Records from 2005 to 2025. Most recent: inspection, 17 December 2025.
Inspection history · 50
17 December 2025
Load Line/Change of Employment · Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8279050
9 December 2025
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8279721
6 August 2025
Drydock Exam · COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8196342
14 May 2025
Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8134760
14 January 2025
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8095109
12 September 2024
Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7999600
15 May 2023
Internal Structural Exam · Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7686163
29 March 2023
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7679945
16 December 2022
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7612493
8 November 2022
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7591350
29 July 2021
MTSA Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7271498
29 July 2020
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7018045
30 June 2020
Internal Structural Exam · Cargo Tank Internal · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6991422
19 May 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6956055
19 May 2020
Annual Inspection · MTSA Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6971137
11 July 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6745547
21 May 2018
Deficiency Check · MTSA Verification · Periodic Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6419381
1 May 2018
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6403331
30 April 2018
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6402868
20 March 2017
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6107782
18 March 2016
Load Line/Change of Employment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5836180
11 March 2016
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5831576
2 March 2016
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5825242
12 August 2015
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5213651
14 May 2015
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5125109
20 November 2014
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5027125
14 April 2014
Periodic Inspection · SIP Inspection/Audit · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4835891
4 October 2013
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4728877
6 June 2013
Annual Inspection · Internal Structural Exam · Deficiency Check · SIP Inspection/Audit
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4613076
28 September 2012
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4452654
6 February 2012
SIP Inspection/Audit · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4249782
6 September 2011
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 4137130
13 July 2010
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3794845
5 May 2010
Hull Examination · Cargo Tank Internal · Annual Inspection · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3730527
23 April 2009
MTSA Verification · Internal Structural Exam · SIP Inspection/Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3462795
7 April 2009
Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3448450
7 April 2009
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3448493
10 November 2008
Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3360654
8 November 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3360426
22 September 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3330389
11 June 2008
SIP Inspection/Audit · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3233606
22 May 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3213800
8 May 2007
SIP Initial Entry
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3175984
18 April 2007
MTSA Verification · Re-Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2909933
20 December 2006
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2843465
31 August 2006
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2765246
12 July 2006
SIP Initial Entry
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3175915
21 March 2006
MTSA Verification · Cargo Tank Internal · Internal Structural Exam · Hull Examination · COI Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2607946
6 January 2006
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2562144
2 December 2005
Construction Oversight
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2564827
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 15 September 2025
Resolved
At least one-half the total number of lifebuoys on the vessel must each be fitted with a self-igniting light approved under approval series 161.010. 01 lifebuoy light not operational. Replace light prior to permissively manned operations.
46 CFR 199.70(a)(3)(ii)
Action required: 705 - Other - as specified
Resolved 16 September 2025
Resolution: Replaced light
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 15 September 2025
Resolved
All safety and relief valves for use on pressure vessels or piping systems must be designed to meet the protection and service requirements for which they are intended and must be set to relieve at a pressure which does not exceed the “maximum allowable working pressure” of the pressure vessel or piping system. Unable to test pressure vessel relief valve due to air compressor set points.
46 CFR 54.15-10(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2025
Resolved 16 September 2025
Resolution: Replaced with new relief valve
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 15 September 2025
Resolved
Each hose also must be marked date of the latest test. All transfer hoses on board were marked with incorrect test date.
33 CFR 154.500(f)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2025
Resolved 23 September 2025
Resolution: Hoses properly marked.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 September 2024
Resolved
Each ungrounded system must be provided with a suitable sensitive ground detection system located at the respective switchboard which provides continuous indication of circuit status to ground with a provision to momentarily remove the indication device from the reference ground. MI observed the 240 distribution panel in the galley showed a ground. The ground was traced to range/oven. Vessel is required to submit a tech report attesting to the repairs being done and operational test.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2024
Resolved 2 October 2024
Resolution: Received tech report for the 240v ground detection.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 12 September 2024
No resolution recorded
The owner or operator of a marine tank vessel must provide a copy of the vapor-tightness pressure test documentation for each marine tank vessel prior to loading. Date of test must be within the preceding 12 months and conducted in accordance with the procedures.
Vessel does not use nor maintain VCS installed on-board and therefore does not have a vapor tightness certificate.
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 September 2024
Resolved
Operating generators must provide a continuous and interrupted source of power from the ships service load under normal operational conditions. MI observed on the #1 / aft generator a coolant leak. A tech was already fixing the leak when CG arrived. Vessel is required to submit a tech report attesting to repairs and sat operational test.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2024
Resolved 2 October 2024
Resolution: Received tech report for repairs made to the gen.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 September 2024
Resolved
All installations shall be of marine type engines suitable for the intended service, designed and constructed in conformance with the requirements of this sub chapter. MI observed the starboard cargo pump prime mover's coolant water filter bracket found broken. Vessel rep reported it was previously welded and broke a second time. Vessel is required to replace bracket to the satisfaction of the attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2024
Resolved 4 October 2024
Resolution: Vessel installed new coolant water bracket.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 15 May 2023
Resolved
As discussed, Repair bulkhead/longitudinal and vertical stringer and stiffiners with cracked and broken welds as marked and identified in holds 6P and 5P during 2023 ISE.
Repairs to be completed by end of next Dry Dock (07/31/2025)
46 CFR 31.10-21, 42.09-30, NVIC 7-68
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 July 2025
Resolved 10 September 2025
Resolution: Repairs made
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 7 June 2013
Resolved
Restencil fwd ring buoy.
Due 21 June 2013
Resolved 21 June 2013
Resolution: Fwd ringbuoy restenciled.
Documentation › Safety Management System › Emergency Drill/Exercise Programs
Issued 7 June 2013
Resolved
Retain record (hard copy) of inspection/drill records.
Due 21 June 2013
Resolved 21 June 2013
Resolution: Crew counseled on good recordkeeping practices.
Construction/Loadline › Hull › Stiffener
Issued 6 June 2013
Resolved
Repair all items addressed on work list dtd 07Jun13 prior to due date. Due date extended from 07JUL to 21JUL per operator request and [name withheld] approval.
Action required: 705 - Other - as specified
Due 21 July 2013
Resolved 11 July 2013
Resolution: All worklist items have been repaired and verified by CG MI.
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 8 May 2013
Resolved
Rerig stbd cargo pump engine remote shutdown cable.
Due 8 June 2013
Resolved 18 May 2013
Resolution: Cable cut and rerigged.
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 6 December 2012
Resolved
Need fire extinguisher to place next to 2nd paint locker.
Due 6 January 2013
Resolved 3 January 2013
Resolution: Marine Safety outfitted barge w/ additional fire extinguisher during annual inspection.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 6 February 2012
Resolved
During inspection of ICR# B-01, one of the life preservers had an inoperable light, the battery was replaced and the item was corrected.
Action required: 705 - Other - as specified
Resolved 28 September 2012
Resolution: Inoperable light was corrected during the exam.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 February 2012
Resolved
During inspection of ICR # B-02, the life rings had Baltimore MD printed, when the hailing port is New York, NY.
Action required: 705 - Other - as specified
Due 6 March 2012
Resolved 28 September 2012
Resolution: Receivd CR attesting that the lifebuoy was restenciled with New York as hailing port.
Operations/Management › Streamlined Inspection Program › VAP Review and Revision
Issued 6 February 2012
Resolved
During inspection of item ICR # C-03, the operator stated he, did not change the battery in the smoke detector in the galley within the past 6 months. According to the SIP, ICR # 03 states the smoke detector battery will be renewed at 6 month intervals.
Action required: 705 - Other - as specified
Resolved 6 February 2012
Resolution: Educated operator on the Company’s SIP ICR inspection criteria
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 February 2012
Resolved
During inspection of ICR # F-02 the navigation light switch board alarm sounded when the FWD anchor light energized.
Action required: 705 - Other - as specified
Due 6 March 2012
Resolved 28 September 2012
Resolution: Received CR attesting that the the alarm panel was checked and found satisactory.
Operations/Management › Cargo Transfer/Lightering › Pre-transfer Inspection
Issued 2 July 2010
Resolved
Plan approval for bulkhead modification has not been approved; therefore vsl is restricted from engaging in cargo operations.
Due 27 August 2010
Resolved 13 July 2010
Resolution: Recieved letter from MSC with approval for all modifications.
Electrical › Electrical Distribution System (service) › Cable
Issued 21 April 2006
Resolved
Wiring harness on both prime movers do not meet Class 1, Division 1, standards. As per Policy letter D8(m) 02-2005, issued 835 with completion date of 30 Aug 2006
Due 31 October 2008
Resolved 1 November 2009
Resolution: Reissued under activity 3624783.