Records from 2010 to 2025. Most recent: inspection, 14 November 2025.
Inspection history · 9
14 November 2025
PSC B · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8264440
22 August 2023
Appeal
Administrative · Commandant (CG-CVC) · Activity 7825967
21 June 2023
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7719781
29 March 2023
PSC B · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7658945
29 March 2023
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7679945
4 January 2019
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6605622
5 October 2016
ISPS II Exam · COE-Dockside
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6005383
14 April 2016
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5849891
1 October 2010
PII Safety Exam · ISPS II Exam · COE-Dockside
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3857309
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 November 2025
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. PSCO observed multiple cardboard boxes, open paint cans, and approximately 35 plastic containers containing waste oil on the 3rd deck of the engine room adjacent to fuel tanks.
Action required: 15 - Rectify deficiencies by next port
Resolved 17 November 2025
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 14 November 2025
Resolved
The purpose of this regulation is to provide means of escape so that persons on board can safely and swiftly escape to the lifeboat and liferaft embarkation deck. For this purpose, the following functional requirements shall be met: escape routes shall be maintaned in a safe condition, clear of obstacles. PSCO observed marked escape door padlocked shut from the outside, unable to be opened from the inside, on the main deck adjacent to the pain locker.
Action required: 10 - Deficiency Rectified
Resolved 14 November 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 November 2025
Resolved
On cargo ships, each lifejacket shall be fitted with a lifejacket light complying with the requirements of paragraph 2.2.3 of the Code. PSCO observed 02 lifejackets on the bridge did not have affixed lights.
Action required: 10 - Deficiency Rectified
Resolved 14 November 2025
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 21 June 2023
Resolved
The company and the ship shall comply with the requirements of the international safety management code. For the purpose of this regulation the requirements of this code shall be treated as mandatory. In meeting these requirements, the company should ensure that any nonconformity is reported, with its possible cause if known; appropriate corrective action is taken; and records of these activities are maintained (10.2).
The deficiencies observed by the PSCO and noted in #2, #3, and #4 offer objective evidence that the vessel is neither being maintained nor is in substantial compliance with the relevant conventions, calling into question the adequacy and implementation of the vessel's SMS under the ISM code. An external audit is required before the ship is from detention with a focus on the maintenance procedures for fire-fighting appliances, pollution prevention equipment,and machinery spaces.
74 SOLAS (14) IX/3.1
ISM Code 10.2.2
ISM Code 10.2.3
ISM Code 10.2.4
30AC
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 21 July 2023
Resolved 30 June 2023
Resolution: Class provided missing items from the external audit that were required.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 21 June 2023
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids.
PSCO observed an accumulation oil beneath the generators in the engine room and in the purifying flats, including oil-soaked lagging. PSCO observed oil accumulation in bilges, level was at the top of the bilge wells. PSCO observed a full mop bucket of oily water in the vicinity of the generators.
74 SOLAS (09) II-2/4.1
30AC
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 21 July 2023
Resolved 30 June 2023
Resolution: Vessel provided receipts attesting to the removal of oily water.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 21 June 2023
Resolved
The system shall be provided with arrangements to ensure that any discharge of oily mixtures is automatically stopped when the oil content of the effluent exceeds 15 ppm.
PSCO observed three-way valve of the oily water separator not functioning properly. The valve only went overboard or completely cut off, preventing the three-way valve from recirculating.
MARPOL 14.7
30AC
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 21 July 2023
Resolved 29 June 2023
Resolution: PSCO attended vessel and ran test of Oily Water Separator. Equipment was found in good working order.
07 - Fire Safety › N/A - No Subsystem › Emergency Escape Breathing Device and disposition
Issued 21 June 2023
Resolved
The purpose of this regulation is to maintain and monitor the effectiveness of the fire safety measures the ship is provided with. For this purpose, the following functional requirements shall be met: fire protection systems and fire-fighting systems and appliances shall be maintained ready for use.
PSCO requested to test two fire hoses on deck utilizing the emergency fire pump. Crew attempted to energize fire hoses while running on power from the emergency fire pump however, no stream of water was produced from either hose.
74 SOLAS (09) II-2/14.1
30AC
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 21 July 2023
Resolved 29 June 2023
Resolution: PSCO attended vessel and conducted operational test of emergency fire pump which was found in good working order.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 29 March 2023
Resolved
Means shall be provided to control leaks of flammable liquids. Vessel had an oil discharge while conducting bunker operations. Diesel oil was discharge from the STBD side Diesel Diesel oil tank through the tank vents into engine room bilge and deck containment. An unknown amount of fuel was discharged into the waterway creating a sheen alongside
the vessel.
74 Solas (20) II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 29 March 2023
Resolved 30 March 2023
Resolution: After review of the attached class report, the deficiency was rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Winches & capstans
Issued 29 March 2023
Resolved
Ships shall be provided with arrangements, equipment and fittings of sufficient safe working load to enable the safe conduct of all towing and mooring operations. Vessel's aft mooring winch is not operational.
SOLAS (2020) II-1/3.8.2
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 30 March 2023
Resolved 31 March 2023
Resolution: After review of the attached class report, the deficiency was rectified.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 29 March 2023
Resolved
The total suction head of the Emergency Fire Pump on the pump capacity under all conditions of list and trim. Vessel's emergency fire pump was unable to obtain suction when at 4.6m draft.
SOLAS (2020) II-2/10.2.2.3.1.2 / FSS CODE 12.2
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 30 March 2023
Resolved 31 March 2023
Resolution: After review of the attached class report, the deficiency was rectified.
Personnel › Certificates/Documents/Licenses › License, Chief Engineer
Issued 26 September 2010
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2010
Resolved 2 October 2010
Resolution: Rcvd updated Philipino Certificate and Marshall Island Endorsement, verified each with respective issuing agency.