Records from 2002 to 2019. Most recent: inspection, 24 February 2019.
Inspection history · 21
24 February 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6631302
23 February 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6630922
22 February 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6632868
8 December 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6594162
27 November 2018
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6580336
24 October 2017
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6293193
19 October 2017
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6291178
16 December 2016
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6059225
11 December 2016
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6055802
21 March 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5834226
26 March 2008
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3171696
11 February 2008
ISPS III Exam · Ballast Water Examination · NPV Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3145929
20 March 2007
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2891190
15 March 2007
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2888550
24 June 2006
MARPOL Annex I Examination · MARPOL Annex V Examination · PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2689774
20 August 2005
ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2466014
18 June 2005
Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2394554
19 July 2004
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2138825
16 July 2004
ISPS II Exam
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2135246
15 September 2003
Annual Inspection · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1905527
11 October 2002
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1688557
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 12 February 2008
Resolved
Ballast Water Management records do not have documentation of sediment as required by Ballast Water Management Plan. The Ballast Water Handling Log form used is not approved by the company and not in accordance with the plan. ISM Code Part A/7
Action required: 705 - Other - as specified
Resolved 26 March 2008
Resolution: Corrected to the satisfaction of the Classification Society Representative.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 12 February 2008
Resolved
Garbage Management is not controlled in accordance with the Garbage Management Plan. The garbage containers are made of plastic and cardboard. Mixed garbage is found throughout the ship, including at the final collection point. Plastic is collected in the deck stores instead of the poop deck. Hazardous waste is specifically collected but not addressed in the plan.
Action required: 705 - Other - as specified
Resolved 26 March 2008
Resolution: Corrected to the satisfaction of the Classification Society Representative.
Operations/Management › Pollution › Reporting Discharges of Oil
Issued 12 February 2008
Resolved
SOPEP Plan does not contain local contacts as required by IMO regulations. The appendices were in were disarray and contains information that is not applicable to the vessel anymore. MARPOL I/37
Action required: 705 - Other - as specified
Resolved 26 March 2008
Resolution: Corrected to the satisfaction of the Classification Society Representative.
Fire Fighting › Structural - A Class Divisions › Corridors
Issued 12 February 2008
Resolved
Structural fire integrity compromised at several locations in accommodation spaces. Several electrical cable runs leading out of deck stores were missing fire-resistant insulation. Cable runs fro deck stores to passage way and into electrical cable duct were not filled. Wastage and a hole found in the ventilation duct in the CO2 Room and the fire control station allowing ingress of oxygen.
Action required: 705 - Other - as specified
Resolved 26 March 2008
Resolution: Corrected to the satisfaction of the Classification Society Representative.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 12 February 2008
Resolved
Maintenance of the sewage system is not conducted in accordance with manufacturer's instructions. Schedule of maintenance used by crew is supplied by operator. ISM Part A/7
Action required: 705 - Other - as specified
Resolved 26 March 2008
Resolution: Corrected to the satisfaction of the Classification Society Representative.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 12 February 2008
Resolved
Oil Transfer Procedures not in accordance with 33 CFR 155.750. The procedures do not discuss the specifics of the bunkers transferred. Sample copy of the procedures were provided the Master & C/E.
Action required: 705 - Other - as specified
Resolved 12 February 2008
Resolution: Sample copy of the procedures were provided the Master & C/E.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 22 August 2005
Resolved
On the main deck forward, the paint locker space containing flammable liquids stacked above safe levels for cans of paint. Paint cans were stacked above the CO2 nozzles.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 August 2005
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 18 June 2005
Resolved
Crew could not recover the starboard lifeboat after boat drill. Starboard side boat is the designated rescue boat. Issued deficiency Solas 2001 consolidated, Chapter III Reg 17.4. Vessel could not recover rescue boat in 5 minutes.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2005
Resolved 19 June 2005
Resolution: Cleared deficiency 19 JUN 05 after crew made adjustments to brake and demonstrated ability to recover rescue boat.
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 16 July 2004
Resolved
M/V Rosina Topic recieved LOD for inoperable ARPA radar.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 23 July 2004
Resolved 21 July 2004
Resolution: Recieved techician report from Sperry Marine [name withheld] indicating that the ARPA radar on the M/V Rosina Topic was in proper working condition.