Records from 2009 to 2020. Most recent: inspection, 26 March 2020.
Inspection history · 18
26 March 2020
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6931783
1 April 2019
Type not recorded
No type recorded · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6656514
21 February 2019
Damage Survey
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6630646
31 May 2018
COI Inspection · Damage Survey · Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6430763
14 June 2017
Type not recorded
No type recorded · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6175845
17 May 2017
Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6148755
17 March 2017
Damage Survey · Hull Examination · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6106433
24 February 2016
Type not recorded
No type recorded · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5820988
26 January 2016
Deficiency Check · COI Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5803354
29 December 2015
Deficiency Check · Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5803352
11 December 2015
Damage Survey
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5779698
5 June 2012
Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4337352
26 July 2011
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4094781
13 July 2011
Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4085811
1 July 2011
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4090372
9 January 2010
Type not recorded
No type recorded · USCGC PEA ISLAND (WPB 1347) - Port · USCG Southeast District (CGD-SE) · Activity 3670692
14 December 2009
Simplified Stability Test
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3651957
17 July 2009
Drydock Exam · Administrative Inspection · Deficiency Check · Initial Certification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3812954
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 February 2019
No resolution recorded
Port gunwale sustained damaged (cracks) when vessel struck steel pilings. Repair was observed to be in progress.
Also, MI observed cracks in transom rail and Port gunwale.
Action required: 17 - Rectify deficiencies prior to departure
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 February 2019
No resolution recorded
Starboard engine oil pump reported faulty.
Action required: 17 - Rectify deficiencies prior to departure
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 February 2019
No resolution recorded
Propellers were reported damaged (removed from vessel).
Action required: 17 - Rectify deficiencies prior to departure
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 1 August 2018
No resolution recorded
Vessel FCC radio station license unavailable.
Action required: 705 - Other - as specified
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Health protection, medical care?)
Issued 1 August 2018
Resolved
No Drug and Alcohol policy avaiable.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 January 2019
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 26 January 2016
Resolved
Prove a man overboard (MOB) drill to the satisfaction of the attending Marine Inspector
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 February 2016
Resolution: The crew was able to satisfactorily demonstrate a man over board drill
Electrical › Electrical Distribution System (service) › Cable
Issued 23 December 2009
Resolved
Cables for power and lighting must meet the construction requirements in 46 CFR 183.340(d). Provide cable type and construction details.
Action required: 705 - Other - as specified
Resolved 1 June 2010
Electrical › Electrical Distribution System (service) › Conductor
Issued 23 December 2009
Resolved
The conductor for the generator is 6/3, which is rated for 65 amps. The generator produces 75 amps according. Verify that the conductor is sized appropriately for the generator, see 46 CFR 183.340(o).
Action required: 705 - Other - as specified
Resolved 1 June 2010
Electrical › Electrical Distribution System (service) › Conductor
Issued 23 December 2009
Resolved
The ground connection must be at the switchboard or at a common ground plate. This connection must be accessible for checking insulation resistance to ground, see 46 CFR 183.376. If ungrounded, then double pole breakers must be installed instead of single pole breakers as per electrical diagram and a ground detection system most be installed.
Action required: 705 - Other - as specified
Resolved 1 June 2010
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 23 December 2009
Resolved
Provide revision as requested per MSC Letter E1-0903541 regarding schematics revisions needed from enclosures 6 to 19.
Action required: 705 - Other - as specified
Resolved 3 March 2010
Communications › Radio Communications › EPIRB
Issued 23 December 2009
Resolved
The EPIRB is located inside the wheel house. Relocate EPIRB outside wheel house in a float free arrangement.
Action required: 705 - Other - as specified
Resolved 27 January 2010
Lifesaving › Lifefloat › Float-free Link
Issued 23 December 2009
Resolved
Installed weak link rated for life float onboard vessel.
Action required: 705 - Other - as specified
Resolved 3 March 2010
Engineering › Bilge Water Management System › Pump
Issued 23 December 2009
Resolved
Suction hose was not long enough to pump out water of the vessel from the bilges.
Action required: 705 - Other - as specified
Resolved 27 January 2010
Lifesaving › Hand Flares › Storage
Issued 23 December 2009
Resolved
Distress signals required to be stored in a watertight brigth container with the marking "Distress Signals" stenciled.
Action required: 705 - Other - as specified
Resolved 27 January 2010
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 December 2009
Resolved
Provide CG approved First Aid Kit.
Action required: 705 - Other - as specified
Resolved 27 January 2010