Records from 1999 to 2026. Most recent: inspection, 7 July 2026.
Inspection history · 72
7 July 2026
COI Inspection · Vessel Attendance
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8397572
12 March 2026
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8358108
9 September 2025
Annual Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8230011
12 August 2024
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7977741
9 May 2024
Internal Structural Exam · In-Service Inspection · Drydock Exam · Cargo Tank Internal
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7909312
22 August 2023
Load Line/Change of Employment
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7774222
20 June 2023
Periodic Inspection · MTSA Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7718684
7 June 2022
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7620111
20 April 2022
Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7433942
19 July 2021
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7260868
23 June 2020
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6984524
21 November 2019
Bulk Liquid Transfer Monitor
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6860130
25 February 2019
Hull Examination · Periodic Inspection · Internal Structural Exam · Cargo Tank Internal
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6631938
18 October 2018
Annual Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6558587
5 December 2017
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6318243
4 December 2017
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6318036
22 November 2017
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6312014
25 April 2017
Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6132798
28 July 2016
COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5955153
20 October 2015
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5752700
6 July 2015
MTSA Verification · SIP Inspection/Audit
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5170562
4 November 2014
SIP Inspection/Audit · MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5015800
20 April 2014
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4846424
20 March 2014
Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4819469
21 September 2013
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4721521
31 July 2013
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4710076
7 November 2012
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4480180
10 July 2012
Examination of Repairs · Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4374505
9 July 2012
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4374165
28 March 2012
Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4273522
11 August 2011
COI Inspection · SIP Inspection/Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4111623
20 October 2010
MTSA Verification · SIP Inspection/Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3873610
5 January 2010
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3659183
5 January 2010
Damage Survey · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3659262
21 July 2009
Annual Inspection · MTSA Verification · SIP Inspection/Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3541325
24 March 2009
Construction Oversight · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3440526
16 March 2009
Cargo Tank Internal · Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3419160
12 November 2008
MTSA Verification · SIP Inspection/Audit · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3374434
13 February 2008
Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3147049
16 August 2007
MTSA Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3050785
15 August 2007
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3029513
8 May 2007
SIP Initial Entry
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3175990
18 October 2006
Plan Review (Other than "T")
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2803326
22 August 2006
MTSA Verification · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2754611
12 July 2006
SIP Initial Entry
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3175923
10 February 2006
Plan Review (Other than "T")
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2583253
5 January 2006
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2561137
7 September 2005
MTSA Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2486078
2 July 2005
Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2411197
1 July 2005
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2411039
24 March 2005
MTSA Verification
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2318580
29 September 2004
Annual Inspection · Internal Structural Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2202789
1 December 2003
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1957714
19 November 2003
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1950671
10 August 2003
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1871761
30 July 2003
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1861613
23 March 2003
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1763968
8 March 2003
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1756222
25 December 2002
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1722869
6 September 2002
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1676284
24 July 2002
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1651490
31 May 2002
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1624061
21 May 2002
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1624551
11 February 2002
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1485327
7 February 2002
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1484700
13 December 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1475508
1 December 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 484450
5 September 2001
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1071494
1 March 2001
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1058385
20 October 2000
Damage Survey
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 823171
5 September 2000
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 822772
7 September 1999
Hull Examination · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1420293
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 7 July 2026
Resolved
At each inspection for certification and periodic inspection the marine inspector must conduct such tests and inspections of the main propulsion and auxiliary machinery and of its associated equipment, including the fluid control systems, as they feel necessary to check safe operation. MI found broken throttle on port cargo pump. Engineers are to design and rectify throttle cable for a more permanent solution to the satisfaction of MI. 46 CFR 61.20-3(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 July 2026
Resolution: Throttle pull and cable was replaced and permanent bracket was installed. Engineer ran the cargo pump and increased rpm and decreased. All sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 July 2026
Resolved
During each inspection or re-inspection for certification, all wing voids, rakes, cofferdams, and other void spaces on tank barges must be opened and checked from on-deck for the presence of water or cargo indicating hull damage or cargo tank leakage. MI observed water in the port side void hatches 6 and 7. O/O shall have liquid removed from forward prior to July 9, 2026. 46 CFR 31.10-21(b)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 13 July 2026
Resolution: Company removed water from void space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 July 2026
Resolved
All tank vessels are subjected to the regulations in subchapter J for electrical installations and batteries,
reference 46 CFR 111.15-5. MI observed generator battery on starboard side was leaking at terminal and port side battery had corrosion around terminal. O/O shall clean battery connections or replace to the satisfaction of attending MI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 July 2026
Resolution: Crew cleaned off batteries to satisfaction of MI.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 August 2024
Resolved
Each fire extinguisher shall be marked with a number and the location where stowed shall be marked in corresponding numbers in at least 1/2 inch figures.
The fire extinguishers and stowage locations were not marked with corresponding numbers. //46 CFR 35.40-25// 50c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2024
Resolved 13 August 2024
Resolution: Vessel rectified deficiency and sent documentation and pictures for evidence.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 22 August 2023
Resolved
All tank vessels shall conform to the requirements of this subpart. Scantlings, materials, and workmanship shall be at least equivalent to the requirements of the American Bureau of Shipping or other recognized classification society.
The gooseneck vent for the #2 port wing void has a dime sized hole. Temporary repairs have been effected to the satisfaction of the Marine Inspector; permanent repairs shall be completed at the next scheduled dry dock (due NLT 30 April 2024).
Code 705 = due at next scheduled dry dock (4/30/24).
Action required: 705 - Other - as specified
Due 30 April 2024
Resolved 7 August 2024
Resolution: Vents repaired during 2024 dry dock.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 20 June 2023
Resolved
Scantlings, materials, and workmanship shall be at least equivalent to the requirements of ABS.
Hatch cover pin support for the #1P wing void, forward, is wasted through and in need of replacement/repair.
*Code 705c - due at next scheduled dry dock of 4/30/2024
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2024
Resolved 7 August 2024
Resolution: Hatch replaced and tested during 2024 dry dock.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Loading instrument
Issued 18 October 2018
Resolved
Cargo transfer hoses must be tested annually to at least 1.5 times the maximum allowable working pressure (MAWP); at a minimum MAWP of 150, as required by 46 CFR 32.50-30. Cargo hoses were tested at MAWP in accordance with the cargo pipe testing required by the Marine Safety Manual; test cargo hoses at 1.5 times minimum allowable MAWP and provide evidence to the satisfaction of the Marine Inspector.
33 CFR 156.170(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 November 2018
Resolved 28 November 2018
Resolution: Vessel rep submitted email documentation verifying that the cargo hoses onboard had been tested to 150% MAWP.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 4 December 2017
Resolved
Vessel presents an oil pollution hazard to the vessel's surronding environment due to the heavy fuel oil spilled onto the vessel from the M/V JUPITER N during bunkering operations. Vessel is to remain witin the deployed containment boom at Norfolk Southern Pier 6 until sufficient cleaning of the vessel's hull has been cleaned to the satisfaction of the attending CGMI.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 December 2017
Resolution: Vessel's hull cleaned to the satisfaction of the attending CGMI.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 28 July 2016
Resolved
If the voltage of a distribution system is less than 1,000 volts, line to line, a tank vessel must not have a grounded distribution system. Ground detected in the cargo pump engine heater circuit. 46CFR111.05-19(a).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 August 2016
Resolved 26 August 2016
Resolution: Vessel Rep provided completed Correction Report (attached). CR stated that the port side cargo pump engine block heater is "bad". Heater circuit disconnected. Further maintenance to be conducted iaw company/ vessel SIP.
Construction/Loadline › Hull › Hull Plating
Issued 10 July 2012
Resolved
Vessel operator shall submit repair proposal addressing damage to bow rake, starboard side, IWO of knuckle approximately 4' above water line. All repairs shall be completed to the satisfaction of the attending CG Marine Inspector.
Action required: 705 - Other - as specified
Due 10 July 2012
Resolved 12 July 2012
Resolution: All repairs completed.
Construction/Loadline › Hull › Hull Plating
Issued 5 January 2010
Resolved
Provide repair proposal and make proper repairs to the damaged areas in the forward rake starboard side of the vessel prior to carrying cargo.
Condition: Damaged By Earlier Event
Action required: 703 - Prior to bunkering operations
Resolved 8 January 2010
Resolution: Vessel made proper repairs; insert was inspected to include cut out, fit up and pressure test. Test sat.
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 22 August 2006
Resolved
Prove proper operation of high level and overfill alarm system. Vessel restricted from carrying product requiring the use of installed vapor recovery system/closed gauging.
Action required: 705 - Other - as specified
Due 22 September 2006
Resolved 16 August 2007
Resolution: All high level/overfill alarms plus closed gauging system removed. VCS tagged out. see narrative for details.
Lifesaving › Buoyant Apparatus › Marking
Issued 22 August 2006
Resolved
Properly label all life saving gear (Buoyant apparatus, PFDs, immersions suits, paddles) with correct name of vessel.
Due 22 September 2006
Resolved 23 August 2006
Resolution: Received confirmation from [name withheld], Vane Bros. All life saving gear restenciled with correct name.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 22 August 2006
Resolved
Conduct hydrostatic test on diesel fuel hose, stencil hose with proper data and provide documentation prior to use.
Due 22 September 2006
Resolved 23 August 2006
Resolution: Hose tested to 225psi and stenciled with correct data.
Electrical › Electric Generation Source (service) › Generator Cable
Issued 10 February 2006
Resolved
Prove adequacy of generator feeder cable.
Action required: 705 - Other - as specified
Due 17 April 2006
Resolved 15 May 2006
Resolution: Verified proper installation.
Construction/Loadline › Hull › Hull Plating
Issued 2 July 2005
Resolved
Vessel to crop and renew 4' x 3' section of forward rake hull plating and side shell frame iwo stbd side approx 10' from aft bulkhead along knuckle and crop and renew for at least 18" x 18" insert plate approx 3' forward of main damage to repair inset with a depth of 4"-6".
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 July 2005
Resolution: All repairs satisfactorily completed and pressure tested to 1.5lbs.
Construction/Loadline › Hull › Longitudinal Frame
Issued 23 September 2004
Resolved
Properly repair the cracked welds in the stbd #2 wing tank in way of the 1 SSL 5th Fr, 6&7 SSL 3rd Fr, 7th SSL 2nd Fr, 7th SSL 1st Fr.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 25 October 2004
Resolution: All welds visually inspected and were found satisfactory.
Construction/Loadline › Structures › Rake
Issued 23 September 2004
Resolved
Crop and Renew all marked areas in the Rake port side Fwd
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 25 October 2004
Resolution: All welds and plate repair were inspected and found to be satisfactory. Repair was hose tested.
Construction/Loadline › Hull › Longitudinal Frame
Issued 23 September 2004
Resolved
Properly repair all cracked welds in the #4 wing tank stbd side as marked. Crop and renew #7 SSL as marked and crop and renew all reaming areas as marked from the vert fr #1 to # 4.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 25 October 2004
Resolution: All welds were inspected and found to be satisfactory.
Construction/Loadline › Hull › Longitudinal Frame
Issued 23 September 2004
Resolved
Properly repair all cracked welds in the #5 wing tank stbd #7 SSL at 2nd Fr.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 25 October 2004
Resolution: All welds were inspected and found to be satisfactory.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 23 September 2004
Resolved
Stbd side cargo pump did not shut down when emergency stop was pulled.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 23 October 2004
Resolved 23 September 2004
Resolution: Vessel rep tightened the cable going to the pump and submitted a CR.
Deck/Cargo
Issued 20 October 2000
Resolved
BARGE RESTRICTED TO DOCKSIDE (FACILITIES) OPERATIONS ONLY. NO SHIP BUNKERING ALLOWED UNTIL ALL CARGO BOOM REPAIRS ARE COMPLETED.
Condition: Unknown
Due 20 November 2000
Resolved 19 November 2003
Resolution: Apparently this CG-835 was previously issued in error to the wrong barge.