Records from 2016 to 2025. Most recent: inspection, 5 May 2025.
Documentation record
Registered dimensions (L × B × D)38.4 ft × 13.4 ft × 6.2 ft
Registered tonnagegross 17 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEWINGTON, NH, UNITED STATES
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCABO ROJO, PR
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 17 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it17 - Regulatory (Subpart C or D), Gross Ton
14 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 16
5 May 2025
Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8129036
24 February 2025
Drydock Exam · Examination of Repairs · Administrative Inspection · Internal Structural Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8087197
19 December 2024
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8049392
16 August 2023
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7769783
6 June 2022
Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7467320
22 March 2022
Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7416579
16 November 2021
Internal Structural Exam · Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7352058
19 February 2020
In-Service Inspection · Annual Inspection · Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6911702
20 August 2019
Drydock Exam · Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6845663
11 February 2019
COI Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6618725
8 January 2019
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6609402
31 May 2018
Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6430739
8 August 2017
Damage Survey · Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6236245
2 August 2017
Damage Survey
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6228045
9 January 2017
Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6067945
24 February 2016
Type not recorded
No type recorded · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5820988
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 7 October 2022
No resolution recorded
Any vessel of at least five net tons which engages in the fisheries on the navigable waters of the United States or in the Exclusive Economic Zone, or coastwise trade, unless exempt under § 67.9(c), must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. Provide a valid COD.
Action required: 17 - Rectify deficiencies prior to departure
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 June 2022
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. Required 10-B: C fire extinguisher found to be with no charge. Replace fire extinguisher. 46CFR181.500 (a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 October 2022
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 6 June 2022
Resolved
Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, Record of EPIRB testing missing. 46CFR185.728
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 October 2022
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 6 June 2022
Resolved
The master shall conduct sufficient drills, MOB, abandon ship and Firefighting drill record missing. Perform and log required logs. 46CFR185.520 (a) , 46CFR185.524
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 October 2022
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 22 March 2022
Resolved
Stow and equip survival floats IAW , 46CFR180.130, 46CFR180.137, 180.175.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2022
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 16 November 2021
Resolved
Steering space, STBD quarter corner of stringer, remove foam cap and sand down to good material and re-glass. Submit repair proposal.
Action required: 705 - Other - as specified
Resolved 30 November 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 19 February 2020
Resolved
Watertight hatch cover latch in forward cabin deck missing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2020
Resolution: Marine Inspector verified hatch repair.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 19 February 2020
Resolved
Crew was unable to demonstrate use of installed SSB / MF radio. Radio was observed tuned to 2182 Khz, an obsolete frequency.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2020
Resolution: FCC tech report received. Tech provided training to vessel crew of the proper use of the SSB radio.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 19 February 2020
Resolved
Captain did not possess an FCC Marine Radio Operators Permit.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2020
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 19 February 2020
Resolved
Evidence of crew training required by 46 CFR 185.420 was not available to Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 March 2020
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 19 February 2020
Resolved
Provide at least 1 three foot floatable lanyard for the installed life buoy light.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 March 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 February 2020
Resolved
Emergency Instructions required by 46 CFR 185.510 not onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 March 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 February 2020
Resolved
Six adult lifejackets wasted.
Action required: 10 - Deficiency Rectified
Resolved 3 March 2020
Resolution: Vessel owner provided six new repalcement Type I life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 19 February 2020
Resolved
Retro relective tape on life bouy wasted.
Action required: 10 - Deficiency Rectified
Resolved 3 March 2020
Resolution: Vessel Owner provided and applied approved retro reflective tape to ring buoy.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 19 February 2020
Resolved
Charts and publications not provided onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 March 2020
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 9 January 2017
Resolved
Replace all fuel lines with approved Type as per 46 CFR 182.700(e)3
Action required: 705 - Other - as specified
Due 23 January 2017
Resolved 23 January 2017
Resolution: Replaced all fuel lines with approved Type as per 46 CFR 182.700(e)3
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 9 January 2017
Resolved
Install the two missing flame bowls on both Racor brand fuel filters.
Action required: 705 - Other - as specified
Due 23 January 2017
Resolved 23 January 2017
Resolution: Installed the two missing flame bowls on both Racor brand fuel filters.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 9 January 2017
Resolved
Install missing clamp on port MDE exhaust located first void aft of engine room.
Action required: 705 - Other - as specified
Due 23 January 2017
Resolved 23 January 2017
Resolution: Installed the missing clamp on port MDE exhaust located first void aft of engine room.
Documentation › Markings/Placards › Lifejacket Placard
Issued 9 January 2017
Resolved
Install missing Life Jacket Donning Placard
Action required: 705 - Other - as specified
Due 23 January 2017
Resolved 23 January 2017
Resolution: Installed the missing Life Jacket Donning Placard
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 9 January 2017
Resolved
Replace expired life-ring float light battery
Action required: 705 - Other - as specified
Due 23 January 2017
Resolved 23 January 2017
Resolution: Replaced the expired life-ring float light battery