Inspection history · 26
18 November 2025
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8270565
10 July 2025
Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8182306
4 June 2025
Deficiency Check · COI Inspection · MTSA/ISPS Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8151663
23 April 2025
Internal Structural Exam · Drydock Exam · Cargo Tank Internal
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8117477
1 April 2025
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8103126
31 July 2024
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7954447
27 November 2023
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7830105
27 November 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7830295
28 March 2023
Deficiency Check · Internal Structural Exam · MTSA Verification · Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7657522
4 August 2022
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7524602
4 June 2021
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7215158
17 April 2020
Cargo Tank Internal · COI Inspection · Internal Structural Exam · MTSA Verification · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6940241
16 May 2019
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6685348
20 March 2018
Internal Structural Exam · Periodic Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6375563
24 May 2017
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6154105
11 May 2016
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5874215
24 March 2015
COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5089840
18 March 2015
Cargo Tank Internal · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5086122
21 October 2014
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5017926
20 August 2014
Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4960269
12 June 2013
Internal Structural Exam · Periodic Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4617388
25 September 2012
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4514015
22 August 2012
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4418878
5 November 2011
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4207449
13 July 2011
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4080259
22 January 2010
Cargo Tank Internal · Initial Certification · MTSA Verification · Deadweight Survey · Construction Oversight · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3700992
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 4 June 2025
Resolved
The last 1.0 meter (3.3 feet) of vapor piping upstream of the vessel vapor connection and each end of a vapor hose must be - (1) painted in the sequence of red/yellow/red... and (2)labeled with the word "VAPOR" painted in black letters at least 50.8 millimeters (2 inches) high. Vapor piping was not painted. Cargo and vapor hoses need to be stenciled.
Cite: 46 CFR 39.2001(h)
Code: 705 - prior to loading
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 9 June 2025
Resolution: Observed properly painted vapor piping and stenciling on cargo and vapor hoses. Deficiency cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 June 2025
Resolved
The material, design, construction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly connected to the engine and supplied as such, must be at least equivalent to the standards established by the ABS marine vessel rules... Lagging needs to be installed in all dry exhaust stacks and machinery, hydraulic motors, service generators, and cargo pump engines.
Cite: 46 CFR 32.35-10; 46 CFR 58.05-1
Action 16 c
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2025
Resolved 9 June 2025
Resolution: Observed lagging installed in all dry exhaust stacks and machinery. Deficiency cleared.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 4 June 2025
Resolved
... An oil tanker of 150 gross tons and above or a non oil tanker that carries 200 cubic meters or more of oil in bulk, shall also maintain an oil record book part II. Observed missing entries in oil record book part II.
Cite: 33 CFR 151.25 (a)
Action 50 c
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 July 2025
Resolution: Received copy of ORB Part II, verifying proper entries being made over the past 30 days. Deficiency cleared.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 4 June 2025
Resolved
a tank vessel...must have on board an emergency means to enable the person in charge... to stop the flow of oil or hazardous material. E-stop could not be verified during COI due to air bound fuel system (STBD cargo pump).
Cite: 33 CFR 155.780 (a)
Action: 16 c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2025
Resolved 9 June 2025
Resolution: Verified emergencys top on STBD Cargo Pump. Deficiency cleared.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 June 2025
Resolved
Each cargo tank of a tank barge must have one of the following liquid overfill protection arrangements: an intrinsically safe overfill control system. Unable to verify high level and overfill alarms during COI.
Cite: 46 CFR 39.2009(a)(2)
Action: 705 c (prior to loading)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 9 June 2025
Resolution: Verified high level and overfill alarms on all cargo tanks. Deficiency cleared.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 1 April 2025
Resolved
The last 1.0 meter (3.3 feet) of vapor piping upstream of the vessel vapor connection and each end of a vapor hose must be...(1) painted in the sequence of red/yellow/red...and (2) labeled with the word "VAPOR" painted in black leters at least 50.8 millimeters (2 inches) high. Vapor piping was not painted. Cargo and vapor hoses need to be stenciled.
Cite: 46 CFR 39.2001(h)
Code: 705c - prior to loading operations
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 9 June 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 April 2025
Resolved
The material, design, constuction, workmanship, and arrangement of main propulsion machinery and of each auxiliary, directly conencted to the endine and supplied as such, must be at least equivalent to the standard established by the ABS marine vessel rules... Lagging needs to be installed in all dry exhaust stacks and machinery, hydraulic motors, service generators, and cargo pump engines.
Cite: 46 CFR 32.35-10/ 46 CFR 58.05-1
Code: 16c
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2025
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 1 April 2025
Resolved
...An oil tanker of 150 gross tons and above or a non oil tanker that carries 200 cubic meters or more of oil in bulk shall also maintain an oil record book part II. Observed missing entriesw in oil record book part II.
Cite: 33 CFR 151.25(a)
Code: 50c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 August 2025
Resolution: vessel provided oil record book part 2
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 1 April 2025
Resolved
A tank vessel...must have on board an emergency means to enable the person in charge...to stop the flow of oil or hazardous material. E-Stop could not be verified during COI due to air bound fuel system (STBD cargo pump).
Cite: 33 CFR 155.780(a)
Code: 16c
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2025
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 April 2025
Resolved
Each cargo tank of a tank barge must have one of the following liquid overfill protection arrangements: An instrinsically safe overfill control system. Unable to verify high level and overfill alarms during COI.
Cite: 46 CFR 39.2009(a)(2)
Code: 705 c - prior to loading operations
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 9 June 2025
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 31 July 2024
Resolved
Each cargo tank of a tank barge must have a high-level indicating device, unless the barge complies with 46 CFR 39.2009(a). The high-level indicating device must... Indicate visually the level of liquid in the cargo tank when the liquid level is within a range of 1 meter (3.28 feet) of the top of the tank
Barge's 6 meter sticks were inoperable.
Rectify prior to dry dock credit.
46 CFR 39.2003
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 August 2024
Resolution: Recieved confirmation (invoice and photos)that vessel replaced meter sticks.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 28 March 2023
Resolved
Boilers, main and auxiliary machinery, and piping systems shall conform to the requirements of sub-chapter F (Marine Engineering) of this chapter. Inboard hydraulic pump engine has exhaust leak. 46 CFR 32.35-1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 April 2023
Resolution: Attended vessel and operationally tested engine. No exhaust leak present. Cleared def.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 28 March 2023
Resolved
All tank vessels are subject to the regulations contained in sub-chapter J (Electrical Engineering) of this chapter.
-Batteries are not properly secured within generator space.
-Extra batteries stowed in generator space.
-Multiple dead end wires, wiring not properly secured, and gauges are loose or not attached on auxiliary machinery in generator space.
Remove excess batteries, cap/remove dead end wiring, properly route and secure loose wiring. 46 CFR 31.35-1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 April 2023
Resolution: Attended vessel and observed no extra batteries were in the machinery space, installed batteries were properly secured and dead end wires were removed. Cleared def.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 March 2023
Resolved
No extensive alterations involving the safety of a tank vessel either in regard to hull or machinery shall be
made without the approval of the Commandant. Overhead removed and propped on wooden blocks, located on Stbd cargo pump machinery space. Re-install overhead. 46 CFR 31.10-25
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 April 2023
Resolution: Attended vessel and observed the wooden blocks have been removed and the overhead had been properly reinstalled. Cleared def.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 28 March 2023
Resolved
The requirements of § 58.10-5 (a), (c), and (d) shall apply to diesel engine installations. Engine exhausts in all machinery space require lagging from engine turbo to bulkhead/ceiling penetration. Multiple pieces of lagging missing on all engines. 46 CFR 58.10-10(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 April 2023
Resolution: Attended vessel and operationally tested engine. Verrified all exhaust lagging had been properly reinstalled. No exhaust leak present. Cleared def.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 March 2023
Resolved
All tank vessels are subject to the regulations contained in sub-chapter J (Electrical Engineering) of this chapter. Electrical switch in office space is not secured to the wall and backing nut is not installed. 46 CFR 31.35-1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 April 2023
Resolution: Attended vessel and observed electrical box in office was properly installed. Cleared def.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 March 2023
Resolved
No flammable or combustible liquids may be stowed in any accommodation, control, or service space (other than a paint locker). (d) No more than 208 liters (55 gallons) of combustible liquids may be stowed in any machinery
space. - 5 gallon buckets of oil stowed under generator space need to be moved to a machinery space or removed from vessel.
-50gal drums stowed on deck need to be moved to a machinery space or stowed in fixed container/containment. (Fixed containment/tanks require plan approval prior to installation.) 46 CFR 147.45
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 April 2023
Resolution: Vessel provided photographic evidence that the barrels had been removed. Cleared def.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 March 2023
Resolved
Each fire extinguisher shall be marked with a number and the location where stowed. All extinguishers require 1/2 inch markings.46 CFR 35.40-25
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 April 2023
Resolution: Attended vessel and observed 04 (all) extinguishers were properly marked. Cleared def.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 March 2023
Resolved
All portable and semiportable extinguishers on board tank vessels shall be of an approved type. Approved fire extinguishers require associated bracketing system. Portable fire extinguisher bracket in office missing. 46CFR34.05-10(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 April 2023
Resolution: Attended vessel and oberved all fire extinguishers were properly installed. Cleared def.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 28 March 2023
Resolved
Each prime mover must shut down automatically upon loss of lubricating pressure to the generator bearings if the generator is directly coupled to the engine. Test is required to test sensor and wiring on electrical generator prime mover. 46 CFR 111.12-1(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 April 2023
Resolution: Attended vessel and operationally tested low lube oil shut down. All sat. Cleared def.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 March 2023
Resolved
Fwd nav light stanchion is severely corroded and a unapproved temp repair has been made. Repair prior to next credit dry dock.
Action required: 705 - Other - as specified
Due 31 March 2025
Resolved 2 June 2025
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 28 March 2023
Resolved
Grind and renew cracked weld in 3 stbd void, 6th longitudinal from the bottom in 2nd bay from fwd bulkhead. Repair prior to next credit dry dock.
Action required: 705 - Other - as specified
Due 31 March 2025
Resolved 2 June 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 4 June 2021
Resolved
Gears, couplings, flywheels and all machinery capable of injuring personnel shall be provided with adequate covers or guards. The shaft between the prime mover and the generator was not properly covered.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2021
Resolved 8 June 2021
Resolution: Cleared deficiency via virtual inspection of photo evidence.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 4 June 2021
Resolved
All installations shall be of marine type engines suitable for the intended service, designed and constructed in conformance with the requirements of this sub chapter. The second generator did not have a shaft connecting the prime mover and the generator and is not readily available for use nor was it tagged out of service.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2021
Resolved 8 June 2021
Resolution: Cleared deficiency via virtual inspection of photo evidence.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 4 June 2021
Resolved
Periodic Safety tests must demonstrate the proper operation of the primary and alternate controls, alarms, … and safety controls. Systems addressed must include fire detection and extinguishing … . Tests must be conducted at periodic intervals specified by the Coast Guard to confirm that vital systems and safety features continue to operate in a safe, reliable manner.
Fire damper on house for generators would not close fully.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2021
Resolved 8 June 2021
Resolution: Cleared deficiency via virtual inspection of photo evidence.
01 - Certificates & Documentation › 013 - Documents › Cargo record book
Issued 4 June 2021
Resolved
To have a certificate of inspection endorsed to carry NLS cargo, a ship must have a cargo record book published by the Coast Guard. The vessel did not maintain a cargo record book on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2021
Resolved 8 June 2021
Resolution: Cleared deficiency via virutal proof of receipt for a Cargo Record Book.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 20 August 2014
Resolved
Each tank must have an alarm in the vent of loss of power to the alarm system of failure of electrical circuitry to the tank level sensor. Loss of power alarm is inoperable, repairs must be made ensuring blue visual alarm acknowledges loss of power to tank level sensors. (46CFR39.20-7(b)(2))
Due 3 September 2014
Resolved 5 September 2014
Resolution: Received tech report from General Marine Electric LLC, attesting to replacement of batteries and satisfactory test of the power failure alarm.
Electrical › Electric Generation Source (service) › Ground Indicator
Issued 12 June 2013
Resolved
Troubleshoot and provide electrician's report for fault in 120V ground detection system.
Due 19 June 2013
Resolved 18 June 2013
Resolution: Received electrician''s report stating the source and remedy of the ground.
Construction/Loadline › Hull › Side Shell
Issued 12 June 2013
Resolved
Complete ISE work list issued 12JUN2013
Action required: 705 - Other - as specified
Due 12 September 2013
Resolved 1 August 2013
Resolution: Verified 10 worklist items had been satisfactorily repaired.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Emergency shutdown
Issued 22 August 2012
Resolved
Unable to demonstrated overspeed shutdown on port generator due to over hull. Must demonstrate overspeed shutdown on port generator to the satisfaction of USCG
Action required: 705 - Other - as specified
Due 22 September 2012
Resolved 26 September 2012
Resolution: Witnessed overspeed shutdown.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 13 July 2011
Resolved
Vessel's generator prime movers were not equipped with an overspeed shutdown in accordance with 46 CFR 111.12-1 (b). Vessel must demonstrate compliance with requirement to the satisfaction of attending marine inspector within 30 days.
Due 12 August 2011
Resolved 8 September 2011
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Block
Issued 13 July 2011
Resolved
unable to demonstrate overspeed shutdown on port generator prime mover
Due 10 September 2011
Resolved 7 September 2011
Resolution: All Sat