MAURY USCG vessel records
← All vessels

NIEUW AMSTERDAM

NIEUW AMSTERDAM is a 2010 passenger vessel (inspected). The Coast Guard has recorded 67 inspections since 2016, most recently in June 2026, along with 60 deficiencies and 2 operational controls.

Records from 2016 to 2026. Most recent: inspection, 22 June 2026.

Built
2010
Last inspected
22 June 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9378450
1037449
Flag
NETHERLANDS
Maury page id
psix-1037449

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded7
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it86273 - Convention (Subpart B), Gross Ton
53711 - Convention (Subpart B), Net Ton
45088 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ST PHILLIP Passenger (Inspected) · MISLE 452164 · 1 August 2017 · activity 6277325

Inspection history · 67

22 June 2026 PSC A · COC-CVE Annual
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8410683
19 January 2026 PSC B · COC-CVE Quarterly
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8297535
26 June 2025 PSC A · COC-CVE Annual
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8165419
15 December 2024 COC-CVE Quarterly · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8047092
26 July 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7968469
27 June 2024 PSC A · Ballast Water Examination · COC-CVE Annual · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7937911
28 April 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7921775
23 April 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7917974
9 March 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7884777
17 February 2024 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7873924
7 February 2024 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7862035
17 January 2024 PSC B · COC-CVE Quarterly
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7849119
2 December 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7842544
7 August 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7762478
13 July 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7744993
6 July 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7805670
5 July 2023 PSC A · Ballast Water Examination · ISPS Exam · COC-CVE Annual
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7724027
22 June 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7763659
8 June 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7760409
24 May 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7745274
3 May 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7738869
8 March 2023 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7647469
28 February 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7643522
12 February 2023 PSC B · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7635202
4 January 2023 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7616398
28 November 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7600756
13 October 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7576791
24 August 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7542595
11 August 2022 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7531212
9 August 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7529218
14 July 2022 PSC A · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7491948
23 June 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7485459
21 June 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7483412
16 June 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7479723
14 June 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7477622
22 April 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7436212
21 March 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7415753
21 March 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7415910
9 March 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7408944
28 February 2022 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7403368
5 February 2022 COC-CVE Quarterly · PSC B · Administrative Inspection · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7389792
2 December 2021 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7361286
16 July 2021 COC-CVE Annual
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7250635
5 April 2020 In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6935552
14 December 2019 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6873742
1 November 2019 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6847173
23 October 2019 COC-CVE Annual · ISPS III Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6839780
30 September 2019 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6824538
30 September 2019 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6825079
6 September 2019 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6805710
30 August 2019 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6799199
13 May 2019 Deficiency Check · ISPS III Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6673762
7 May 2019 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6684217
6 May 2019 In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6678738
1 November 2018 ISPS III Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6566559
30 September 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6563068
4 June 2018 ISM Exam · MARPOL Annex VI Survey · In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6434130
14 May 2018 ISPS III Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6414065
10 May 2018 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6430872
23 December 2017 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6328325
4 November 2017 COC-CVE Annual · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6299717
1 August 2017 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6277325
19 July 2017 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6256536
8 May 2017 PII Safety Exam · ISPS III Exam · COC-CVE Quarterly · Ballast Water Examination
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6138456
26 February 2017 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6095284
28 October 2016 COC-CVE Annual · Ballast Water Examination · Administrative Inspection · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6031216
9 May 2016 ISPS II Exam · Ballast Water Examination · COC-CVE Quarterly
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5872718

Deficiency record · 60

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 June 2026 Resolved
Fire extinguishers shall be situated ready for use at easily visible places which can be reached quickly and easily at any time in the event of a fire, and in such a way that their serviceability is not impaired by the weather, vibration or other external factors. Portable fire extinguisers shall be provided with devices which indicate whether they have been used. PSCO observed a railing installed in a manner which did not allow access to a fire extinguisher. 74 SOLAS 20 II-2/10.3.2.4
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2026
Resolved 25 June 2026
Resolution: Fire extinguisher was placed in area unobstructed by railing.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 25 June 2026 Resolved
Before the ship leaves port and at all times during the voyage all life-saving appliances shall be in working order and ready for immediate use. Fuel shut of valves on tender boats 12 and 14 did not close when tested. 74 SOLAS 20 111/20.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2026
Resolved 25 June 2026
Resolution: 3rd engineer adjusted cabling length, satisfactorily retested remote pulls in presence of Coast Guard and Class.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 25 June 2026 Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. PSCO observed multiple crew members lacking knowledge of inventory locations and basic operation of the lifeboat. Submit a training plan prior to departure and carry out within 14 days. 74 SOLAS 20 111/19.2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2026
Resolved 25 June 2026
Resolution: First officer coordinated training for crew, all crew members for deficient lifeboats received training and demonstrated competency in inventory and operation of lifeboat.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 June 2025 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures, double-leaf doors equipped with an access for their fire integrity shall have a latch that is automatically activated by the operation of the doors when released by the system. PSCO observed fire screen doors 0C.6.03, 09.5.07, 09.5.028, 08.2.52, 05.2.39. 74 SOLAS 20 II-2/9.4.1.1.5.12.17 ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2025
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 December 2024 Resolved
Within the perimeter of such stairway enclosures, only public toilets, lockers of non-combustible material providing storage for non-hazardous safety equipment and open information counters are permitted. PSCO observed on aft crew staircase (stair case 1) on deck 6 and 7 is stored spare windows (which are not safety equipment) and is not lockers. 74 SOLAS 20 II-2/13.3.2.3
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2024
Resolved 29 December 2024
Resolution: See class report in documents.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 December 2024 Resolved
The construction of doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated. PSCO observed FSD 09.5.19, 09.5.18, 03.1.69, and 03.3.49 were A60 and did not close, thus did not prevent the passage of smoke and flame. 74 SOLAS 20 II-2/9.4.1.1.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2024
Resolved 29 December 2024
Resolution: See class report in documents.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 December 2024 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures shall be self-closing and be capable of closing with an angle of inclination of up to 3.5° opposing closure. PSCO observed Fire screen doors: 09.5.18, 09.5.19 on Deck 10 aft passenger stairwell doors leading to outside were not able to close. 74 SOLAS 20 II-2/9.4.1.1.5.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2024
Resolved 29 December 2024
Resolution: See class report in documents.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 December 2024 Resolved
Furniture in stairways shall be limited to seating and it shall be fixed. PSCO observed unfixed seating throughout all passenger staircases. 74 SOLAS 20 II-2/5.3.3
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2024
Resolved 29 December 2024
Resolution: See class report in documents.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 15 December 2024 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. Deficiencies from Vessel annual inspection Activity #7937911, (items 4 & 8) were identified (fire door corrosion & ISM), an email (dated 1JUL24) from class identified actionable items with dates to imposed due date of 27 July. Deficiencies are still present or repeated on this examination. These deficiencies have not been resolved. Requisition to replace the corroded fire was approved in July and required parts were not ordered until September 18th, with no condition of class. 74 SOLAS 20 IX/3.1 ISM Code A.10.1
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 January 2025
Resolved 29 December 2024
Resolution: See class report in documents.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 15 December 2024 Resolved
Companies, masters, and crew members each have responsibility to ensure that each crew member can make a knowledgable and informed contribution to the safe operation of the ship. PSCO observed cabin steward staff on all deck personnel were unfamiliar with location of Embassy Information. Stairway guides on midship stairway deck six, multiple personnel did not know location of phone used to report emergencies. STCW 2017 A-I/14.1
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 January 2025
Resolved 29 December 2024
Resolution: See class report in documents.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 27 June 2024 Resolved
Code: 07123. Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. While conducting Hi-Fog system test, PSCO observed two sprinkler heads that failed to release water upon activation. 74 SOLAS 20 II-2/14.2.1.2. Action Code: 17 c, which was changed to 10c.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2024
Resolution: Sprinkler heads were replaced with new heads.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 27 June 2024 Resolved
Code: 07120. The following functional requirements shall be met escape routes shall be maintained in a safe condition, clear of obstacles, PSCO observed improper stowage in the following location, A-deck IVO fire Screen door A.4.45, A Deck Stairway 8 Zone 4, Deck 3 Promenade, and a sign outside spa. 74 SOLAS 20 II-2/13.1.2. Action Code: 17 c, which was changed to 10c.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2024
Resolution: Items stored improperly were removed from indicated areas. .
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 June 2024 Resolved
Code: 07199. The damper shall be fitted with a visible indicator which shows the operating position of the damper. PSCO observed two dampers that functioned properly but did not indicate the actual operating position in the engine room. Damper 30 A-37E readout remains inoperable. 74 SOLAS 20 II-2/9.7.1.3. Action Code: 16 ac.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 June 2024
Resolution: The damper 30.A-37E indication was repaired, tested and found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 27 June 2024 Resolved
Code: 07105. Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures shall be self-closing and be capable of closing with an angle of inclination of up to 3.5deg. opposing closure. PSCO observed a FSD door from ”hydro-pool” space providing an exit to the nearby stairway enclosure, the door would not close properly when opened- the crew described the door as `corroded`. FSD 9.5.18. 74 SOLAS 20 II-2/9.4.1.1.5,1, Action Code: 16 ac.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 June 2024
Resolution: FSD 9.5.18 was repaired and made to be operational. However, it will be replaced. New door is on order. Actionable Item was accordingly imposed with due date of 27.07.24
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 27 June 2024 Resolved
Code: 07123. Fire protection systems and the fire-fighting systems and appliances shall be maintained ready for use. PSCO observed one non-operational smoke detector (83-38) in Main Laundry. 74 SOLAS 20 II-2/14.1.1., Action Code: 16 ac.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 June 2024
Resolution: The heat detector (83.38) in Main Laundry was repaired, tested and found satisfactory. The detector will be replaced as per PMS (Preventive Maintenance System) schedule.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 27 June 2024 Resolved
Code: 07123. Fire protection systems and the fire-fighting systems and appliances shall be maintained ready for use. PSCO observed three fire lockers IVO A.04.16, A.02.09, 2.1.04 that were obstructed preventing immediate access. 74 SOLAS 20 II-2/14.1.1., Action Code: 16 ac.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 June 2024
Resolution: Obstructions were removed from the fire hydrant hose lockers IVO A.04.16, A.02.09, 2.1.04. It was also checked all over the vessel and found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 27 June 2024 Resolved
Code: 07120. The means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators placed not more than 300mm above the deck at all points of the escape route, including angles and intersections. PSCO observed extinguished low location lighting in Stairway #14 on Deck 2 in Fire Zone 6. 74 SOLAS 20 II-2/13.3.2.5.1 Action Code: 16 c, which was changed to 10c.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 June 2024
Resolution: Lighting, low location lighting and photoluminescent strip indications in way of the means of escape, including stairways and exits of deck No.2 in Fire Zone 6 were repaired.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 27 June 2024 Resolved
Code: 15109. The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. PSCO observed two nozzles that did not discharge water when activated by ship’s crew. 74 SOLAS 20 IX/3.1 Action Code: 50 ac.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 June 2024
Resolution: The company’s procedure being developed. Actionable Item was accordingly imposed with due date of 27.07.24.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 June 2024 Resolved
Code: 07199. Furniture in stairway enclosure shall be limited to seating, it shall be fixed. PSCO observed unfixed seating throughout staircases on decks 3 through 13. 74 SOLAS 20 II-2 5.3.3 Action Code: 10 c.
Action required: 10 - Deficiency Rectified
Resolved 27 June 2024
Resolution: Furniture in stairway enclosure and staircases on decks No.3-13 was secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 January 2024 Resolved
Electrical installations shall be such that: the safety of passengers, crew, and ship from electrical hazards will be ensured. PSCO observed dead-end wires in A/C station 4/6 on deck 6. 74 SOLAS (04) 11-1/40.1.3 16ac
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 January 2024
Resolved 7 February 2024
Resolution: Class report received attesting to satisfactory repair.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 17 January 2024 Resolved
Passenger ships engaged on international voyages which are not short international voyages shall carry partially enclosed lifeboats complying with the requirements of section 4.6 of the Code. LSA Code 4.4.7.3; suitable handholds shall be provided or a buoyant lifeline be becketed around the outside of the lifeboat above the waterline. Lifeboats 10 and 16 on the port side have missing/torn lifelines. 74 SOLAS (20) III/21.1.1.1 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 January 2024
Resolved 7 February 2024
Resolution: Class report received attesting to satisfactory repair.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 January 2024 Resolved
The following functional requirements shall be met escape routes shall be maintained in a safe condition, clear of obstacles. PSCO observed several escape routes on I-95, both- concert stages, Hudson Room on deck 3, and High Score Club on deck 10 being blocked by misc. items (i.e. sound/music equipment, and merchandise). 74 SOLAS (20) II-2/13.1.2 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 January 2024
Resolved 17 January 2024
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 January 2024 Resolved
The construction of doors and door frames in 'A' class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated. FSD 01.6.02 and FSD 01.6.11 were blocked with stage equipment not allowing the doors to close. FSD 0A.1.125 fire hose port was damaged not allowing the port to fully close. 74 SOLAS (20) II-2/9.4.1.1.2 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 January 2024
Resolved 17 January 2024
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 January 2024 Resolved
The means of escape, including stairways and exits, the marking must enable passengers to identify the routes of escape and readily identify the escape exits. Exit signage next to cabin 10006 was missing the signage diffuser. 74 SOLAS (20) II-2/13.3.2.5.1 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 January 2024
Resolved 17 January 2024
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 January 2024 Resolved
Escape doors from public spaces that are normally latched shall be fitted with a means of quick release. Such means shall consist of a door-latching mechanism incorporating a device that releases the latch upon the application of a force inthe direction of escape flow. PSCO observed escape door next to FSD 11.3.15 equipped with a locking device that prevents the door from sliding open. 74 SOLAS (20) II-2/13.3.2.6.2 10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 17 January 2024
Resolved 17 January 2024
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 5 July 2023 Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. PSCOs observed blocked fire extingiusher #A.02.09 and a blocked fire station in the marshalling area on A-deck MVZ 2.
Condition: Invalid
Action required: 15 - Rectify deficiencies by next port
Resolved 17 July 2023
Resolution: Received Class Report attesting to rectification of deficiency.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 July 2023 Resolved
Waste receptacles shall be constructed of non-combustible materials with no openings in the sides of bottoms. PSCOs observed combustible waste receptacles being used to store combustible garbage in the main galley and mashalling area.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 July 2023
Resolution: Received Class Report attesting to rectification of deficiency.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 5 July 2023 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. 10.2.2: In meeting these requirements the company should ensure that any nonconformity is reported with its possible cause if known. SOLAS11-2 9.4.1.1.5.2 states that FSDs in MVZ bulkheads, galley boundaries and stariway enclosures shall close between 10-40 seconds. PSCOs observed at least 12 doors closing outstide of the above mentioned timeframe that were not captured in the onboard inspections conducted by the crew in early July 2023. Additionally, PSSC survey was compelted on 25June2023.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 August 2023
Resolved 4 August 2023
Resolution: Received Class Documenation from ship attesting to shipboard procedures.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 July 2023 Resolved
Fire doors in the main vertical zone bulkheads, galley boundaries and stairway enclosures, the approximate time of closure for hinged fire doors shall be no more than 40 seconds and no less than 10seconds from the beginning of their movement. The following fire screen doors closed in less than 10 seconds 07.2.44, 06.02.39,05.2.38, 5.3.27, 4.3.29,4.4.27, 3.2.74, 3.3.47,3.5.25,3.5.28, 3.5.15, 3.5.14 .
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 July 2023
Resolution: Received Class Report attesting to rectification of deficiency.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 July 2023 Resolved
Within the perimeter of such stairway enclosures, only public toilets, lockers of non-combuistible material providing storage for non-hazardious safety equipment and open information counters are permitted. IVO WTD A1 PSCOs observed numerous crates and bicycles stored improperly.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 July 2023
Resolution: Received Class Report attesting to rectification of deficiency.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 July 2023 Resolved
The means of escape, including stairways and exits shall be marked by lighting or photoluminescent strip indicators placed not more than 300MM above the deck at all points of the escape route, including angles and intersections. Low location lighting in the aft salad bar lift area was extinguished.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 6 July 2023
Resolution: Fixed during the exam
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 July 2023 Resolved
Safe escape routes shall be provided. PSCOs observed a newly implemented office space in the exploration lounge causing a room-inroom configuration. The space was outfitted with openings to allow for communiciability to the adjacent space, however it was obstructed by banners used for privacy.
Action required: 10 - Deficiency Rectified
Resolved 6 July 2023
Resolution: fixed during the exam
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 8 March 2023 Resolved
The vessel fail to submit a ANOA within 24 hours prior to arriving to San Juan, Puerto Rico.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 8 March 2023
Resolved 2 May 2023
Resolution: Vessel given Letter of Warning for failure to submit ANOA within accepted time frame.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 14 July 2022 Resolved
For determining the appropriate fire integrity standards to be applied...such spaces are classified according to their fire risk as shown in categories 1 to 14...Previously designated stage life space (A.06.03) has been converted from a Category 8 space into a store-room for various departments. Materials are being improperly stored in the designated space, not meeting the fire integrity requirements for the designated space. SOLAS 04 II-2/9.2.2.3.2.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2022
Resolved 11 August 2022
Resolution: Recieved email from class (LR) stating that the stored items have all been removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 14 July 2022 Resolved
Power-operated sliding watertight doors shall have an independent hydraulic system for each door with sufficient capacity to operate the door at least three times. Watertight door D.6, located on D-Deck, did not operate three times. The watertight door closed and then reopened only one quarter of the way before zero pressure was indicated on the gauge. SOLAS 04 II-1/15
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 19 July 2022
Resolved 11 August 2022
Resolution: Recieved email from class (LR) stating the WTD had damaged internal seals in the lowert hydraulic cylinder. The hydraulic cylinder has been repaired and the door tested and operated as required.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 14 July 2022 Resolved
All survival craft required to provide for abandonment by the total number of persons on board shall be capable of being launched with their full complement of persons and equipment within a period of 30 min from the time the abandon ship signal is given after all persons have been assembled, with lifejackets donned. Life raft deployment was timed by PSCO and the duration from the start to the point of embarkation was 9 minutes in duration. Vessel is equipped with 4 liferafts. To meet the 30 minute launching requirement, the deployment should have taken approximately 7.5 minutes. SOLAS 20 III/21.1.3
Action required: 10 - Deficiency Rectified
Resolved 14 July 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 July 2022 Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. Electrical cover for fire damper controller #61181FD was removed from its mount and was hanging from the wires. SOLAS 04 II-1/40.1.3
Action required: 10 - Deficiency Rectified
Resolved 14 July 2022
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 14 July 2022 Resolved
During preparation and launching, the survival craft, its launching appliance, and the area of the water into which is to be launched shall be adequately illuminated. 03 embarkation lights on port - 01 aft of rescue boat, 01 aft of lifeboat 18 and 01 forward of life raft station were extinguished. SOLAS 20 III/16.7
Action required: 10 - Deficiency Rectified
Resolved 14 July 2022
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 July 2022 Resolved
The construction of doors and door framed in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated. Double-leaf FSD 11.3.15 did not latch upon closing from a local means. SOLAS 04 II-2/9.4.1.1.2
Action required: 10 - Deficiency Rectified
Resolved 14 July 2022
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 5 February 2022 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The port side rescue boat was unable to deploy in a timely manner due to the track holding electrical wiring for the crane would slip and begin to fold in on itself. SOLAS 20 Ch. III, Reg. 20.2. 16ac.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2022
Resolved 22 April 2022
Resolution: Received class report attesting to repairs.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 16 July 2021 Resolved
For a period of 36 h, emergency lighting: in all service and accommodation alleyways, stairways and exits. SOLAS 04 II-1/42.2.1 PSCO discovered 20 non-operational emergency lighting in the aft theater. Action taken: 16 abc
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2021
Resolved 30 July 2021
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 16 July 2021 Resolved
Means of escape from control stations, accommodation spaces and service spaces. Normally locked doors that form part of an escape route. The use of thumb turn latches, locks and other devices that do not open then force is applied in the direction of escape are not appropriate indoors leading from public spaces. SOLAS 20 II-2/13.3.2.6.2 On deck 9 spa area has permanently locked doors in way of escape. PSCO also discovered blocked means of escape in the crew internet room. Action taken: 16 abc
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2021
Resolved 30 July 2021
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 July 2021 Resolved
Opening in bulkheads and decks in passenger ships. Fire door in main vertical zone bulkhead shall be capable of release from a position on both sides of the door. SOLAS 20 II-2/9.4.1.1.5 The magnetic holdback is inoperable on fire door 09.5.1.3, in addition, doors 02.2.74, 03.1.92, 03.2.76, 03.3.43, 04.4.37, 03.5.25 failed to latch. Action taken: 16 ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2021
Resolved 30 July 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 July 2021 Resolved
Deep-fat cooking equipment shall be fitted with the following; an automatic or manual fire extinguishing system. SOLAS 04 II-2/10.6.4.1 PSCO discovered a wasted nozzle above the main galley deep-fat fryer. Action taken: 16 abc
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2021
Resolved 30 July 2021
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 16 July 2021 Resolved
The following requirements shall govern application of the tables. Table 9.1 shall apply to category 13, store-rooms, workshops, pantries, etc. SOLAS 04 II-2/9.2.2.3.2 PSCO discovered flammable products in store room L.A. 7.01.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2021
Resolved 30 July 2021
04 - Emergency Systems › N/A - No Subsystem › Low level lighting in corridors
Issued 16 July 2021 Resolved
The means of escape, including stairways and exits, shall be marked by lighting or photo luminescent strip indicators placed not more than 300 mm above the deck at all points of the escape route, including angles and intersections. SOLAS 04 II-1/13.3.2.5.1 PSCO discovered damaged low level lighting in the vicinity of room 4003. Action taken: 16 abc
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2021
Resolved 30 July 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 July 2021 Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. SOLAS 04 II-1/40.1.3 PSCO discovered exposed wiring in A.C. Station 4.6.10 Action taken: 16 abc
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2021
Resolved 30 July 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 July 2021 Resolved
Fixed pressure water-spraying fire-extinguishing systems complying with the provisions of the FSS Code shall be installed on ship balconies where furniture and furnishings are not as defined in regulation. SOLAS 01 II-2/10.6.1.3 On deck seven both port and starboard penthouse suites, high pressure water manual activation valves are not readily accessible. Action taken: 16 abc
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2021
Resolved 30 July 2021
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 16 July 2021 Resolved
Means of escape from control stations, accommodation spaces and service spaces. In Category 2 spaces within the perimeter of the stairway enclosure, storage is not allowed. SOLAS 20 II-2/13.3.2.3 On deck A stair 8 fire zone 4 numerous storage items were found permanently stored in the stair. Action taken: 16 abc
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2021
Resolved 30 July 2021
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 16 July 2021 Resolved
On-board training in the use of the ship's life-saving appliances, including survival craft equipment, and in the use of the ship's fire-extinguishing appliances shall be given as soon as possible but not later than two weeks after the crew member joins the ship. SOLAS 20 III/19.4.4.2 Lifesaving launching crew did not prepare the controlled decent davits. Action taken: 16 abc
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2021
Resolved 30 July 2021
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 16 July 2021 Resolved
Survival craft launching and recovery arrangements. Launching appliances and area of water shall be adequately illuminated by lighting. SOLAS 20 III/16.7 Embarkation lights STBD between lifeboat 1 and 3 and aft of boat 12 and boat 2 were found extinguished. Action taken: 16 abc
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2021
Resolved 30 July 2021
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 16 July 2021 Resolved
Containment of fire. Structural fire protection requirements separating category 12 to category 5 are A-0 bulkhead. SOLAS 20 II-2/9.2.2.2.1 On deck 9 aft, near frame 50, the New York Pizza space does not have any structural fire protection boundary protecting the pizza oven area to the open deck area. Action taken: 16 abc
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2021
Resolved 30 July 2021
Resolution: See enclosed Documents.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 May 2019 Resolved
Fire doors in galley boundaries are required to be self-closing. FRS 09.2.06, a galley boundary door, was not capable of self-closing.- 74 SOLAS (02) II-2/9.4.1.1.4.1
Action required: 10 - Deficiency Rectified
Resolved 13 May 2019
Resolution: Returned and witnessed roller shutter operational.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 13 May 2019 Resolved
In all passageways, the low-location lighting should be continuous, except as interrupted by corridors and cabin doors, in order to provide a visible delineation along the escape route. The strip of low-location lighting providing continuous delineation of the escape route in the athwartships passageway on decks 4, 5, and 6 is obstructed by galley trolleys stored at these locations as authorized by SMS procedure HOT-1002. This SMS procedure states that trolleys should be so arranged so as not to obstruct "safety equipment." No exemption allowing obstruction of the low-location lighting is appended to the PSSC. 74 SOLAS (02) II-2/13.3.2.4.5 , FSS 11.2.1
Action required: 10 - Deficiency Rectified
Resolved 13 May 2019
Resolution: Returned and witnessed galley trolleys moved.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 May 2019 Resolved
Double-leaf doors equipped with a latch necessary for their fire integrity shall have a latch that is automatically activated by the operation of the doors when released by the system. FSD 0A.3.47 fails to automatically latch upon release. 74 SOLAS (02) II-2/9.4.1.1.4.12
Action required: 10 - Deficiency Rectified
Resolved 13 May 2019
Resolution: Door adjusted during COC exam and tested sat.
Operations/Management › Pollution › Changeover Not Completed Prior to ECA
Issued 4 June 2018 Resolved
2430 >% Sulfur limits w/in ECA - While ships are operating within an emission control area, the sulfur content of fuel oil used onboard ships shall not exceed 0.10% m/m on and after 01 January 2015. The documentation required by 73/78 MARPOL VI/14.6 indicates that the vessel operated on heavy fuel oil on 23 May 2018 without employing the exhaust gas cleaning system required under the terms of the Administration's exemption from the requirements of this part. - 73/78 MARPOL VI/14.4.3 - 10c
Action required: 10 - Deficiency Rectified
Resolved 4 June 2018
Resolution: EGCS started.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 4 June 2018 Resolved
2530 - Resoures and Personnel - The Company should ensure that all personnel involved in the Company's safety management system have an adequate understanding of the relevant rules, regulations, codes, and guidelines. The crew member tasked with conducting the fuel oil changeover was unable to complete the procedure in accordance with the Company's documented procedures and the MARPOL convention. - 10c - 74 SOLAS (14) IX/3.1 ISM 6.4 - 10c
Action required: 10 - Deficiency Rectified
Resolved 4 June 2018
Resolution: Cleared on the spot.
Lifesaving › Lifeboat › Hull
Issued 4 November 2017 Resolved
0610 - All life saving appliances shall be constructed with proper workmanship and materials. Tender #14 contains a patch on fwd port hull. Patch material could not be verified for material type. 74 SOLAS (2014) III/34 LSA Code 1.2.2.1 - (a)(c)
Action required: 705 - Other - as specified
Due 20 December 2017
Resolved 23 December 2017
Resolution: Received class report attesting to proper repairs to NR 14 lifeboat hull.
Fire Fighting › Structural - A Class Divisions › Door Frames
Issued 28 October 2016 Resolved
74 SOLAS (14) II-2/9.4.1.1.2 - The construction of doors and door frames in "a" class diviosns, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated. FSD 02.6.15 and 02.6.02 have gaps that exceed 12 mm.
Action required: 705 - Other - as specified
Due 6 December 2016
Resolved 28 November 2016
Resolution: Stainless steal sills were welded to the bottom of the door frame to decrease the gap between the fire door and the deck.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 28 October 2016 Resolved
74 SOLAS (14) II-2/13.3.2.5.1 - Means of escape shall be marked by lighting or photo luminescent strip indicators at all points of escape routes. Primary escape route located on deck A zone 1 and zone 2 corridor from FSD OA2.103 to FSD OA.3.81 and FSD OA.1.125 to Deck A stairway #2 are not marked with low location lighting or photo luminescent strips.
Action required: 705 - Other - as specified
Due 6 December 2016
Resolved 29 November 2016
Resolution: Photoluminescent strips were fitted throughout Deck A