Records from 2001 to 2025. Most recent: inspection, 5 May 2025.
Inspection history · 38
5 May 2025
Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8129036
24 February 2025
Drydock Exam · Examination of Repairs · Administrative Inspection · Internal Structural Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8087197
19 December 2024
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8049392
16 August 2023
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7769783
6 June 2022
Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7467320
22 March 2022
Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7416579
16 November 2021
Internal Structural Exam · Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7352058
19 February 2020
In-Service Inspection · Annual Inspection · Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6911702
20 August 2019
Drydock Exam · Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6845663
11 February 2019
COI Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6618725
8 January 2019
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6609402
31 May 2018
Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6430739
8 August 2017
Damage Survey · Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6236245
2 August 2017
Damage Survey
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6228045
9 January 2017
Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6067945
24 February 2016
Type not recorded
No type recorded · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5820988
17 December 2015
Hull Examination · Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5783897
13 January 2012
Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4224159
16 December 2010
Hull Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 3913620
30 March 2010
Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3705551
19 December 2008
Hull Examination · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3382567
18 December 2008
Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3521496
15 February 2008
COI Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3147488
7 April 2007
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2905670
23 February 2007
Type not recorded
No type recorded · USCGC SAPELO (WPB 1314) · USCG Southeast District (CGD-SE) · Activity 2882837
5 May 2006
Type not recorded
No type recorded · USCGC OCRACOKE (WPB 1307) · USCG Southeast District (CGD-SE) · Activity 2694878
6 July 2005
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2416694
1 June 2005
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2383472
9 February 2005
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2292290
7 December 2004
Hull Examination · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2259168
6 April 2004
Deficiency Check · Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2039050
14 January 2004
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1985068
16 December 2003
Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1985173
25 February 2003
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1750685
8 January 2003
Initial Certification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1731401
2 January 2003
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1728091
10 December 2002
Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1717476
1 May 2001
Uninspected Other
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1063323
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 7 October 2022
No resolution recorded
Any vessel of at least five net tons which engages in the fisheries on the navigable waters of the United States or in the Exclusive Economic Zone, or coastwise trade, unless exempt under § 67.9(c), must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. Provide a valid COD.
Action required: 17 - Rectify deficiencies prior to departure
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 June 2022
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. Required 10-B: C fire extinguisher found to be with no charge. Replace fire extinguisher. 46CFR181.500 (a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 October 2022
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 6 June 2022
Resolved
Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, Record of EPIRB testing missing. 46CFR185.728
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 October 2022
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 6 June 2022
Resolved
The master shall conduct sufficient drills, MOB, abandon ship and Firefighting drill record missing. Perform and log required logs. 46CFR185.520 (a) , 46CFR185.524
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 October 2022
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 22 March 2022
Resolved
Stow and equip survival floats IAW , 46CFR180.130, 46CFR180.137, 180.175.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2022
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 16 November 2021
Resolved
Steering space, STBD quarter corner of stringer, remove foam cap and sand down to good material and re-glass. Submit repair proposal.
Action required: 705 - Other - as specified
Resolved 30 November 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 19 February 2020
Resolved
Watertight hatch cover latch in forward cabin deck missing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2020
Resolution: Marine Inspector verified hatch repair.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 19 February 2020
Resolved
Crew was unable to demonstrate use of installed SSB / MF radio. Radio was observed tuned to 2182 Khz, an obsolete frequency.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2020
Resolution: FCC tech report received. Tech provided training to vessel crew of the proper use of the SSB radio.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 19 February 2020
Resolved
Captain did not possess an FCC Marine Radio Operators Permit.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2020
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 19 February 2020
Resolved
Evidence of crew training required by 46 CFR 185.420 was not available to Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 March 2020
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 19 February 2020
Resolved
Provide at least 1 three foot floatable lanyard for the installed life buoy light.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 March 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 February 2020
Resolved
Emergency Instructions required by 46 CFR 185.510 not onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 March 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 February 2020
Resolved
Six adult lifejackets wasted.
Action required: 10 - Deficiency Rectified
Resolved 3 March 2020
Resolution: Vessel owner provided six new repalcement Type I life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 19 February 2020
Resolved
Retro relective tape on life bouy wasted.
Action required: 10 - Deficiency Rectified
Resolved 3 March 2020
Resolution: Vessel Owner provided and applied approved retro reflective tape to ring buoy.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 19 February 2020
Resolved
Charts and publications not provided onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 March 2020
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 9 January 2017
Resolved
Replace all fuel lines with approved Type as per 46 CFR 182.700(e)3
Action required: 705 - Other - as specified
Due 23 January 2017
Resolved 23 January 2017
Resolution: Replaced all fuel lines with approved Type as per 46 CFR 182.700(e)3
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 9 January 2017
Resolved
Install the two missing flame bowls on both Racor brand fuel filters.
Action required: 705 - Other - as specified
Due 23 January 2017
Resolved 23 January 2017
Resolution: Installed the two missing flame bowls on both Racor brand fuel filters.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 9 January 2017
Resolved
Install missing clamp on port MDE exhaust located first void aft of engine room.
Action required: 705 - Other - as specified
Due 23 January 2017
Resolved 23 January 2017
Resolution: Installed the missing clamp on port MDE exhaust located first void aft of engine room.
Documentation › Markings/Placards › Lifejacket Placard
Issued 9 January 2017
Resolved
Install missing Life Jacket Donning Placard
Action required: 705 - Other - as specified
Due 23 January 2017
Resolved 23 January 2017
Resolution: Installed the missing Life Jacket Donning Placard
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 9 January 2017
Resolved
Replace expired life-ring float light battery
Action required: 705 - Other - as specified
Due 23 January 2017
Resolved 23 January 2017
Resolution: Replaced the expired life-ring float light battery
Lifesaving › Lifefloat › Serviceable
Issued 30 March 2010
Resolved
two of three lifefloats need to be conditiones, oars need name stenciled, missing one light. correct prior to taking on passengers.
Action required: 705 - Other - as specified
Due 30 March 2010
Resolved 28 April 2010
Resolution: Lifefloats have been conditioned, oars have name stenciled, light put on board.
Communications › Radio Communications › EPIRB
Issued 30 March 2010
Resolved
Battery for the EPIRB is expired, replace prior to taking on passengers
Action required: 705 - Other - as specified
Due 30 March 2010
Resolved 28 April 2010
Resolution: New battery installed
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 30 March 2010
Resolved
missing navigation rules book, purchase and place on board prior to getting underway
Action required: 705 - Other - as specified
Due 7 April 2010
Resolved 28 April 2010
Resolution: Navigational Rules of the Road book is on board
Engineering › Fuel Oil Service System › Valve
Issued 15 February 2008
Resolved
Provide a positive shut-off valves for fuel suction lines as close to main engines as positive.
Condition: Improper Installation
Due 1 March 2008
Resolved 4 March 2008
Resolution: Valve installed. /JAR
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 15 February 2008
Resolved
Install horizontal rail courses evenly spaced so that there is no more than 12-inches of open space aft port and starboard sides of main deck. May install canvas material (or other similar material) like rest of railing.
Condition: Improper Installation
Due 1 March 2008
Resolved 4 March 2008
Resolution: Canvas re-installed. /JAR
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 15 February 2008
Resolved
Replace retroflective tape on all lifefloats and ring buoy using Coast Guard approved retroflective material.
Condition: Design Flaw
Due 15 March 2008
Resolved 4 March 2008
Resolution: Tape replaced./ JAR
Fire Fighting › Fire Bucket › Quantity
Issued 15 February 2008
Resolved
Provide onboard three 2.5gls fire buckets stenciled 'Fire Buckets" with approx. 6-foot lanyard on each bucket.
Condition: Improper/Lack of Maintenance
Due 15 March 2008
Resolved 4 March 2008
Resolution: Buckets provided with landyard./ JAR
Operations/Management › Drills/Instruction › Safety Orientation
Issued 15 February 2008
Resolved
Provide onboard vessel specific emergency instructions (Note: may use the guide provided by U.S. Coast Guard).
Due 15 March 2008
Resolved 4 March 2008
Resolution: Provided.
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 15 February 2008
Resolved
Provide onboard alcohol breath-testing kit for two crewmembers (i.e. M-PAC kits).
04Mar09- Extended. Owner ordered them, but still wating for them from the consortium. /JAR
Due 31 March 2008
Resolved 11 March 2008
Resolution: Received evidence from owner attesting that new kits received to exp 01/2009.//JAR
Engineering › Bilge Water Management System › Interface Detector
Issued 15 February 2008
Resolved
Install bilge high level alarm, audible and visual indicators, to indicate hi bilge level in each compartment.
Condition: Improper Installation
Due 15 March 2008
Resolved 4 March 2008
Resolution: Individual alarms provided. /JAR
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 February 2008
Resolved
Provide onboard complete Coat Guard approved first aid kit or equivalent.
Condition: Improper/Lack of Maintenance
Due 15 March 2008
Resolved 4 March 2008
Resolution: New equivalent kit provided/ JAR
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 15 February 2008
Resolved
Properly store lifejackets. Ensure child jackets are separated from adults. label storage spaces (adult, child).
Condition: Improper Installation
Due 1 March 2008
Resolved 4 March 2008
Resolution: Racks provided and child jackets stored in bin aft of pilot station. /JAR
Documentation › Certificates/Documents › FCC SSL
Issued 7 April 2007
Resolved
Provide updated FCC Safety Certificate (due to call sign change).
Due 7 May 2007
Resolved 7 April 2007
Resolution: Received e-mail copy from FCC Inspector attesting to issuing a new certificate.
Documentation › Logs/Records › Logbook (official)
Issued 7 April 2007
Resolved
Provide bridge log to log drills and lifesaving equipment inspections.
Due 7 May 2007
Resolved 15 February 2008
Resolution: Provided.
Lifesaving › Buoyant Apparatus › Float Free
Issued 7 April 2007
Resolved
Provide bracket or similar arrangement to 14-person lifefloat to keep lifefloat from sliding on rooftop, but also must be float-free.
Condition: Improper Installation
Due 7 May 2007
Resolved 15 February 2008
Resolution: Corrected.
Electrical › Electric Supply System (service) › Cable
Issued 7 April 2007
Resolved
Make repairs to ground cable in steering room. Both ends of connection at fastener are frayed.
Condition: Design Flaw
Due 7 May 2007
Resolved 15 February 2008
Resolution: Connection repaired.
Lifesaving › Buoyant Apparatus › Quantity
Issued 9 February 2005
Resolved
Provide an additional CG approved lifefloat, stenciled with vessel name, reflective tape and required equipment (sea painter, 2 paddles with vessel name, water-light and weak-link) to accomodate 100% of total number of persons permitted on board as per COI. Provide spacers between life-floats (if stored in tiers as 46CFR180.200(b)(2). Vsl restricted to 20 persons.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 6 July 2005
Resolution: Owner provided an additional 12 person lifefloat.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 December 2004
Resolved
COI is laminated and unable to be endorsed. Provide a written request to the cognizant OCMI for a duplicate COI.
Due 14 January 2005
Resolved 18 January 2005
Lifesaving › Hand Flares › Expired
Issued 13 December 2004
Resolved
Noted two red hand flares that expired in 1999 were in the distress signal box.
Action required: 705 - Other - as specified
Resolved 13 December 2004
Resolution: Master removed the expired flares from the vessel.
Lifesaving › Hand Flares › Quantity
Issued 13 December 2004
Resolved
Vsl missing three orange smoke flares and one hand held red flare.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 December 2004
Resolution: Deck hand layed to the marine hardware store and purchased the missing distress signals.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 13 December 2004
Resolved
Prove the proper operation of the MF single sideband radio prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2004
Communications › Radio Communications › EPIRB
Issued 13 December 2004
Resolved
Prove proper operation of EPIRB in the test mode.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 December 2004
Resolution: Master opened EPIRB and connected electircal cable. Test sat.
Communications › Radio Communications › EPIRB
Issued 13 December 2004
Resolved
Properly mount the EPIRB in a float free arrangement prior to carrying passengers for hire.
Action required: 705 - Other - as specified
Resolved 15 December 2004
Lifesaving › Lifefloat › Float-free Link
Issued 13 December 2004
Resolved
Properly install approved weak lin prior to carrying passengers for hire..
Action required: 705 - Other - as specified
Resolved 13 December 2004
Resolution: Master installed weak link in accordance w/ NVIC 1-83 arrangement note provided by MI.
Lifesaving › Lifefloat › Painter
Issued 13 December 2004
Resolved
Properly attach both painters to the weak link prior to carrying passengers.
Action required: 705 - Other - as specified
Resolved 13 December 2004
Resolution: Both painters attached to one approved weaklink in accordance w/ NVIC 1-83 provided by MI.
Documentation › Markings/Placards › Lifejacket Placard
Issued 13 December 2004
Resolved
Post lifejacket donning placard.
Action required: 705 - Other - as specified
Resolved 13 December 2004
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 13 December 2004
Resolved
Provide and attach buoyant lifeline to ring buoy.
Action required: 705 - Other - as specified
Resolved 13 December 2004
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 13 December 2004
Resolved
Properly mount remaining two portable fire extinguishers.
Action required: 705 - Other - as specified
Resolved 15 December 2004
Engineering › Sea-water System (primary cooling) › Piping
Issued 13 December 2004
Resolved
Double clamp all hoses for both main diesel engines.
Action required: 705 - Other - as specified
Due 13 January 2005
Resolved 18 January 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 6 April 2004
Resolved
Replace the B-I protable fire extinguisher. Extinguisher used during a fire onboard on 01Apr04. LEGACY COMPONENT DESC: Condition
Condition: Placed in Improper Service
Due 6 April 2004
Resolved 6 April 2004
Resolution: Replaced.
Engineering › Bilge Water Management System
Issued 6 April 2004
Resolved
Repair bilge high level alarm. Electrical wiring damaged by fire. LEGACY COMPONENT DESC: High Level Alarms
Condition: Damaged By Earlier Event
Due 25 April 2004
Resolved 27 April 2004
Resolution: Repaired
Electrical › Electrical Distribution System (service)
Issued 6 April 2004
Resolved
Replace all burn electrical wires inside the forward cabin. Wiring was damaged due to a fire onboard on 01Apr04. LEGACY COMPONENT DESC: Wiring
Condition: Damaged By Earlier Event
Due 25 April 2004
Resolved 27 April 2004
Resolution: Wiring replaced.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 6 April 2004
Resolved
Repair the electrical wiring to the propulsion machinery automatic shutdown required as part of the fixed fire fighting system.
Provide a temporary manual mean (pull cables) to shutdown the main engines from the outside the machinery spaces in the event of a fire. LEGACY COMPONENT DESC: Shutdown
Condition: Damaged By Earlier Event
Due 25 April 2004
Resolved 27 April 2004
Resolution: Reapaired and tested sat.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 16 December 2003
Resolved
Replace bow missing safety rail section. LEGACY COMPONENT DESC: Open Deck Space
Condition: Damaged By Earlier Event
Due 14 January 2004
Resolved 14 January 2004
Resolution: Section Replaced.
Lifesaving › Buoyant Apparatus
Issued 16 December 2003
Resolved
Provide spacers for lifefloats.
Condition: Improper Installation
Due 16 January 2004
Resolved 14 January 2004
Resolution: Provided.
Accommodation/Occupational Safety › Medical/First Aid
Issued 16 December 2003
Resolved
Provide a Coast Guard approved first aid kit or equivalent. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Due 16 January 2004
Resolved 14 January 2004
Resolution: Provided.
Engineering › Fuel Oil Storage/Transfer System
Issued 16 December 2003
Resolved
Label purpose of the emergency fuel shut-off valves using a 1 inch letters. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 16 January 2004
Resolved 14 January 2004
Resolution: Vlaves labeled.
Engineering › Fuel Oil Service System
Issued 16 December 2003
Resolved
Provide a metallic fuel collector under each fuel filter. LEGACY COMPONENT DESC: Filter
Condition: Improper Installation
Due 16 January 2004
Resolved 14 January 2004
Resolution: Metal collector provided under both fuel filters.
Navigation › Collision/Grounding Avoidance
Issued 16 December 2003
Resolved
Paint using flat black paint, back of the navigation lights. LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper/Lack of Maintenance
Due 16 January 2004
Resolved 14 January 2004
Resolution: Painted with spray paint.
Navigation › Piloting/Steering
Issued 8 January 2003
Resolved
Provide Coast Pilot or sections of it for the intended voyage. LEGACY COMPONENT DESC: US Coast Pilot
Condition: Unknown
Due 8 February 2003
Resolved 25 February 2003
Resolution: Provided
Communications › Radio Communications
Issued 8 January 2003
Resolved
Provide emergency broadcast placard. LEGACY COMPONENT DESC: VFH Radiotelephone
Condition: Unknown
Due 8 February 2003
Resolved 25 February 2003
Resolution: Provided.
Fire Fighting › Miscellaneous Items
Issued 8 January 2003
Resolved
Repair or replace diesel tank vent mesh screen (30x30) LEGACY COMPONENT DESC: Materials for Overboard Outlets
Condition: Design Flaw
Due 8 February 2003
Resolved 25 February 2003
Resolution: Repaired.
Fire Fighting › Miscellaneous Items
Issued 8 January 2003
Resolved
Provide "NO SMOKING" signs close to diesel tanks.
Condition: Unknown
Due 8 February 2003
Resolved 25 February 2003
Resolution: Signs provided.
Fire Fighting › Combustible Materials
Issued 8 January 2003
Resolved
Label purpose (emergency shut-off valve) and direction of operation of valves.
Condition: Improper/Lack of Maintenance
Due 8 February 2003
Resolved 25 February 2003
Resolution: Done
Lifesaving › Lifebuoys
Issued 8 January 2003
Resolved
Permanent mount, stencil vessel name, and install reflective tape to lifebuoy. LEGACY COMPONENT DESC: Stowage
Condition: Improper Installation
Due 8 February 2003
Resolved 25 February 2003
Resolution: Done
Engineering › Bilge Water Management System
Issued 8 January 2003
Resolved
Provide a visual and audible alarm to protect the shaft alley aft of the engine room.
Condition: Unknown
Due 8 February 2003
Resolved 25 February 2003
Resolution: Alarm provided.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 8 January 2003
Resolved
Provide automatic engine shutdown system required for diesel engines with an integrated alarm and override switch for restart of engines. Alarm to be visual and audible at the pilot station. LEGACY COMPONENT DESC: Operating Controls
Condition: Improper Installation
Due 8 February 2003
Resolved 25 February 2003
Resolution: Proper operation witnessed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 8 January 2003
Resolved
Provide additional B-II portable fire extinguishers (2ea) to be used as an alternative for the missing alarms and engine shutdown required in item 7 from this inspection. To be provide prior to taking passengers for hire. LEGACY COMPONENT DESC: Number
Condition: Unknown
Due 8 January 2003
Resolved 25 February 2003
Resolution: Provide on 08Jan03 and restriction removed on 25Feb03.