Records from 2009 to 2025. Most recent: inspection, 18 September 2025.
Inspection history · 47
18 September 2025
Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8236912
31 May 2025
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8202904
1 March 2025
PSC B
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8086389
24 September 2024
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8009181
26 August 2024
CCSSC Examination · PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7989269
5 June 2024
Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7928837
20 February 2024
Administrative Inspection · PSC B · CCSSC Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7867195
28 July 2023
PSC B · CCSSC Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7753449
6 March 2023
Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7646077
24 January 2023
Administrative Inspection · PSC B · CCSSC Examination · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7625989
27 July 2022
CCSSC Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7511061
4 February 2022
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7390799
21 January 2022
PSC B · CCSSC Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7383483
20 November 2021
Random ISPS/MTSA-No PSC
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7354789
30 May 2021
CCSSC Examination · PSC B
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 7209937
13 November 2020
CCSSC Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7093584
6 May 2020
PSC B · CCSSC Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6948121
7 December 2019
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7000637
25 September 2019
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6818839
23 August 2019
PII Safety Exam · CCSSC Examination · ISPS II Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6791756
7 August 2019
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6775439
20 February 2019
CCSSC Examination · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6627794
17 August 2018
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6514831
31 July 2018
Administrative Inspection · NPV Safety Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6496161
23 July 2018
CCSSC Examination · Deficiency Check · ISPS III Exam · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6488231
12 January 2018
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6336771
6 November 2017
Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6301646
14 August 2017
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6240079
9 August 2017
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6234975
26 July 2017
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6221413
12 July 2017
Deficiency Check · CCSSC Examination · Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6204431
20 June 2016
PII Safety Exam · CCSSC Examination · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5911811
10 June 2015
PII Safety Exam · CCSSC Examination · ISPS II Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5149508
1 June 2014
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4850653
1 June 2014
COE-Offshore · ISPS II Exam · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4859499
12 April 2013
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4567799
15 February 2013
CCSSC Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4533903
15 May 2012
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4311861
3 February 2012
ISPS III Exam · CCSSC Examination · Ballast Water Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4237495
13 November 2011
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4195174
7 November 2011
Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 4183856
26 September 2011
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4154365
23 September 2011
ISPS II Exam · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4152382
14 March 2011
CCSSC Examination · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3963545
22 October 2010
Deficiency Check · CCSSC Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3875148
22 June 2010
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3773162
11 September 2009
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3591579
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 September 2025
No resolution recorded
The condition of the ship and its equipment is maintained to conform with the provisions of the code to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship persons on board or the environment. Attending MI obvserved an inoperable aft towing winch resulting from an incident that occurred on 16 September 2025. - CCSSC Ch 1. / Reg 1.11.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2025 — due date passed with no resolution recorded
Resolution: Modified Def to align with attached BV Condition of Class.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 26 August 2024
Resolved
CCSSC (1997) 4.9.5.
Every liferaft shall be stowed with its painter permanently attached to the ship and with a float-free arrangement so that the liferaft floats free and, if inflatable, inflates automatically when the ship sinks. Liferafts were incorrectly installed with the painter line attached to a shackle above the hydrostatic release instead of the weak link.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 August 2024
Resolution: PSCO witnessed satisfactory correction of the installation of the painter line connected to the weak link.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 February 2024
Resolved
All electrical installations, equipment, cables, and wiring should be so installed and protected as to reduce to a minimum any danger to persons on board. Vessel's engine room had unsecured batteries at generators, cut and unsecured wires on stbd generator, and cut/dead-end wires on port side fire alarm activation button. 95 CCSSC 2.3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2024
Resolved 5 June 2024
Resolution: Received letter from BV stating defs rectified.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 January 2023
Resolved
The owner or Master of every ship to which this Code applies shall ensure that the condition of the ship and its equipment is maintained to conform with the provisions of this Code to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship, persons on board or the environment. 02 smoke detectors in the engine room were not functional.
CCSSC (2015) 1.11.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 February 2023
Resolved 6 March 2023
Resolution: Received technicains report(attached) attesting to the proper operation of the engine room smoke detectors.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 January 2023
Resolved
Any oil or other substances flammable or harmful to the marine environment shall not be carried in other tanks or spaces which are not specially approved by the Administration for such purposes. Fuel oil was found stored in gas cans in the engine room.
CCSSC (2015) 3.20.8
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 January 2023
Resolution: PSC witnessed removal of gas cans from engine room.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 24 January 2023
Resolved
Each lifeboat shall be inspected weekly which shall at least consist of: visual inspections to ensure that they are ready for use. Sponson on lifeboat was deflated rendering the boat not ready for immediate use.
CCSSC (2015) 4.17.7.1
Action required: 15 - Rectify deficiencies by next port
Resolved 2 February 2023
Resolution: Received interim CCSSC from class allowing vessel to sail with a non SOLAS approved rescue boat no more than 60 nm from land.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 24 January 2023
Resolved
Every liferaft shall be stowed with its painter permanently attached to the ship and with a float-free arrangement so that the liferaft floats free and, if inflatable, inflates automatically when the ship sinks. Liferafts were incorrectly installed with the painter line attached directly to the hydrostatic release instead of the weak link.
CCSSC (2015) 4.9.5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 January 2023
Resolution: PSC witnessed correct installation of painter line.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 24 January 2023
Resolved
The master shall ensure that the frequency of drills performed shall not exceed the following frequencies if weather and circumstances permit: Fire Drills – monthly. No records of fire drills could be provided since March 2022.
CCSSC (2015) 7.4.3.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 January 2023
Resolution: Received reports from company of vessel's records of fire drills.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 January 2022
Resolved
The maintenance and operation of all the equipment and instillations on board for firefighting and containment of fire should be kept up to date. Heat detector is broken in galley. CCSSC 97 3.13.3
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2022
Resolved 24 January 2022
Resolution: Vessel had heat detector replaced by Liferafts Inc. of Puerto Rico
01 - Certificates & Documentation › 012 - Crew Certificates › Endorsement by flagstate
Issued 21 January 2022
Resolved
An Administration may, if circumstances require, subject to the provisions of paragraph 1, allow a seafarer to serve for a period not exceeding three months on board a ship entitled to fly its flag, while holding an appropriate and valid certificate issued and endorsed as required by another party for use on board that party' ships but which has not yet been endorsed so as to render it appropriate for service on board ships entitled to fly the flag of the Administration. Documentary proof shall be readily available that the application for an endorsement has been submitted to the Administration. Chief Engineer and Second Engineer began working on board prior to flag receiving their application for endorsement. STCW Ch. I/10.5
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 21 January 2022
Resolved 21 January 2022
Resolution: Vessel received documentation from flag that they had received thier applications.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 6 May 2020
Resolved
Deficiencies which may be deemed to pose a danger to persons, property or the environment include the failure of seafarers to hold a certificate or to provide documentary proof that an application for an endorsement has been submitted to the Administration in accordance with regulation I/10, paragraph 5. STCW I/4.2.1
Coast Guard inspectors were made aware upon arrival that the master and chief engineer both did not possess a flag state endorsement. After review, it was found that the master's contract began on board the 15th of March, 2020 and the chief engineer's contract began on board the 19th of December, 2019. Both the master and chief engineer have lacked a valid flag state endorsement since arriving on board.
Condition: Invalid
Action required: 30 - Ship detained
Resolved 7 May 2020
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 6 May 2020
Resolved
Each Administration shall hold companies responsible for the assignment of seafarers for service on their ships and shall require every such company to ensure that each seafarer holds an appropriate certificate. STCW I/14.1
The company failed to ensure its crew was properly licensed.
Condition: Invalid
Action required: 30 - Ship detained
Resolved 7 May 2020
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 August 2019
Resolved
Every fire hose shall be provided with an approved nozzle and the necessary couplings. PSCO observed fire hose on STBD side of the engine room with no nozzle.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 August 2019
Resolved 23 August 2019
Resolution: Approved nozzle provided for fire hose.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 23 August 2019
Resolved
Fire control plans shall be kept up to date. PSCO observed outdated fire control and safety plans.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2019
Resolved 25 September 2019
Resolution: VESSEL PROVIDED UP TO DATE FIRE CONTROL PLAN.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 23 August 2019
Resolved
Rescue boat shall be stowed in a state of continuous readiness for launching in not more than five minutes. PSCO observed rescue boat would not start within the required time limit.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 August 2019
Resolved 23 August 2019
Resolution: Rescue boat engine was repaired and able to start within required time.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 August 2019
Resolved
Electrical installations shall be such that the safety of personnel and ship from electrical hazards will be assured. PSCO observed multiple electrical shock hazards. Dead end wires in Machinery space, exposed open light fixtures in crew cabins and multiple broken light switches on vessel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2019
Resolved 25 September 2019
Resolution: VESSEL FIXED THE MULTIPLE EXPOSED WIRES BY INSTALLING LIGHT FIXTURES AND NEW LIGHT SWITCHES.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 23 August 2019
Resolved
Clear instructions to be followed in the event of an emergency shall be provided and exhibited in conspicuous places throughout the ship and shall specify details of the emergency alarm and action to be taken by crew or other persons on board. PSCO observed multiple versions of the emergency instructions (Station Bill) including an outdated version.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2019
Resolved 25 September 2019
Resolution: VESSEL PROVIDED AN UPDATED COPY OF THE STATION BILL AND DISPOSED OF THE OUTDATED ONES.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 23 August 2019
Resolved
Training drills shall as far as practicable be conducted as if there were an actual emergency. PSCO observed two unsatisfactory fire drills, slow reaction, crew not familiar with fire billet, lack of communication, lack of knowledge on firefighting procedures and unfamiliarity with firefighting gear.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 August 2019
Resolved 23 August 2019
Resolution: Satisfactory Fire drill conducted.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 23 August 2019
Resolved
Each survival craft and rescue boat shall be marked in accordance with the requirements of the LSA code as applicable. PSCO observed rescue boat without required markings.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2019
Resolved 25 September 2019
Resolution: VESSEL PUT REQUIRED MARKINGS ON THE RESCUE BOAT IAW LSA
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 July 2018
Resolved
0999- The owner or master of every ship to which this Code applies should ensure that: whenever an accident occurs to a ship, of which affects the safety of the ship or the efficiency or completeness of its life-saving appliances or other equipment, a request should be made immediately to the Administration responsible for issuing the relevant certificate for a survey as may be required by 1.10, be carried out as soon as practicable. Received report that M/V SENTRY allided with aid to navigation CANTINA PORT BASIN #15, buoy 33200 on 30 July 2018. Report stated that some chain from buoy wrapped itself around the shaft and 02 of the propeller blades. - CCSSC (2002) Ch.1/11.3 - 60ac
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 August 2018
Resolution: Class report submitted, stated damages found are minor and do not afffect the navigability of the ship. They found that the ship is fit and safe for sail. All is satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 23 July 2018
Resolved
0615 - Rescue boats shall be launched each month with assigned crew. Vessels rescue boat has not been launched since 26MAR18 - CCSSC (2015) CH.4.17.4 - 15c
Action required: 15 - Rectify deficiencies by next port
Resolved 25 July 2018
Resolution: MSD STT personal witness video and logs documenting the crew launching and operating rescue boat in water. Cleared 01 Deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 July 2018
Resolved
0750 - Emergency fire pump shall be positioned in safe place outside engine room and permanently connected to fire mains. Pump is permanently connected to the fire main - CCSSC (2015) CH 3.3.10.1 - 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2018
Resolved 17 August 2018
Resolution: During attendance on board, portable emergency fire pump was tested with new installed
fire hose connection at the Isolating Valve in main deck. Test was considered satisfactory
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 23 July 2018
Resolved
1730 - The condition of the ship and its equipment is maintained to this code to ensure that the ship will remain fit to proceed to sea without danger to ship, persons on board and the environment. In vessel engine room a OWS is installed. This piece of equipment is not listed on the CCSSC. Due to vessel gross tonnage OWS is not required and must be removed - CCSSC (2015) CH 1.11.1 - 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2018
Resolved 7 August 2019
Resolution: Received statements and photos attesting to the rectification of this deficiency.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 13 July 2017
Resolved
In every ship, there shall be provided for the protection of any space containing internal combustion type machinery having a total power output of 750kW and above: one of the fixed fire-extinguishing systems referred to in 3.10.1. The total machinery space kilowattage is 2,388 and no fixed extinguishing system is installed. CCSSC 3.10.3
Action required: 705 - Other - as specified
Due 12 January 2018
Resolved 12 January 2018
Resolution: Deficiency extended until 12Jan2018. Vessel Owner and class working with third party company to installed the fixed extinguishing system. Company created proposal for new system that was forwarded to class. Class reviewed the proposed plan and returned it
Personnel › Manning/Qualifications › Medical Fitness
Issued 13 July 2017
Resolved
Every seafarer holding a certificate issued under the provisions of the convention, who is serving at sea, shall also hold a valid medical certificate issued in accordance with the provisions of this regulation and of A.1/9 of the STCW Code. Two personnel assigned to the vessel do not have valid medical certificates. STCW Reg. I/9.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2017
Resolution: Received copies of valid medical certificates for both seafarers.
Lifesaving › Rescue Boat Equipment › Repair Kit (inflated rescue boat)
Issued 13 July 2017
Resolved
Life saving appliances required by this chapter shall comply with the technical specifications of the LSA Code. The rescue boat does not contain equipment required by the LSA Code. CCSSC 4.3.1, LSA Code 5.1.2.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 July 2017
Resolution: The vessel representative ordered and provided onboard all missing equipment required by the LSA Code.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 13 July 2017
Resolved
The ship in all respects will remain fit to proceed to sea without danger to the ship, persons onboard, or the environment. There was an exhaust leak in the engine room on the starboard main engine. CCSSC 1.11.1
Action required: 705 - Other - as specified
Due 10 August 2017
Resolved 9 August 2017
Resolution: Vessel fixed exhaust leak and re-installed lagging.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 13 July 2017
Resolved
Nautical charts and nautical publications such as sailing directions, list of lights, notices to mariners, tide tables, and all other nautical publications necessary for the intended voyage, shall be adequate and up to date. The vessel is not equipped with up to date current tables, coast pilot, and inland navigation rules. 74 SOLAS (2014), Ch. V / Reg. 27
Action required: 705 - Other - as specified
Due 27 July 2017
Resolved 9 August 2017
Resolution: Vessel provided required publications on board.
Operations/Management › Drills/Instruction › Not Conducted
Issued 13 July 2017
Resolved
Masters shall ensure that the frequency of drills performed shall meet the following frequencies: enclosed spaces and steering gear - quarterly. The crew have not performed the required drills.
Action required: 705 - Other - as specified
Due 12 August 2017
Resolved 9 August 2017
Resolution: Vessel showed records of completed drills.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 13 July 2017
Resolved
In all such ships, fire control plans shall be kept up to date. The current fire control plan lists one fire fighting outfit. There are two fire fighting outfits onboard. Additional fire fighting equipment was observed in the engine room and not found in the current fire control plan. CCSSC 3.13.2
Action required: 705 - Other - as specified
Due 12 August 2017
Resolved 14 August 2017
Resolution: Vessel made corrections to plans on board.
Communications › Visual Communication › Signalling Lamp
Issued 13 July 2017
Resolved
A daylight signalling lamp, or other means, to communicate by light during day and night using an energy source of electrical power not solely dependent upon the ship's power supply is required on all ships of 150 gross tonnage and upwards. There is no independent source of electrical power that meets the requirements of IMO Resolution MSC.95(72). 74 SOLAS (2014), Ch. V / Reg. 19.2.2.2
Action required: 705 - Other - as specified
Due 12 August 2017
Resolved 9 August 2017
Resolution: Vessel demonstrated signal lamp under ship and battery power.
Documentation › Safety/Response Plans/Programs › Search and Rescue Co-Op Plan
Issued 13 July 2017
Resolved
All ships shall carry an up-to-date copy of Vol. III of the International Aeronautical and Maritime Search and Rescue (IAMSAR) Manual. The vessel is not equipped with an up-to-date IAMSAR Manual. 74 SOLAS (2014), Ch. V / Reg. 21.2
Action required: 705 - Other - as specified
Due 12 August 2017
Resolved 14 August 2017
Resolution: Vessel provided current IAMSAR manual on board.
Documentation › Safety/Response Plans/Programs › Ballast Water Management Plan
Issued 13 July 2017
Resolved
The person in charge of any vessel equipped with ballast water tanks must maintain a ballast water management (BWM) plan that has been developed specifically for the vessel. The vessel does not have a ballast water plan. 33 CFR 151.2050(g)
Action required: 705 - Other - as specified
Due 21 August 2017
Resolved 6 November 2017
Resolution: Ballast Water Management Plan onboard, the plan still needs to be review by class. The vessel eliminated and blanked off all piping for their ballast water system onboard, eliminating their capabilities to ballast. Deficiency cleared
Documentation › Certificates/Documents › Permit, Other
Issued 13 July 2017
Resolved
This permit is effective from December 19, 2013 to December 18, 2018 (i.e. 5 years). It provides NPDES permit coverage nationwide for discharges incidental to the normal operation of commercial vessels greater than 79 feet in length. The vessel does not have a Vessel General Permit.
Action required: 705 - Other - as specified
Due 21 August 2017
Resolved 6 November 2017
Resolution: Approved Vessel General Permit onboard, deficiency cleared.
Documentation › Certificates/Documents › Caribbean Cargo Ship Safety Code Cert. (CCSSC)
Issued 12 July 2017
Resolved
Unless otherwise expressly provided, this Code shall apply to cargo ships of less than 500 GT incl. oil tankers & tankers, irrespective of length, engaged on int'l voyages trading in the Caribbean Trading Area. The vessel's GT is 290 & its primary operating areas is in the Caribbean Trading Area, incl. U.S. waters; however, the vessel does not have a valid Caribbean Cargo Ship Safety Certificate.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 August 2017
Resolved 6 November 2017
Resolution: Valid CCSSC onboard.
Personnel › Certificates/Documents/Licenses › License, Third Mate
Issued 20 June 2016
Resolved
0230- Al ships shall be sufficiently and efficiently manned, Vessel did not have on board one deck officer (II/1), which is required under the issued Minimum Safe Manning document. Solas 2009 V/14.1 17C
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 June 2016
Resolution: The vessel submitted the License and Flag State endorsement of a new crew member reporting on the boat.
Documentation › Certificates/Documents › Caribbean Cargo Ship Safety Code Cert. (CCSSC)
Issued 1 June 2014
Resolved
the certificates issued under 1.12 should be readily available on board for examination at all times. Load line, solas equip, solas construction, solas radio and caribbean cargo ship safety code cert on board were expired. CCSSC ch 1 part B 1.15 due to USCG
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 June 2014
Resolution: Recieved valid documents from the vessels classification society.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 15 February 2013
Resolved
1730 - The condition of the ship and its equipment is maintained to conform with the provisions of this code. The Oil Water Separator has been inoperable for the last six months. No conditions of class on board. CCSSC Code 1.11.1 - 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 March 2013
Resolved 11 April 2013
Resolution: 11 APR 2013: Received e-mail with scanned GL classification society survey report #0114328 from agent stating deficiency issued from Activity # 4558329 has been rectified. Survey report states: Upon request from owners attended vsl and tested oily water
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 23 September 2011
Resolved
A/B found not on board, so the vessel does not meet safe manning requirements. Deficiency written to be corrected prior to departure from port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 September 2011
Resolution: Attended vessel, witnessed proper documentation for A/B IAW vessels minimum safe manning document.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 23 September 2011
Resolved
Oily water separator does not function, but is not required. Vessel's owner stated that the OWS will be removed or put out of service.
Action required: 705 - Other - as specified
Due 23 October 2011
Resolved 7 November 2011
Resolution: OWS discharge piping was removed with a out of service tag, but OWS is not required. Oily water is always retained on board and sent for disposal to a regulated discharge mobile facility.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear, Timing
Issued 14 March 2011
Resolved
CCSSC 2.3 VESSELS MAIN ENGINES SHALL BE OPERABLE FOR THE SERVICE INTENDED. PORT MAIN ENGINE FOUND NOT OPERATIONAL.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 September 2011
Resolution: Engine has been replaced, class surveyor attended vessel, conducted sea trials. New engine is working properly.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 14 March 2011
Resolved
CCSSC 5.2.3.3= EPIRB SHALL BE CAPABLE OF FLOATING FREE IF THE SHIP SINKS. HYDROSTATIC RELEASE MECHANISM FOR EPIRB FOUND EXPIRED.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 September 2011
Resolution: New Hydrostatic release witnessed onboard.
Lifesaving › Lifebuoys › Serviceable
Issued 14 March 2011
Resolved
CCSSC 1.11= THE OWNER OR MASTER OF EVERY SHIP TO WHICH THIS CODE APPLIES SHALL ENSURE THE CONDITION OF THE SHIPAND ITS EQUIPMENT IS MAINTAINED TO CONFORM WITH PROVISIONS OF THIS CODE. ONE LIFE BOUY ON THE PORT SIDE FOUND WASTED.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2011
Resolution: All life buoys in question have been replaced.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 14 March 2011
Resolved
FIXED FIRE DETECTION SYSTEM AND ALARM SYSTEM SHALL COMPLY WITH THE REQUIREMENTS OF SOLAS. 02 SMOKE DETECTORS IN ENGINE ROOM FOUND INOPERABLE. IN ADDITION, CREW MEMBER CABINS ARE MISSING SMOKE DETECTORS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2011
Resolution: All smoke detectors have been replaced and smoke detectors have been installed in all crew accommodations.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 14 March 2011
Resolved
CCSSC 4.9.8.1= RESCUE BOAT SHALL BE IN A STATE OF CONTINUOUS READINESS IN NOT MORE THAN 5 MINUTES. RESCUE BOAT ENGINE FOUND INOPERABLE.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2011
Resolution: Observed proper operation of rescue boat.
Personnel › Training › Fire Fighting Basic
Issued 14 March 2011
Resolved
CCSSC 4.17.2= TRAINING DRILLS SHOULD AS FAR A PRACTIABLE BE CONDUCTED AS IF THERE WERE AN ACTUAL EMERGENCY. WHEN CONDUCTING FIRE DRILL, CREW DID NOT SEEM TO BE KNOWLEDGABLE IN HOW TO EFFICIENTLY DON FIRFIGHTING GEAR AND APPROACH THE FIRE. AFTER CONDUCTING 02 FIRE DRILLS, IT WAS DETERMINED THAT TRAINING SHALL BE CONDUCTED PRIOR TO DEPARTURE.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 September 2011
Resolution: Witnessed satisfactory fire and abandon ship drills.
Operations/Management › EPA Vessel General Permit (VGP) › 4.1.1.1-Documentation Routine Vessel Inspection
Issued 14 March 2011
Resolved
40CFR122.2= ALL VESSELS OF 79 FEET OR GREATER IN LENGTH SHALL HAVE ONBOARD A VESSEL GENERAL PERMIT. THE VESSEL OWNER STATED THAT THEY WERE NOT AWARE OF THESE REGULATIONS AND THEREFORE DO NOT HAVE A VESSEL GENERAL PERMIT AT THIS TIME.
Action required: 705 - Other - as specified
Resolved 23 September 2011
Lifesaving › Lifebuoys › Self-Activitating Smoke Signals
Issued 14 March 2011
Resolved
CCSSC 4.1.2= AT LEAST TWO OF THE LIFEBOUYS SHALL BE PROVIDED WITH SELF ACTIVATING SMOKE SIGNALS. SELF ACTIVATING SMOKE SIGNAL ON PORT SIDE FOUND BROKEN.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2011
Resolution: Smoke signal has been replaced.
Personnel › Certificates/Documents/Licenses › License, Chief Mate
Issued 14 March 2011
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2011
Resolution: New chief arrived to vessel with all valid documentation.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 22 October 2010
Resolved
Electrical Installation should be such that the safety of personnel and ship from electrical hazards will be assured. Electrical switchboard that services port and starboard ship service generators does not have non-conducting mating in front of it. Install mating to the satisfaction of attending Port State Control Officer. CCSS Code 2.26
Due 24 October 2010
Resolved 24 October 2010
Resolution: Deficiency corrected on the spot.
Construction/Loadline › Structures › Superstructure
Issued 22 October 2010
Resolved
The strength and construction of superstructures should be sufficient to withstand all foreseeable conditions of the intended service. Exhaust port for ventilating crew bathroom has rusted/deteriorated screen. Replace screen to the satisfaction of attending Port State Control Officer. CCSS Code 2.4
Action required: 705 - Other - as specified
Due 24 November 2010
Resolved 26 October 2010
Resolution: Received written attestation that rusted screen has been replaced with new screen. The deficiency has been rectified.