MAURY USCG vessel records
← All vessels

THRUSTER ELEVATOR

THRUSTER ELEVATOR is a 1969 offshore supply vessel. The Coast Guard has recorded 9 inspections since 2016, most recently in October 2024, along with 61 deficiencies.

Records from 2016 to 2024. Most recent: inspection, 1 October 2024.

Built
1969
Last inspected
1 October 2024
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDI8086
103080
Flag
UNITED STATES
Maury page id
psix-103080

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 8 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)40.8 ft × 22.4 ft × 4.5 ft
Registered tonnagegross 43 / net 37
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJACKUP BOAT BUILDERS INC · CAERNARVON, LA, UNITED STATES · built 1969
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORT SULPHUR, LA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it43 - Regulatory (Subpart C or D), Gross Ton
37 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 9

1 October 2024 Internal Structural Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8003941
12 September 2023 Deficiency Check · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7790103
25 May 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7685845
22 September 2022 Annual Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7559462
29 July 2021 Deficiency Check · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7256152
16 April 2020 Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6931250
31 May 2019 Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6699339
27 June 2017 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6177798
10 May 2016 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5869504

Deficiency record · 61

02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 1 October 2024 Resolved
No major repairs or alterations affecting the safety of the vessel with regard to the hull shall be made without the approval of the [name withheld] observed temporary repair located on the STBD FWD side shell. Vessel to submit repair proposal prior to commencing repairs.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 October 2024
Resolution: Temp repair was cropped out and a proper repairs were conducted. An insert 48x26 was installed, verified proper fit up and NDT.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 21 September 2023 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its COI giving consideration to provisions for a seaworthy hull. Found cracks in welds located on superstructure and on toward hatch. Found wasted deck in the main deck below the house. Repair cracks on house and forward hatch, provide repair proposal and UT shots for wastage in the engine room below decks.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 4 October 2023
Resolution: Attended vessel and witnessed satisfactory repairs and NDT of welded repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 21 September 2023 Resolved
In addition to meeting 180.130 each life float and buoyant apparatus must be stowed as required under this section. Marine Inspector found the life float to have wasted grab lines, faded international orange paint, and an improper weak link. Vessel must replace items to meet stowage standard.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 October 2023
Resolution: Received documents from vessel that vessel repainted life float, renewed grab lines and installed proper weak link for life float.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 September 2023 Resolved
Lifeline must be of dark color or be of a type certified to be resisted to deterioration from ultra violet light. Marine Inspector found lifeline on ring buoy to be deteriorated. Replace lifeline to the satisfaction of the MI.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 October 2023
Resolution: Life buoy's grab lines have been renewed.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 21 September 2023 Resolved
Vessel operated solely within 20 nm of land must be equipped with a VHF-DSC radio telephone installation meeting the requirements of 80.110(c)(2). Marine Inspector identified VHF-DSC capabilities were inoperable due to MMSI not being entered into the radio. Ensure MMSI numbers are entered into the radio and DSC capabilities functional, satisfactory to the Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 4 October 2023
Resolution: Attended vessel and witnessed MMSI number plugged into VHF-DSC radio with DSC funtion capablities.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 September 2023 Resolved
The discharge ends of vent pipes shall be fitted with removable flame screens or flame arresters and shall be of such size and design as to prevent reduction in the net cross-sectional area of the vent pipe. Marine Inspector found clogged flame screen. Vessel must clean or replace flame screen.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 October 2023
Resolution: Flame screen has been cleaned.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 22 September 2022 Resolved
1'x1' hole rusting the deck of the accommodation space above causing more wastage.Nothing in this part shall be construed as limiting the marine inspector from making such inspections as are reasonable and practicable to be assured of the seaworthiness of the vessel. Self reported: Vessel had a holed deck area approx 4'x4' iwo aft leg, submit repair plan for approval before conducting repairs, to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 November 2022
Resolution: Verified repairs.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 22 September 2022 Resolved
Nothing in this part shall be construed as limiting the marine inspector from making such inspections as are reasonable and practicable to be assured of the seaworthiness of the vessel. Vessel had multiple holes in the hull and deck: 1) Port side 1"x1" through hull in engine room. 2) STBD side engine room, top welds, contains multiple small holes spanning 2 to 3 inches. 3) STBD side overhead deck in the back engine room has a 1'x1' hole rusting the deck of the accommodation space above causing more wastage. 4) The exhaust pipe, that goes through the deck in the back aft of the engine room, is cracked all around. 5) Port and STBD side of the engine mount is wasted away and cracked. 6) Multiple wasted/cracked welds forward of the engine room. Submit repair plan for approval, before conducting repairs, and conduct a survey of the main structural members to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 November 2022
Resolution: Verified repairs.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 September 2022 Resolved
The Marine inspector shall examine the bilges and other spaces to see that there is no accumulation of oil or other matter which might create a fire hazard. Engine room had excess oil over machinery and the bilge area. Clean to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 November 2022
Resolution: Verified bilges clean.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 22 September 2022 Resolved
All electrical installations shall be in accordance with sub J. Lights in the engine room did not have covers or protection required by 46 CFR 111.75-20(b). Fix to the satisfaction of the attending Marine Inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 November 2022
Resolution: Verified lights had covers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 September 2022 Resolved
The fixed power bilge pump shall be self-priming and may be driven off the main engine or other source of power. It shall be permanently connected to the bilge main and may also be connected to the fire main. If of sufficient capacity the power bilge pump may also serve as a fire pump. Bilge pump was not mounted and was contaminated with waste oil, clean and mount bilge pump to the satisfaction of the attending Marine Inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 November 2022
Resolution: Bilge pump sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 September 2022 Resolved
Vessels shall be inspected for compliance with the standards required by this subchapter. For items not covered by standards in this subchapter, inspection shall be in accordance with standards acceptable to the Officer in Charge, Marine Inspection, as good marine practice. The rudder packing flange was not double bolted, fix to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 November 2022
Resolution: Double bolted packing flange.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 22 September 2022 Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch at the pump outlet. The pump outlet shall be fitted with a pressure gage. Fire pump was fitted with a pressure gage that is not best suitable for reading the psi. Replace to the satisfaction of the attending Marine Inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 November 2022
Resolution: Fire pump sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 September 2022 Resolved
Vessels shall be inspected for compliance with the standards required by this subchapter. For items not covered by standards in this subchapter, inspection shall be in accordance with standards acceptable to the Officer in Charge, Marine Inspection, as good marine practice. Hydraulic pipes where leaking in multiple places of the engine room; 1) the STBD front side of the engine room, 2) at the PTO off the Main Engine. Fix to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 November 2022
Resolution: No hydraulic leaks detected at time of deficiency check.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 September 2022 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 November 2022
Resolution: EAP posted.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 22 September 2022 Resolved
The inspection and maintenance of the equipment listed in paragraph (a) of this section shall be logged or otherwise documented for review by the Coast Guard upon request. Conduct and record lifesaving maintenance; last maintenance log entry was dated July 2021.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 November 2022
Resolution: Logged maintenance.
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 22 September 2022 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. Conduct and record drills; last recorded drill was July 2021.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 November 2022
Resolution: Conducted drills 10/12/2022.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 July 2021 Resolved
In general, compliance with the standards established by a recognized classification society will be considered satisfactory evidence of the structural adequacy of a vessel. Marine Inspectors (MI) noted several structural members that were wasted and/or detached. In addition, the deck plating that was recently replaced was not repaired with CG oversight. The MI noted porosity, undercut, and welds without full penetration on several areas of the repair and sections of the plating not welded to the framing. Make repairs to noted structural members and grind/reweld recent repair to the satisfaction of attending MI.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 August 2021
Resolution: Satisfactory repairs were conducted at the identified structural areas to the satisfaction of the marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 July 2021 Resolved
All machinery essential to the routine operation of the vessel shall be checked. Cranes should be inspected and tested in accordance with the requirements of API RP 2D, First Edition (Oct. 1972) with supplement 1; except that the rated load test must be performed in accordance with 46 CFR 107.260 (every 60 months). Documentation showed that a third-party technician serviced the crane two weeks ago. The crane is leaking hydraulic fluid from the ram and there is a hydraulic hose that is dry-rotted and unservicable. The load test was only conducted at minimum angle. Make repairs and test at load test al all required parameters.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 August 2021
Resolution: Hydraulic ram was repaired and damaged hoses replaced to the satisfaction of the marine inspector. All Sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 July 2021 Resolved
A vessel at anchor shall exhibit an all-round whit light. The vessel's anchor light was inoperable. Repair to satisfaction of attending MI.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 August 2021
Resolution: All around white light was repaired to the satisfaction of the marine inspector. All Sat.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 July 2021 Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Items in the vessel's first aid kit is expired. Replace expired items or procure new first aid kit.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 August 2021
Resolution: First Aid kit contents are up to date. All Sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 July 2021 Resolved
Vessel's FCC radiotelephony certificate was expired. Provide valid radiotelephony certificate to the satisfaction of the attending marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 August 2021
Resolution: Radiotelephony certificate is updated and current. All Sat.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 29 July 2021 Resolved
Vessels must comply with the requirements for a navigation receiver or manual updating of position information contained in § 80.1085(c). Vessel's DSC capable radio could not display position information. Rectify deficiency via one of the following ways: *Install new radios with built-in GPS *Connect GPS to existing radio given radio will accept
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 August 2021
Resolution: New radios were installed and connected to GPS and inspected prior to receiving updated radio telephony certificate. All Sat.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 29 July 2021 Resolved
All wiring shall be suitable for marine service. MI noted a bare wire on the MDE alternator not connected, another on the starter, and an electrical receptacle in the engine compartment with no cover.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 August 2021
Resolution: Dead end and bare wires were removed or properly secured. Electrical receptacle cover was installed. All Sat.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 29 July 2021 Resolved
Vessels in lakes, bays, and sounds service shall carry sufficient life floats or buoyant apparatus for not less than 30% of all persons on board. The vessel's owner removed the life float. Install life float or buoyant apparatus to satisfaction of MI.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 August 2021
Resolution: Life float was properly installed to the satisfaction of the marine inspector. All Sat
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 16 April 2020 Resolved
MI observed numerous corrosion issues, including holes and heavy corrosion on deck longs, framing, and side longs and plating. Vsl must be surveyed prior to MI attending to conducted a ISE for credit. Vsl is restricted from operations, but may transit to Port Sulfur to effect repairs. 46 CFR 177 17C
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 May 2020
Resolution: attained vsl sat repairs
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 April 2020 Resolved
MI observed missing report for the 5 year leg inspection. Vsl must completed/provide the missing reports/inspections for the 5 year leg inspection prior to being granted credit for a Dry Dock inspections as per Policy Letter 07-02 Vsl may transit to Port Sulfur to complete the rest of the inspection. 46 CFR 177 17C
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 May 2020
Resolution: attained vsl sat tech report
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 25 June 2019 Resolved
No satisfactory proof of drug/alcohol testing program. Provide records and equipment to satisfaction of CG Marine Inspector that vessel maintains a program. Reissued with code 16.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 July 2019
Resolution: Owner enrolled in National Consortium following CG Maritime requirements.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 18 June 2019 Resolved
Vessel Operating Manual out of date. Vessel should have updated operating manual with simple to understand details of vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2019
Resolution: Reviewed and approved operating manual IAW NVIC 8-91.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 June 2019 Resolved
No satisfactory proof of Firefighting and Man Overboard drill records. Provide record-keeping activity of sufficient fire and lifesaving drills to satisfaction of CG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2019
Resolution: Implimented record book to begin documenting drills.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 June 2019 Resolved
No satisfactory proof of Lifesaving Equipment Maintenance Records. Provide maintenance records for lifesaving equipment onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2019
Resolution: Implimented record book to begin documenting drills.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 June 2019 Resolved
Life ring buoy requires adequate length throw line. Current line does not allow for satisfactory use while the lift boat is maintaining an air gap.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2019
Resolution: Replaced with longer throw line.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 18 June 2019 Resolved
Replace floating light battery with approved type to ensure proper buoyancy and operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2019
Resolution: Approved battery installed.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 18 June 2019 Resolved
Replace retro-reflective tape with SOLAS approved type, current lifesaving equipment is using DOT traffic-type tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 June 2019
Resolution: SOLAS tape installed.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 18 June 2019 Resolved
No satisfactory proof of Fire Control/Safety Plan. Provide adequate plan to CG Marine Inspector for approval.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2019
Resolution: Plan implemented and posted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 June 2019 Resolved
Loose electrical fittings on switchboard/panelboard in operating house creating potential for electrical shock. Tighten fittings to satisfaction of CG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2019
Resolution: Tightened connections.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 June 2019 Resolved
Fuel hoses on main engine are not approved type and create a potential risk of fire. Replace hoses with J1942 hoses or that of approved type for marine fuel system to satisfaction of CG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2019
Resolution: J1942 hoses installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 June 2019 Resolved
Brackets securing fuel line on main engine are broken, allowing chafing of line. Replace brackets to satisfaction of CG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 June 2019
Resolution: Brackets tightened/corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 June 2019 Resolved
Positive lead wire connecting battery to starter has exposed wire at mounting post and is making contact that provides a potential risk of shock and/or fire.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2019
Resolution: Re routed and tightened, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 June 2019 Resolved
Shackles connecting steering cable to rudder have loose pins and are not secured with a cotter pin or other means, posing a potential loss of steering risk. Secure steering cables to satisfaction of CG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2019
Resolution: New shackles installed with cotter pins.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 June 2019 Resolved
Wiring methods in battery box are insufficient with loose wiring and pose a risk of electrical shock and/or fire. Correct to satisfaction of CG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2019
Resolution: Wiring secured, loose wiring removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 June 2019 Resolved
Flexible connections for hydraulic fluid service from tank are leaking, posing risk of an equipment malfunction while vessel is in an air gap state. Repair to satisfaction of CG Marine Inspector. Vessel relies on hydraulics for fire pump and life boat service.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2019
Resolution: Replaced hoses and clamps, leaks corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 June 2019 Resolved
Fuel tank service port has valve leaking by and no cap to prevent fuel leaking into the bilge, posing a potential risk for fire. Correct to satisfaction of CG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2019
Resolution: Valve closed and port capped, no leaks present.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 18 June 2019 Resolved
Vessel has permanently affixed, portable gasoline generator on deck in the immediate vicinity of a fuel tank vent. Operating manual should have instructions for fueling, use, and servicing of generator to include personnel and fire risk mitigation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2019
Resolution: Operating instructions for generator added to Operating Manual.
Construction/Loadline › Hull › Longitudinal Frame
Issued 27 June 2017 Resolved
Replace 02 wasted deck longitudinals and 02 wasted gussets on the port side of the main engine. 46 CFR 176.25-1(a) OLD T
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 11 August 2017
Resolution: Framing and gussets were replaced satisfactorily.
Construction/Loadline › Hull › Hull Plating
Issued 27 June 2017 Resolved
Repair pinhole in starboard side shell forward of the starboard leg. 46 CFR 176.25-1(a) OLD T
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 7 August 2017
Resolution: Pinhole in starboard side was repaired.
Engineering › Steering Gear System › Piping
Issued 27 June 2017 Resolved
Repair wasted crane and jacking system hydraulic return line. 46 CFR 176.25-1(a) OLD T
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 7 August 2017
Resolution: Hydraulic return line was replaced in noted section
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 June 2017 Resolved
Replace expired first aid kit. 46 CFR 176.25-1(a) OLD T
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 7 August 2017
Resolution: First aid kit was replaced.
Construction/Loadline › Structures › Superstructure
Issued 27 June 2017 Resolved
Repair/replace wasted door at the entrance to the superstructure and fiberglass patches on the superstructure. 46 CFR 176.25-1(a) OLD T
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 11 August 2017
Resolution: Door was replaced, however vessel has been given until next drydock to effect repairs of the superstructure
Electrical › Electric Supply System (service) › Cable
Issued 27 June 2017 Resolved
Provide metal supports for electrical runs that are currently on the deck or sagging. 46 CFR 183.01-15(b) OLD T
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 7 August 2017
Resolution: Metal supports were provided for wiring
Engineering › Lubricating Oil Service System › Gauge
Issued 27 June 2017 Resolved
Repair/replace main engine oil pressure gauge line at the connection to the main engine. 46 CFR 176.25-1(a) OLD T
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 7 August 2017
Resolution: Oil pressure gauge line was replaced satisfactorily.
Construction/Loadline › Structures › Superstructure
Issued 27 June 2017 Resolved
Repair/replace fiberglass patches on the superstructure. 46 CFR 176.25-1(a) OLD T
Action required: 705 - Other - as specified
Due 8 April 2018
Resolved 13 June 2019
Resolution: Vessel replaced superstructure.
Documentation › Certificates/Documents › Stability Letter
Issued 10 May 2016 Resolved
Stability Letter Not Available On Board
Action required: 17 - Rectify deficiencies prior to departure
Due 10 May 2016
Resolved 10 May 2016
Resolution: Stability letter found in MISLE and forwarded to vessel
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 May 2016 Resolved
Starboard running light does not display required arc of visibility.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 May 2016
Resolved 11 May 2016
Resolution: Vessel provided evidence of repoisitioning of navigation light.
Documentation › Manuals/Policy Documentation › Stability Instructions
Issued 10 May 2016 Resolved
Liftboat operating manual approval not available
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 10 May 2016
Resolution: Stability letter contains Operatiing manual Approval
Lifesaving › Lifebuoys › Approval
Issued 10 May 2016 Resolved
Lifering plug broken. Replace
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 24 May 2016
Resolution: Replaced and witnessed by attending CG Marine Inspector
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 10 May 2016 Resolved
Master does not have FCC General Marine Operators Permit
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 27 July 2016
Resolution: Received FCC Certificate.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 10 May 2016 Resolved
Vessel does not have FCC Safety Radiotelephony Certificate
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 27 July 2016
Resolution: Received FCC Certificate.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 10 May 2016 Resolved
Emergency Broadcast Placard not present or posted
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 24 May 2016
Resolution: Posted and witnessed by attending CG Marine Inspector
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 10 May 2016 Resolved
Emergency Instructions Not Posted
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 24 May 2016
Resolution: Posted and witnessed by attending CG Marine Inspector
Operations/Management › Drills/Instruction › Not Conducted
Issued 10 May 2016 Resolved
Vessel crew not available to demonstrate drills. Record of drills not available for inspection.
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 24 May 2016
Resolution: Drill condcuted and witnessed by attending CG Marine Inspector.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.