Records from 2009 to 2025. Most recent: inspection, 20 October 2025.
Documentation record
Registered dimensions (L × B × D)348.0 ft × 62.0 ft × 24.5 ft
Registered tonnagegross 4,238 / net 2,521
ITC dimensions (L × B × D)348.0 ft × 62.0 ft × 24.5 ft
ITC tonnagegross 4,238 / net 2,521
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2010
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBALTIMORE, MD
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 14 November 2025 · expires 31 October 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it4238 - Convention (Subpart B), Gross Ton
2521 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 28
20 October 2025
Cargo Tank Internal · Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8255405
19 July 2025
Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8189354
18 June 2025
Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8162120
4 December 2024
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8043005
13 September 2023
Periodic Inspection · MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7791126
9 June 2023
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7713553
28 January 2023
In-Service Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7628403
13 December 2022
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7608313
5 December 2022
Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7603381
16 July 2022
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7512082
2 December 2021
MTSA Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7360851
13 October 2020
MARPOL Annex I Examination · MARPOL Annex VI Survey · COI Inspection · MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7073090
21 August 2020
Internal Structural Exam · Drydock Exam · Cargo Tank Internal
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7073839
6 April 2020
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6943049
15 July 2019
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6750866
11 June 2019
Bulk Liquid Transfer Monitor
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6712647
26 March 2018
MTSA Verification · Periodic Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6378761
18 May 2017
Annual Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6148935
25 April 2016
MTSA Verification · MARPOL Annex I Examination · MARPOL Annex VI Survey · MARPOL Annex II Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5862295
26 August 2015
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5226661
20 May 2015
COI Inspection · SIP Inspection/Audit · MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5130487
23 April 2015
Internal Structural Exam · Cargo Tank Internal · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5109293
27 May 2014
DAPI Audit · SIP Inspection/Audit
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4873137
15 November 2013
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4753197
17 April 2012
MARPOL Annex I Examination · MTSA Verification · MARPOL Annex VI Survey · SIP Inspection/Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4288912
19 July 2011
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4087368
16 August 2010
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3826838
17 July 2009
Cargo Tank Internal · Internal Structural Exam · Construction Oversight · Initial Certification · MTSA Verification · Hull Examination
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3675875
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 5 December 2022
Resolved
Each cargo tank of a tankship must be equipped with an intrinsically safe high-level alarm and a tank overfill alarm ... [and] ... must be independent of each other. PCT#5 Hi/Hi-Hi (overfill) alarm sounds whenever another tank's Hi/Hi-Hi alarm is activated regardless of the condition of PCT#5. Repair PCT#5 High level Alarm so that it alerts only in response to an High level condition in PCT#5.
CITE: 46 CFR §39.2007
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2023
Resolved 13 December 2022
Resolution: Resolved via video & telecon w/ vsl rep
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 July 2022
Resolved
Barges certified as tank barges (Subchapter D of this chapter) or cargo barges (Subchapter I of this chapter) for the carriage of cargoes regulated by this subchapter shall meet all applicable requirements for operations in the appropriate subchapters; in addition, requirements prescribed in this subpart shall apply to either type of certification.
Vsl reported touching bottom while moored at Windy Point Pier, NJ during active onload of ethanol. Upon discovery of soft grounding, vsl seized all cargo operations. Vsl reported no apparent damage or pollution on board or in the surrounding water.
Vsl shall conduct and underwater dive survey of the hull prior to cargo operations and provide supporting documentation.
Prior to departure, vsl is authorized local movement from Windy Point Pier to City Pier, Philadelphia, PA.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2022
Resolution: Vsl conducted satisfactory underwater survey of the hull; no damage reported. Reviewed provided dive survey report, grounding survey, & ABS class report; vsl deemed in satisfactory condition. Deficiency cleared.
Construction/Loadline › Hull › Side Shell
Issued 26 March 2018
Resolved
Issued 01 deficiency, 00 deficiencies cleared, 01 remain outstanding. Inspection ongoing for ISE deficiency repairs.
Action required: 705 - Other - as specified
Due 30 April 2018
Resolved 9 April 2018
Resolution: Verified all welds in person, all sat.