Records from 2010 to 2026. Most recent: inspection, 22 April 2026.
Documentation record
Registered dimensions (L × B × D)70.0 ft × 28.0 ft × 12.0 ft
Registered tonnagegross 157 / net 126
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderB & B BOATBUILDERS INC · BAYOU LA BATRE, AL, UNITED STATES · built 2009
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 April 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it157 - Simplified, Gross Ton
126 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 22
22 April 2026
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8354094
15 January 2025
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8064194
8 January 2025
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8064390
14 June 2024
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7941327
12 February 2024
COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7864511
5 December 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7833971
27 January 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7627880
23 December 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7612487
23 December 2022
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7626832
18 October 2022
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7580329
27 March 2022
TPO Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7421361
14 January 2020
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6889646
16 July 2019
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6752452
8 May 2019
Initial Certification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6679533
28 November 2017
Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6314356
19 September 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4989496
5 September 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4975488
29 April 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4846817
22 February 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4804307
26 July 2013
DAPI Audit · Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4678559
5 November 2012
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4481439
26 March 2010
DAPI Audit · Industry Initiated Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3706026
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 February 2024
Resolved
Each towing vessel must have a fire-detection system installed to detect engine room fires. The owner or managing operator must ensure the system is installed, tested, and maintained in accordance with the manufacturer's design manual. Vessel unable to demonstrate activation of heat detectors in the engine room. Provide TPO report attesting to the proper operation of heat detectors.
Action required: 60 - Rectify deficiencies prior to movement
Due 14 March 2024
Resolved 14 March 2024
Resolution: Received satisfactory TPO report.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 February 2024
Resolved
Each towing vessel must have a fire-detection system installed to detect engine room fires. The owner or managing operator must ensure the system is installed, tested, and maintained in accordance with the manufacturer's design manual. Vessel unable to demonstrate activation of heat detectors in the engine room. Provide TPO report attesting to the proper operation of heat detectors.
Action required: 60 - Rectify deficiencies prior to movement
Due 14 March 2024
Resolved 14 March 2024
Resolution: Received satisfactory TPO report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 December 2023
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. While shifting barges in the fleet vessel noticed steering was not responding as normal. Found that port rudder was missing. Vessel authorized to transit from LMR 158 to Bollinger Quick Repair to undergo permanent repairs. Vessel shall send CG TPO report. Repair to satisfaction of TPO and attending Marine Inspectors. 46 CFR 143.205(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 December 2023
Resolution: Received TPO report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 December 2022
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Vessel experienced a fire on the STBD generator. Vessel must make repairs and provide tech report prior to movement to the satisfaction of the Third Party Organization. 46 CFR 142.205(a) - 60ac
Action required: 60 - Rectify deficiencies prior to movement
Due 23 December 2022
Resolved 23 December 2022
Resolution: Received, reviewed, and accepted TPO and tech reports attesting to satisfactory repair and operation of vessel's starboard generator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 January 2020
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel.
Stbd enginesuffered an small fire at the turbo intake.
Provide necessary repair/replacement of parts needed to operate as designed, to include new lagging of the affected areas.
Provide technician report attesting to repair and proper operation of machinery, also a statement from the licensed master of propulsion opertation.
Vessel may not move until all this is done also, empty the engine toom bilge, prior to movement.
46 CFR 143.205(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 January 2020
Resolution: Technician cleaned and renewed equipment for main engines. Vessel cleaned bilges. Tech report provided certifiying vessel was restored to normal operations.
5 November 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4481439
22 February 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 4804307
29 April 2014Routine · role: Involved in a Marine Casualty · activity 4846817
23 December 2022Routine · role: Involved in a Marine Casualty · activity 7626832
14 June 2024Routine · role: Sighted in Area · activity 7941327
8 January 2025Routine · role: Involved in a Marine Casualty · activity 8064390
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source:
IIR, through 2026.