MAURY USCG vessel records
← All vessels

C&M 22

Built
2009
Last inspected
24 June 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 24 June 2026
…with no type recorded13
Operational controls None recorded without a removal date
Years with a record 17 calendar years (2010–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1036585
Flag
UNITED STATES
Maury page id
psix-1036585

Documentation record

Registered dimensions (L × B × D)250.0 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,360 / net 1,360
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS INC · ASHLAND CITY, TN, UNITED STATES · built 2009
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNORFOLK, VA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 28 May 2026 · expires 31 May 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1360 - Simplified, Gross Ton
1360 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 41 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 7 other vessels inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 7

Inspection history · 41

24 June 2026 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8412936
20 May 2025 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8139178
23 October 2024 Drydock Exam · Cargo Tank Internal · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8023443
17 June 2024 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7934262
28 June 2023 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7725398
10 November 2022 Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7594294
8 April 2022 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7426464
6 May 2021 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7184483
21 December 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7114902
14 May 2020 Administrative Inspection · Periodic Inspection · MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6950262
30 October 2019 Internal Structural Exam · Hull Examination · Cargo Tank Internal
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6838431
6 August 2019 Bulk Liquid Transfer Monitor
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6774813
26 February 2019 Annual Inspection · MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6630654
17 December 2018 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6598910
31 October 2018 Bulk Liquid Transfer Monitor
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6572157
20 February 2018 MTSA Verification · Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6355925
15 February 2018 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6355872
8 March 2017 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6101021
1 March 2017 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6090588
11 May 2016 MTSA Verification · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5868066
13 May 2015 Periodic Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5120124
17 November 2014 Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5025781
10 June 2014 Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4884315
25 March 2014 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4824330
27 June 2013 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4639180
5 June 2013 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4611637
5 June 2013 Damage Survey · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4613109
1 November 2012 Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4476740
5 April 2012 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4280052
14 March 2012 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4262439
12 March 2012 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4279902
30 October 2011 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4179584
28 September 2010 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3858845
20 September 2010 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3854024
20 September 2010 Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3854037
21 May 2010 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3743657
6 May 2010 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3733313
9 April 2010 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3712836
8 February 2010 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3677120
3 February 2010 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3677694
5 January 2010 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3659561

Deficiency record · 11

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 May 2025 Resolved
Electric installations on vessels must ensure: Protection of passengers, crew, other persons, and the vessel from electrical hazards. Properly secure open wire on anchor control station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2025
Resolved 3 June 2025
Resolution: Vessel O/O corrected, terminated, and taged out wiring used for OOC anchor windlass controls, see documents for corespondance.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 23 October 2024 Resolved
Reweld cracked weld in #1 starboard void on #3 longitudinal frame from bottom IWO side shell vertical.
Due 5 November 2024
Resolved 7 November 2024
Resolution: Weld Repaired
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 February 2018 Resolved
JNB 22 did not complete an internal structural exam by 30Nov17 as required by the COI. Vessel must complete an internal structural exam as requird by the COI. 46CFR31.10-21(a)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2018
Resolved 20 February 2018
Resolution: Inspected #1 through #6 port and stbd voids as well as the forward rake and aft box; no discrepancies found, all sat.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 1 March 2017 Resolved
Ground detection for 120v distribution line is not providing active ground detection. Repair ground detection installation and certify continuous indication of circuit status.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 8 March 2017
Resolution: While inspecting the ground detection installation, the electrical technician identified a ground within the office shelter on board. Grounding screw was removed from the neutral bar within the electrical panel, ground detection operating as designed.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 1 March 2017 Resolved
Previously removed control box, for vibration reduction, created opening with electrical hazard panel to ensure protection of crew and/or maintenance personnel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 8 March 2017
Resolution: Inspected protective panel on the generator. Panel closes off the opening to electrical hazards and is of sound construction.
Electrical › Electric Generation Source (service) › Generator
Issued 10 June 2014 Resolved
Prove proper operation of overspeed protection on generator IAW 46 CFR 111.12.
Action required: 705 - Other - as specified
Due 10 July 2014
Resolved 11 June 2014
Resolution: Verified proper operation of overspeed protection.
Construction/Loadline › Hull › Bottom Plating
Issued 5 June 2013 Resolved
Offload all cargo and provide dive survey report detailing any damage to bottom plating due to grounding. Survey to be completed prior to returning to service.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2013
Resolved 6 June 2013
Resolution: Vessel provided results of dive survey. Divers noted bare spots with scratched paint in multiple areas, but no structural damage.
Electrical › Electric Generation Source (service) › Generator
Issued 13 March 2012 Resolved
Prover proper operation of generator overspeed trip IAW 46 CFR 111.12-11 prior to cargo operation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2012
Resolution: Witnessed overspeed shutdown; all sat.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Relief Valve
Issued 13 March 2012 Resolved
Test cargo relief valve & provide proper documentation IAW 46 CFR 35.35.70(b) prior to cargo operation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2012
Resolution: Witnessed cargo relief valve testing; all sat.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 13 March 2012 Resolved
Test cargo pump pressure gage & provide proper documentation IAW 46 CFR 35.35-70(c) prior to cargo operation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2012
Resolution: Purchased and installed new pressure gages; all sat.
Construction/Loadline › Hull › Double Hull
Issued 20 September 2010 Resolved
Vessel to be made available for an internal structure exam by attending CG inspector within 30 days. Instructed company representative to contact local OCMI were the vessel will be made available and ensured that a gas free certificate will need to be provided for inspection. This is followup inspection after vessel was involved in a marine casualty, pier allision, see activity narative.
Action required: 705 - Other - as specified
Due 20 October 2010
Resolved 28 September 2010
Resolution: Inspected fwd rake, 1P and 2P voids; all sat.

Recorded names · 1

JNB 22 (2010–2018). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.