Documentation record
Registered dimensions (L × B × D)60.1 ft × 24.0 ft × 8.4 ft
Registered tonnagegross 81 / net 64
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBRICE SHIPBUILDING INC · CHAUVIN, LA, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portDELTAVILLE, VA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 6 May 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it81 - Simplified, Gross Ton
64 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 36 inspections, each with its date, unit and type; 17 deficiencies with the resolution recorded against each, 2 without one; operational controls, none recorded without a removal date; 10 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 36
22 October 2025
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8256974
31 January 2025
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8072940
31 October 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8022832
10 October 2024
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8012724
14 December 2023
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7837527
23 July 2023
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7773439
22 July 2023
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7749752
5 January 2023
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7616995
23 June 2022
Internal Structural Exam · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7485167
4 February 2022
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7401612
16 December 2021
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7370635
7 January 2021
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7120423
20 August 2018
Initial Certification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6517663
9 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6505556
27 June 2016
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5925827
11 April 2016
Industry Initiated Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5922663
25 March 2014
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4824330
31 July 2013
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4710076
27 June 2013
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4639180
5 June 2013
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4611637
8 May 2013
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4586615
26 March 2013
MTSA Verification · Industry Initiated Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4556406
22 February 2013
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4537394
5 December 2012
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4496575
2 March 2012
Type not recorded
No type recorded · USCGC CAPSTAN (WYTL 65601) · USCG East District (CGD-E) · Activity 4272014
20 May 2010
Type not recorded
No type recorded · USCGC CLEAT (WYTL 65615) · USCG East District (CGD-E) · Activity 3746278
29 March 2010
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3704755
13 January 2010
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3704730
20 November 2006
MTSA Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2825644
22 June 2005
Type not recorded
No type recorded · USCGC CHOCK (WYTL 65602) · USCG East District (CGD-E) · Activity 2432586
30 March 2003
Type not recorded
No type recorded · Station Philadelphia · USCG East District (CGD-E) · Activity 1768158
8 November 2000
Uninspected Towing Vessel
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 823044
29 October 1998
Uninspected Towing Vessel
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 804837
31 October 1996
Uninspected Towing Vessel
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1166452
19 January 1995
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 723663
8 January 1995
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 126062
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 October 2025
Resolved
Stowage positions for lifejackets stowed in a berthing space or stateroom and all lifejacket containers must be marked in block capital letters and numbers with the minimum quantity, identity, and, if sizes other than adult or universal sizes are used on the vessel, the size of the lifejackets stowed inside the container.
MI observed no marking of quantity of lifejackets stowed.
46 CFR 141.340(h)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2025
Resolved 3 November 2025
Resolution: Provided photographic evidence of lifejacket quantity label.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 29 October 2025
Resolved
The frame or support of any semi-portable fire extinguisher fitted with wheels must be welded or otherwise permanently attached to a steel bulkhead or deck to prevent it from rolling under heavy sea conditions.
MI observed semi-portable with wheels was not permanently to the deck or steel bulkhead.
46 CFR 142.230(c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2025
Resolved 20 November 2025
Resolution: O/o provided photograhpic evidence of fire ext tied with line and chain.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 29 October 2025
Resolved
Piping and tanks exposed to the outside of the hull must be made of metal and maintained in a leak free condition. MI observed a failed temp repair on the washer OVBD drain leaking onto the generator exhaust.
46 CFR 143.270
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2025
Resolved 3 November 2025
Resolution: O/o provided photograhpic evidence of permanent repair of washer OVBD drain.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 29 October 2025
No resolution recorded
Each liferaft must be arranged to permit it to drop into
the water from the deck on which it is stowed. A survival craft that weights 185 kilograms (407.8 pounds) or less may be lifted not more than 300 millimeters (1 foot) in order to launch. MI observed the survival craft stowage prohibiting liferaft to drop into the water and needing to be lifted more than 1 foot. Rectify prior to next credit drydock.
46 CFR 199.130(a)(7)(ii) and (c)(3)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 November 2025 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 29 October 2025
No resolution recorded
Each towing vessel must perform the applicable tests in
Table 143.245(b) of this section. The tests required by
this section must be recorded in accordance with part
140 of this subchapter. MI observed no record of testing
fire detection system and VSL stated they do not conduct a test of the fire detection system. Rectify within 3 months of last service/test.
46 CFR 143.245(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2027
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 29 October 2025
Resolved
In addition to the immersion suits required under
paragraph (a)(1) of this section, each watch station,
work station, and industrial work site must have enough
immersion suits to equal the number of persons normally
on watch in, or assigned to, the station or site at one
time. MI observed 1 missing immersion suit and
lifejacket onboard.
46 CFR 141.350(a)(2)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2025
Resolved 20 November 2025
Resolution: O/o Provided photographic evidence of immersion suit stored in wheelhouse.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 October 2025
Resolved
Electrical components that pose an electrical hazard must be in an enclosure.
MI observed dead end wiring below wheel house.
46 CFR 143.400(g)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 29 October 2025
Resolved 29 October 2025
Resolution: Vsl representative closed off dead end wiring.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2025
Resolved
Electrical components that pose an electrical hazard must be in an enclosure.
MI observed an open junction box in the laundry room.
46 CFR 143.400(g)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 29 October 2025
Resolved 29 October 2025
Resolution: Vsl representative closed off junction box
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 October 2024
Resolved
An exposed hazard such as gears and rotating machinery, must be protected by a cover, guard or rail. Port generator's drive belt was not covered by a guard.
46 CFR 144.820
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2024
Resolved 3 December 2024
Resolution: vessel added guard to generator
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 14 December 2023
Resolved
Except as provided in paragraphs (d)(2) through (4) of this section, each towing vessel must carry the survival craft specified in Table 141.305 of this section, as appropriate for the towing vessel, in an aggregate capacity to accommodate the total number of individuals onboard. MI observed inflatable life raft with capacity less than total number of people allowed by COI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2023
Resolved 19 December 2023
Resolution: Received objective evidence a six person life raft was placed on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 December 2023
Resolved
Each lifejacket must have a lifejacket light approved under approval series 161.012 or 161.112 securely attached to the front shoulder area of the lifejacket. MI observed several lifejackets with expired lights.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2023
Resolved 16 December 2023
Resolution: Received objective evidence lights were replaced in kind.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 December 2023
Resolved
Each towing vessel must be equipped with navigation lights, shapes, and sound signals in accordance with the International Regulations for Prevention of Collisions at Sea (COLREGS) or 33 CFR part 84 as appropriate to its area of operation. MI observed inoperable aft amber towing light.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 December 2023
Resolved 14 December 2023
Resolution: Bulb was replaced in presence of CG Marine Inspector and tested satisfactorily.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 December 2023
Resolved
Each lifebuoy on a towing vessel must be approved under approval series 160.050 or 160.150. MI observed ring lifebuoys with wasted and worn retro-reflective tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2023
Resolved 18 December 2023
Resolution: Received objective evidence retro-reflective tape was replaced in kind.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 16 December 2021
Resolved
An exposed hazard such as gears and rotating machinery must be protected by a cover, guard or rail. Accessory pulley on fwd part of both main engines were not covered.
46CFR144.820
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 January 2022
Resolved 24 February 2022
Resolution: Vessel has installed satisfactory guards on both M/E power take offs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 January 2021
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Electrical wiring under bridge console in port cabinet exposed and unprotected presenting fire and shock hazards.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2021
Resolved 24 February 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 7 January 2021
Resolved
Each towing vessel must have a reliable means to provide notification when an emergency condition exists or an essential system develops problems that require attention. The following alarms must be provided: Main engine low lubricating oil pressure; main engine high cooling water temperature. Vessel did not have a safe/appropriate means to test the main engine low lubricating oil pressure or high temperature cooling water temperature.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2021
Resolved 24 February 2022
Resolution: Vessel has provided proper means of testing machinery alarms.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 9 August 2018
Resolved
Vsl is broadcasting: No AIS Ship Type.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 September 2018
Resolved 24 February 2022