Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)250.0 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,360 / net 1,360
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC · ASHLAND CITY, TN, UNITED STATES · built 2009
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNORFOLK, VA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 28 May 2026 · expires 31 May 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1360 - Simplified, Gross Ton 1360 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 41 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 7 other vessels inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 May 2025Resolved
Electric installations on vessels must ensure: Protection of passengers, crew, other persons, and the vessel from electrical hazards. Properly secure open wire on anchor control station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2025
Resolved 3 June 2025
Resolution: Vessel O/O corrected, terminated, and taged out wiring used for OOC anchor windlass controls, see documents for corespondance.
Reweld cracked weld in #1 starboard void on #3 longitudinal frame from bottom IWO side shell vertical.
Due 5 November 2024
Resolved 7 November 2024
Resolution: Weld Repaired
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 February 2018Resolved
JNB 22 did not complete an internal structural exam by 30Nov17 as required by the COI. Vessel must complete an internal structural exam as requird by the COI. 46CFR31.10-21(a)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2018
Resolved 20 February 2018
Resolution: Inspected #1 through #6 port and stbd voids as well as the forward rake and aft box; no discrepancies found, all sat.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 1 March 2017Resolved
Ground detection for 120v distribution line is not providing active ground detection. Repair ground detection installation and certify continuous indication of circuit status.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 8 March 2017
Resolution: While inspecting the ground detection installation, the electrical technician identified a ground within the office shelter on board. Grounding screw was removed from the neutral bar within the electrical panel, ground detection operating as designed.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 1 March 2017Resolved
Previously removed control box, for vibration reduction, created opening with electrical hazard panel to ensure protection of crew and/or maintenance personnel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 8 March 2017
Resolution: Inspected protective panel on the generator. Panel closes off the opening to electrical hazards and is of sound construction.
Electrical › Electric Generation Source (service) › Generator
Issued 10 June 2014Resolved
Prove proper operation of overspeed protection on generator IAW 46 CFR 111.12.
Action required: 705 - Other - as specified
Due 10 July 2014
Resolved 11 June 2014
Resolution: Verified proper operation of overspeed protection.
Construction/Loadline › Hull › Bottom Plating
Issued 5 June 2013Resolved
Offload all cargo and provide dive survey report detailing any damage to bottom plating due to grounding. Survey to be completed prior to returning to service.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2013
Resolved 6 June 2013
Resolution: Vessel provided results of dive survey. Divers noted bare spots with scratched paint in multiple areas, but no structural damage.
Electrical › Electric Generation Source (service) › Generator
Issued 13 March 2012Resolved
Prover proper operation of generator overspeed trip IAW 46 CFR 111.12-11 prior to cargo operation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2012
Resolution: Witnessed overspeed shutdown; all sat.
Test cargo pump pressure gage & provide proper documentation IAW 46 CFR 35.35-70(c) prior to cargo operation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2012
Resolution: Purchased and installed new pressure gages; all sat.
Construction/Loadline › Hull › Double Hull
Issued 20 September 2010Resolved
Vessel to be made available for an internal structure exam by attending CG inspector within 30 days. Instructed company representative to contact local OCMI were the vessel will be made available and ensured that a gas free certificate will need to be provided for inspection. This is followup inspection after vessel was involved in a marine casualty, pier allision, see activity narative.
Action required: 705 - Other - as specified
Due 20 October 2010
Resolved 28 September 2010
Resolution: Inspected fwd rake, 1P and 2P voids; all sat.
Recorded names · 1
JNB 22 (2010–2018). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.