Records from 2010 to 2025. Most recent: inspection, 29 September 2025.
Documentation record
Registered dimensions (L × B × D)277.4 ft × 62.0 ft × 18.5 ft
Registered tonnagegross 2,671 / net 1,688
ITC dimensions (L × B × D)277.4 ft × 62.0 ft × 18.5 ft
ITC tonnagegross 2,671 / net 1,688
BuilderORANGE SHIPBUILDING CO INC · ORANGE, TX, UNITED STATES · built 2010
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 4 February 2026 · expires 28 February 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1688 - Convention (Subpart B), Net Ton
5468 - Dead Weight, Ton
2671 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 26
29 September 2025
MARPOL Annex IV Survey · MARPOL Annex I Examination · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8235732
21 August 2025
Cargo Tank Internal · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8214867
12 November 2024
Annual Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8027706
13 September 2023
Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7752762
15 August 2022
Periodic Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7511277
14 August 2022
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7538232
6 October 2021
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7301201
6 October 2021
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7332177
5 August 2020
Cargo Tank Internal · Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7025241
23 September 2019
MTSA Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6818473
21 September 2018
Annual Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6545773
7 September 2017
MTSA Verification · Periodic Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6256165
26 September 2016
Annual Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey · MTSA/ISPS Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6010005
11 March 2016
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5831581
29 September 2015
MTSA Verification · MARPOL Annex II Examination · COI Inspection · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5731414
8 September 2015
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5724389
24 September 2014
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4990808
20 November 2013
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4756413
18 October 2013
Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4738143
17 October 2013
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4742281
10 September 2013
Internal Structural Exam · Deficiency Check · COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4711076
27 October 2012
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4479231
9 October 2012
MTSA Verification · SIP Inspection/Audit · MARPOL Annex I Examination · MARPOL Annex VI Survey · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4471394
21 November 2011
MARPOL Annex VI Survey · Annual Inspection · MARPOL Annex I Examination · SIP Inspection/Audit
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4192684
20 November 2011
Administrative Inspection · SIP Initial Entry
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4218435
20 September 2010
MARPOL Annex I Examination · MARPOL Annex VI Survey · Initial Certification · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3853657
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 November 2024
Resolved
All exposed and dangerous places such as gears and machinery shall be properly protected with covers, guards or rails in order that the danger of accidents may be minimized. The starboard generator was found without a machinery guard for rotating machinery. 46 CFR 32.02-15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2024
Resolved 5 December 2024
Resolution: Machinery guard was installed on the starboard generator.
12 - Dangerous Goods › N/A - No Subsystem › Fire protection cargo deck area
Issued 13 September 2023
Resolved
Each pressure-vacuum relief valve must be tested for venting capacity in accordance with paragraph 1.5.1.3 of API 2000 (incorporated by reference, see 46 CFR 39.1005). The test must be carried out with a flame screen fitted at the vacuum relief opening and at the discharge opening if the pressure-vacuum relief valve is not designed to ensure a minimum vapor discharge velocity of 30 meters (98.4 feet) per second. Flame screen on vacuum relief opening was found with a 1/2" to 1" inch tear that would not prevent the passage of flames.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2023
Resolved 18 September 2023
Resolution: Operator replaced flame screen.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 5 August 2020
Resolved
Each completed operation shall be signed by the person in charge of the operation concerned and completed pages shalll be signed by the master or other person in charge of the ship. Barge Oil Record Book needs these entries.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2020
Resolved 27 August 2020
Resolution: Company adminstered training to crew.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 25 September 2019
Resolved
Attending inspector identified the vessel load line and draft marks on port side to be faded and did not contrast from the vessel's hull. Paint the vessel's load lines and draft marks in white or yellow.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 September 2019
Resolution: Port and starboard load lines and draft marks painted white.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 25 September 2019
Resolved
Hydraulic leak identified around hydraulic controls for the forward centerline windlass. Identify and repair source of hydraulic fluid leak.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2019
Resolution: New hoses and fittings installed.
Construction/Loadline › Hull › Hull Plating
Issued 18 October 2013
Resolved
Conduct dive survey addressing damage to hull, present report to USCG SEC NY.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2013
Resolution: Received copy of dive survey. Uploaded copy under documents tab for reference.
Construction/Loadline › Hull › Hull Plating
Issued 18 October 2013
Resolved
Make repairs to #6 STBD void IWO bilge knuckle.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 October 2013
Resolution: Witnessed satisfactory air test of the #6 STBD void following repairs.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 10 September 2013
Resolved
There must be ground detection for each lighting system. Submit plans to Marine Safety Center (MSC) for approval and install ground detection for 120 Volt panel in machinery space. 46 CFR 111. 05-21(c)
Due 17 October 2013
Resolved 4 October 2013
Resolution: Witnessed proper installation and test of 3-phase ground detection system on 120v panel. ABS surveyor also in attendance.
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 10 September 2013
Resolved
Vessel must demonstrate proper testing of intrinsically safe overfill control system. 46 CFR 39.20-9 (b) (3)
Action required: 705 - Other - as specified
Due 1 October 2013
Resolved 4 October 2013
Resolution: Satisfactorily tested the overfill control system using a multi-meter. Tested for continuity on the high level and overfill circuits using #3 P/S cargo tank sensors. All SAT.
Construction/Loadline › Hull › Double Hull
Issued 10 September 2013
Resolved
Complete work list items from Internal Structural Exam (ISE) dated 10 SEP2013. Prior to Credit Dry Dock.
Due 21 September 2015
Resolved 21 September 2015
Resolution: Completed credit DDX
Construction/Loadline › Hull › Side Shell
Issued 27 October 2012
Resolved
Vessel struck a pier and caused a 5ft x 3ft x 6-8" inset at the port fwd rake 5ft above the water. Vessel must conduct no cargo operations after 28OCT2012 until barge is available to Coast Guard for further inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2012
Pollution Prevention/Response › Prevention Equipment › Standard Discharge Connection
Issued 21 September 2010
Resolved
Per MARPOL Annex I (2006 cons. ed), Reg 13. Oil residue tank (sludge) shall be fitted with a Standard Discharge Connection.
Due 21 October 2010
Resolved 22 September 2010
Resolution: Verified installation of Standard Discharge Connection, per MARPOL Annex I (2006 cons. ed), Reg 13.