly credentialed mate, to meet the manning levels of the COI or provide objective evidence that the vessel's operations will be no more than 12 hours in every 24 hour period and within 14 days request the minimum safe manning level on the COI be reduced by one mate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2023
Resolved 29 August 2023
Resolution: Mate was replaced with a properly credentialed mariner
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 August 2023
Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. The first aid kit located on the bridge had items that expired in 2002 and 2005 and the first aid kit in galley/mess deck had numerous items missing. Provide objective evidence that an appropriate first aid kit is onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 September 2023
Resolved 29 August 2023
Resolution: Objective evidence of an acceptable first aid kit was received.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 28 August 2023
Resolved
Any piping system that penetrates the hull below the waterline must be fitted with an accessible valve, located as close to the hull penetration as is practicable, for preventing the accidental admission of water into the vessel either through such pipes or in the event of a fracture of such pipe. The valve must be clearly marked by labeling or color coding that enables the crew to identify its function. Grey water overboard piping located on port side forward outboard of sewage tank is deteriorated with synthoglass wrapping from hull extending inward 2 feet. Also has flexible hose attached to a "T" fitting with an expandable plug. Replace grey water. Renew piping section with acceptable labeled overboard valve and remove hose section and plug piping.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2023
Resolved 5 September 2023
Resolution: Received objective evidence that pipe was removed and properly plugged.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 28 August 2023
Resolved
Any piping system that penetrates the hull below the waterline must be fitted with an accessible valve,located as close to the hull penetration as is practicable, for preventing the accidental admission of water into the vessel either through such pipes or in the event of a fracture of such pipe. The valve must be clearly marked by labeling or color coding that enables the crew to identify its function. Vessel has a 1 inch pipe with valve going nowhere located on port side E/R bulkhead near overhead aft of grey water overboard piping. Remove valve and pipe section and plug sideshell penetration.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2023
Resolved 29 August 2023
Resolution: Received objective evidence that a servicable valve/handle was placed on dead ended pipe.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 August 2023
Resolved
There must be an installed or portable bilge pump for emergency dewatering. Any portable pump must have sufficient hose length and pumping capability. All installed bilge piping must have a check/foot valve in each bilge suction that prevents unintended backflooding through bilge piping. Engine room bilge suction is clogged and missing check/foot valve. Prove proper operation of installed E/R bilge piping.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2023
Resolved 29 August 2023
Resolution: Received objective evidence of bilge pump working properly.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 28 August 2023
Resolved
All seals and gaskets must be properly maintained to prevent leaks of flammable or combustible liquid, as those terms are defined in 46 CFR subpart 30.10, into the machinery space. Port and Starboard fuel valves located in forward bulkhead of engine room in front of stbd generator and MSD are leaking fuel from valve stems. Repair/renew valves.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2023
Resolved 29 August 2023
Resolution: Valves were tightened down and leak stopped.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 August 2023
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Port engine starting battery positive terminal is badly corroded and 1 wire is showing through insulation. Clean and re-install battery connections.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2023
Resolved 5 September 2023
Resolution: Received objective evidence that the battery was replaced
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 August 2023
Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. Overhead wiring in engine room is supported by plastic zip-ties only. Remove all plastic zip-ties and renew with metal ties or strapping.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2023
Resolved 19 September 2023
Resolution: Metal bands were installed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 August 2023
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. #20 breaker in 120 volt breaker panel is tripped and inoperable. Remove/renew breaker.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2023
Resolved 29 August 2023
Resolution: Breaker was removed and blank put in its place
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 28 August 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Potable water pipe penetrating forward bulkhead starboard in front of stbd generator has rubber pipe patch installed. Renew piping section from joint to union.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2023
Resolved 29 August 2023
Resolution: Permanent repairs were made.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 28 August 2023
Resolved
The owner or managing operator of a vessel equipped with an EPIRB must maintain valid proof of registration. The registration form was available but did not indicated the vessel's call sign nor MMSI and the registration letter and decal was not available for inspection. In addition, the decal on the existing EPIRB was expired. Provide objective evidence of EPIRB registration.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 August 2023
Resolved 4 October 2023
Resolution: EPRIB was properly registered
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 1 December 2022
Resolved
[name withheld] vessel had in excess of 3" of oily water in the bilge.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 1 December 2022
Resolved 1 December 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 December 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2022
Resolved 6 December 2022
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 December 2022
Resolved
MI notice vessel's stern light was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2022
Resolved 7 December 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 December 2022
Resolved
MI found that the port side life ring was dry rotted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2022
Resolved 6 December 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 December 2022
Resolved
MI found multiple lifejackets were missing lifejacket lights.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2022
Resolved 7 December 2022
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 December 2022
Resolved
MI found that the hydrostatic release on EPIRB was past expiration date.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2022
Resolved 6 December 2022
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 December 2022
Resolved
Vessel could not provide valid proof of registration for the EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2022
Resolved 7 December 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 1 December 2022
Resolved
Vessel did not have RPM and cooling water gauging for the mains and did not have RPM gauging for auxiliary generator engine locally.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 December 2022
Resolved 7 December 2022
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 14 November 2022
Resolved
MI discovered all berthing areas had no form of emergency lighting.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2022
Resolved 12 December 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 January 2020
Resolved
Vessel was hauled out at Blakley Boatworks to make repairs to the starboard shaft seal. The seal failed and was allowing water intrusion into the stuffing box, in the engine room. Repairs shall be made and inspected to the satisfaction of the attending Coast Guard Marine Inspector, prior to going back into operation.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 January 2020
Resolved 8 January 2020
Resolution: Deficiency Cleared By [name withheld]
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 November 2019
Resolved
Fire pump was found inop. Prove proper operation of fire pump.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 November 2019
Resolved 26 November 2019
Resolution: Vsl obtained a portable pump until the fixed pump could be repaired. Allowed vsl to sail and to rectify def within 14 days.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 November 2019
Resolved
Provide waterproof container for distress flares.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2019
Resolved 26 November 2019
Resolution: Container for distress signals was provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 November 2019
Resolved
Provide approved brackets for 5 portable fire extingushers .
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2019
Resolved 26 November 2019
Resolution: 5 approved brackets were provided for portable fire extingushers.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 November 2019
Resolved
Provide missing smoke detectors in berthing areas.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 27 November 2019
Resolved 13 November 2019
Resolution: Provided missing smoke detectors.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 13 November 2019
Resolved
Replace cracked hydraulic lines for steering gear.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 November 2019
Resolved 26 November 2019
Resolution: Cracked hydraulic hoses were replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 November 2019
Resolved
Clear debris from engineroom bilge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2019
Resolved 26 November 2019
Resolution: Debris in eng rm bilge was removed.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 13 November 2019
Resolved
Prove proper operation of Port Gen Low Oil Level alarm.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2019
Resolved 26 November 2019
Resolution: Low oil level alarm for port gen was adjusted and operational.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 13 November 2019
Resolved
Provide covers (2) for lights in fwd hold.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2019
Resolved 26 November 2019
Resolution: Missing light covers in fwd hold were replaced.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 November 2019
Resolved
Prove proper operation of stbd sea chest valve for fire pump.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2019
Resolved 26 November 2019
Resolution: STBD sea chest valve was replaced. Tested sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 November 2019
Resolved
Clear items stored in front of B-160 fire extingusher.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 November 2019
Resolved 13 November 2019
Resolution: Items blocking route to fire extingusher were moved.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 November 2019
Resolved
Provide fire detection servicing record.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2019
Resolved 26 November 2019
Resolution: Fire detection panel was serviced and operational.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 13 November 2019
Resolved
Engine roomm fire alarm strobe was inoperable. Prove proper operation of eng room fire alarm strobe.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2019
Resolved 26 November 2019
Resolution: Fire alarm strobe was replaced. Tech report was provided.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 November 2019
Resolved
Provide stern light - white.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2019
Resolved 2 December 2019
Resolution: Stern light mounted aft of Texas deck. Deficiency cleared.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 13 November 2019
Resolved
Provide VHF radios with MMSI numbers.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 27 November 2019
Resolved 13 November 2019
Resolution: MMSI was installed into VHF radios.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 13 November 2019
Resolved
Provide updated charts for area of operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2019
Resolved 27 December 2019
Resolution: Vessel provided updated charts to MSU Morgan City.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 November 2019
Resolved
Secure exhaust lagging for both gens.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2019
Resolved 26 November 2019
Resolution: Exhaust lagging on both gens was properly secured to reduce risk of burns.
Documentation › Markings/Placards › Vessel Number (state)
Issued 18 September 2008
Resolved
The name of the vessel needs to be marked on the sides port and starboard side of the hull.
Action required: 705 - Other - as specified
Due 20 September 2008
Resolved 26 May 2011
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 18 September 2008
Resolved
Life rings need be orange and the vessel name must be marked on the life ring.
Due 20 September 2008
Resolved 26 May 2011
Fire Fighting › Fire Hoses › Location
Issued 18 September 2008
Resolved
Fire hose needs to be place back at the fire station.
Due 20 September 2008
Resolved 26 May 2011
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 18 September 2008
Resolved
The fire extinguser in the engine room needs to be replaced.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 September 2008
Resolved 26 May 2011
Fire Fighting › Remote Fuel Shutoff › General
Issued 18 September 2008
Resolved
Vessel needs a mechanical fuel shutoff system.
Action required: 705 - Other - as specified
Due 1 October 2008
Resolved 26 May 2011
Fire Fighting › Remote Fuel Shutoff › General
Issued 19 December 2006
Resolved
46 CFR 27. 207 Failure to comply with the requirements for fuel shut-offs on a towing vessel. SHUT OFF SHOULD BE MECHANICALLY ACTUATED NOT HYDRAULICALLY ACTUATED
Action required: 705 - Other - as specified
Due 19 February 2007
Resolved 26 May 2011
Construction/Loadline
Issued 26 June 2000
Resolved
Name and hailing port on stern was not painted in contrasting color.
Condition: Unknown
Due 30 June 2000
Resolved 5 July 2000
Construction/Loadline
Issued 26 June 2000
Resolved
Official number not permanently affixe on interior hull.
Condition: Unknown
Due 30 June 2000
Resolved 5 July 2000