Inspection history · 14
15 December 2006
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2841065
11 October 2006
Administrative Inspection · Uninspected Other
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2798632
6 October 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2795206
15 December 2005
Uninspected Other
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2552144
12 February 2004
Type not recorded
No type recorded · Station Dauphin Island · USCG Heartland District (CGD-H) · Activity 2006503
9 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1985913
13 December 2003
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1967164
29 April 2003
Type not recorded
No type recorded · Station Dauphin Island · USCG Heartland District (CGD-H) · Activity 1783006
27 May 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 151850
10 January 2001
Type not recorded
No type recorded · Station Dauphin Island · USCG Heartland District (CGD-H) · Activity 1521972
28 July 2000
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 281191
12 June 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 138123
9 April 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 9414
9 November 1993
Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 4855
Fire Fighting › Fire Pumps › Casing
Issued 15 December 2005
Resolved
Repair/replace fire pump and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 December 2005
Resolved 20 December 2005
Resolution: Satisfactorily tested fire pump thru two hoses.
Stability › Watertight Integrity › General
Issued 15 December 2005
No resolution recorded
Make permenate repairs to holes on main deck fwd port and stbd.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 15 December 2005
Resolved
Duplicate deficiency
Condition: Improper/Lack of Maintenance
Due 15 December 2005
Resolved 15 December 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 15 December 2005
Resolved
Service all portable fire extinguishers.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 December 2005
Resolved 20 December 2005
Resolution: All extinguishers were serviced.
Stability › Watertight Integrity › General
Issued 15 December 2005
Resolved
Repair/Replace watertight doors port and stbd.
Action required: 705 - Other - as specified
Resolved 31 March 2006
Resolution: Caskets and dogs replaced.
Engineering › Bilge Water Management System › Not Operational
Issued 15 December 2005
Resolved
Remove bilge slops.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 December 2005
Resolved 20 December 2005
Resolution: Bilge slop were removed.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 15 December 2005
Resolved
Provide copies of all Navigation Publications/lists required by 33 CFR 164.72
Action required: 17 - Rectify deficiencies prior to departure
Due 15 December 2005
Resolved 20 December 2005
Resolution: Navigation Publications are onboard.
Fire Fighting › Fire Hoses › Number
Issued 15 December 2005
Resolved
Replace missing fire hoses.
Action required: 705 - Other - as specified
Resolved 31 March 2006
Resolution: Completed.
Stability › Watertight Integrity › General
Issued 15 December 2005
Resolved
Repair/replace main deck hatches and/or dogs, and make water tight.
Action required: 705 - Other - as specified
Resolved 31 March 2006
Resolution: Completed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 15 December 2005
Resolved
Make permanent repair to railing on 01 deck stbd fwd.
Action required: 705 - Other - as specified
Resolved 31 March 2006
Resolution: Completed.
Construction/Loadline › Structures › Deck Plating
Issued 15 December 2005
Resolved
Repair crack/fracture on O1 deck stbd fwd.
Action required: 705 - Other - as specified
Resolved 31 March 2006
Resolution: Completed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 December 2005
No resolution recorded
Re-wire/dead-end all electrical runs and replace light fixture through out vessel. Install electrical covers in ER.
Action required: 705 - Other - as specified
Engineering › Fuel Oil Service System › Tank
Issued 15 December 2005
Resolved
Determine ingress of fuel into bow void.
Action required: 705 - Other - as specified
Resolved 31 March 2006
Resolution: Due to overfill of fuel tanks.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 December 2005
Resolved
Install machinery guards on all rotating machinery.
Action required: 705 - Other - as specified
Resolved 31 March 2006
Resolution: Installed.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 15 December 2005
Resolved
Replace inoperable smoke detectors.
Action required: 705 - Other - as specified
Resolved 31 March 2006
Resolution: Replaced and installed.
Electrical › Lighting (service) › Lighting Fixture
Issued 15 December 2005
Resolved
Replace all rack lights as needed in berthing areas.
Action required: 705 - Other - as specified
Resolved 31 March 2006
Resolution: Completed.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 15 December 2005
No resolution recorded
UTV SKIMMER operated commercially without being properly documented. Prior to operating commercially, vessel must provide an updated Certificate of Documentation to MSU Galveston investigators.
Action required: 17 - Rectify deficiencies prior to departure
Stability › Watertight Integrity › General
Issued 15 December 2005
No resolution recorded
Replace hatch cover for FWD void.
Action required: 705 - Other - as specified
Navigation › Piloting/Steering › Compass Deviation Table
Issued 15 December 2005
No resolution recorded
Provide on board.
Action required: 705 - Other - as specified
Electrical › Electric Generation Source (service) › Generator
Issued 15 December 2005
No resolution recorded
Repair or replace. Unable to start.
Action required: 705 - Other - as specified
Electrical › Electric Generation Source (emergency) › Generator
Issued 15 December 2005
No resolution recorded
Repair or replace. Unable to take electrical load.
Action required: 705 - Other - as specified
Navigation › Piloting/Steering › Coast Guard Light List
Issued 28 July 2000
Resolved
NO LIGHT LIST ON BOARD THE VESSEL.
Condition: Unknown
Due 4 August 2000
Resolved 31 March 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 July 2000
Resolved
VESSEL RUNNING AND TOWING LIGHTS ARE CRACKED AND HAVE THE INPROPER BULBS INSTALLED. DOES NOT MEET REQUIREMETS FOR VISIBILITY.
Condition: Unknown
Due 4 August 2000
Resolved 31 March 2006
Engineering › Fuel Oil Storage/Transfer System › Flange
Issued 28 July 2000
Resolved
PORT AND STARBOARD WING FUEL TANKS ARE NO LONGER IN SEVICE BUT STILL CONTAIN RESIDUAL FUEL. THE ACCESS COVERS WERE UNBOLTED AND LAYING IN THE ENGINE SPACE, [name withheld] THE COVERS AS TO PREVENT A ENGINE ROOM FIRE TO BE FUELED BY THE EXTRA FUEL.
Condition: Unknown
Due 29 July 2000
Resolved 31 March 2006
Engineering › Generator (propulsion-electric) › Ground Conductor
Issued 28 July 2000
Resolved
PORT GENERATOR ALTERNATOR PROTRUDES INTO THE WALKWAY WITH NOTHING COVERINGMOVING PARTS AND BELT.
Condition: Unknown
Due 28 August 2000
Resolved 31 March 2006
Engineering › Diesel Engine (auxiliary) › Air Silencer
Issued 28 July 2000
Resolved
VESSEL HAILING PORT IS MISSING FROM THE STERN.
Condition: Unknown
Due 4 August 2000
Resolved 31 March 2006
Navigation › Piloting/Steering › Marine Charts
Issued 28 July 2000
Resolved
PROVIDE UPDATED CHARTS FOR AREA OF OPERATION.
Condition: Unknown
Due 28 August 2000
Resolved 31 March 2006