Records from 1985 to 2001. Most recent: inspection, 15 February 2001.
Inspection history · 44
15 February 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 98305
16 January 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 33848
18 September 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 163398
30 January 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 829381
4 January 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 69601
25 August 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 29333
14 June 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 87389
8 April 1994
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1359763
31 March 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 652721
10 January 1994
Examination of Repairs · Damage Survey
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 850629
31 December 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1354522
26 October 1993
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1468739
9 March 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1150928
3 March 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1150221
15 January 1993
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1354236
12 March 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1263753
6 January 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1256180
17 December 1991
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 951033
13 August 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 939702
31 July 1991
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1249009
15 January 1991
Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1213594
12 June 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 930618
2 April 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 908027
11 January 1990
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 911179
21 July 1989
Examination of Repairs · Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1037367
6 March 1989
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1199724
22 January 1989
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1350659
4 January 1989
Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1195923
9 May 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1346488
20 April 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1341269
4 April 1988
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1301929
5 March 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1338041
13 January 1988
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1318303
16 December 1987
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1311412
29 May 1987
Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1028827
20 March 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1329682
10 March 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1316767
25 February 1987
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1315881
25 February 1987
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1320229
4 September 1986
Examination of Repairs
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1003543
24 January 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 997830
5 January 1986
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1294283
27 December 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 441676
11 December 1985
Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 993310
Construction/Loadline
Issued 10 January 1994
Resolved
CONTINUED: VOID. ALL REPAIRS MUST BE TO THE SATISFACTION OF THE COGNIZANTOCMI. VESSEL NOT AUTHORIZED TO CONDUCT ANY CARGO OPERATIONS OTHER THAN OFFLOADING PRESENT CARGO UNTIL COMPLETION OF SATISFACTORY EXAMINATIONS NO LATER THAN 15FEB94.
Condition: Unknown
Due 15 February 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 10 January 1994
Resolved
UPON COMPLETION OF DISCHARGE OF PRESENT CARGO IN HONDURAS, PROCEED TO DRYDOCK IN NEW ORLEANS, LA. THE BARGE MUST BE MADE AVAILABLE FOR AN INTERNAL STRUCTURAL AND DRYDOCK EXAMINATION. PERMANENT REPAIRS MUST BE MADE IN WAY OF THE TEMPORARY PATCH IN WAY OF #1 CARGO HOLD DOUBLE BOTTOM
Condition: Unknown
Due 15 February 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 31 December 1993
Resolved
BLANK ALL OPEN SPACES IN DISTRIBUTIONS PANEL NEXT TO GENERATOR NEXT TO WATER TIGHT DOOR.
Condition: Unknown
Due 1 January 1994
Resolved 1 January 1994
Electrical
Issued 31 December 1993
Resolved
REPLACE MISSING BREATHER ON INTAKE MANIFOLD OF EMERGENCY GENERATOR.
Condition: Unknown
Due 1 January 1994
Resolved 1 January 1994
Unknown
Issued 31 December 1993
Resolved
THOROUGHLY CLEAN EXCESS OIL AND GREASE FROM DECK IN GENERATOR ROOM AND PROPERLY DISPOSE OF MATERIAL USED IN CLEANING.
Condition: Unknown
Due 1 January 1994
Resolved 1 January 1994
Fire Fighting
Issued 31 December 1993
Resolved
REPLACE OR SERVICE DISCHARGED FIRE EXTINGUISHER IN GENERATOR ROOM.
Condition: Unknown
Due 1 January 1994
Resolved 1 January 1994
Electrical
Issued 31 December 1993
Resolved
SECURE AND REMOVE ALL LOOSE WIRING AND CABLES IN GENERATOR ROOM.
Condition: Unknown
Due 1 January 1994
Resolved 1 January 1994
Electrical
Issued 26 October 1993
Resolved
Remove and replace renewable link fuses (3) each 100 amp 600 volts in generator rm in fuse box on after bulkhead.
Condition: Unknown
Due 26 October 1993
Resolved 26 October 1993
Electrical
Issued 26 October 1993
Resolved
Repair second primary generator (aft of gen rm) and prove operation in the presence of CG inspector.
Condition: Unknown
Due 26 October 1993
Resolved 26 October 1993
Electrical
Issued 26 October 1993
Resolved
Repair exhaust manifold on emergency generator and prove operation in the presence of CG inspector.
Condition: Unknown
Due 26 October 1993
Resolved 26 October 1993
Construction/Loadline
Issued 15 January 1993
Resolved
REPAIR OR REPLACE BROKEN COUPLING BETWEEN MOTOR AND PUMP ON STARBOARD MAIN BALLAST PUMP, AND PROPERLY REALIGN PUMP SET. PROVE PROPER OPERATION TO USCG INSPECTOR.
Condition: Unknown
Due 15 January 1993
Resolved 15 January 1993
Electrical
Issued 15 January 1993
Resolved
MAKE PERMANENT REPAIRS TO INOPERABLE MAIN GENERATOR SET AND PROVE PROPER OPERATION TO USCG INSPECTOR.
Condition: Unknown
Due 15 January 1993
Resolved 15 January 1993
Engineering
Issued 15 January 1993
Resolved
MAKE PERMANENT REPAIRS TO LEAKING HOUSING ON AUXILIARY COOLING PUMP AND PROVE PROPER OPERATION TO USCG INSPECTOR.
Condition: Unknown
Due 15 January 1993
Resolved 15 January 1993
Construction/Loadline
Issued 17 December 1991
Resolved
MAKE PERMANENT REPAIRS OR REPLACE #2 COOLING PUMP HOUSING (LOCATED IN PUMP ROOM)
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Deck/Cargo
Issued 17 December 1991
Resolved
PROVIDE POSITIVE MEANS OF CLOSURE / DRAINAGE ON ALL MACHINERY OIL CONTAINMENT.
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Deck/Cargo
Issued 17 December 1991
Resolved
PERFORM HYDROTEST ON THREE AIR RECEIVERS AND PROVIDE DOCUMENTATION ATTESTING TO THE SETTINGS OF AIR RECEIVERS RELIEF VALVES
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Construction/Loadline
Issued 15 January 1991
Resolved
PRIOR TO LOADING CARGO, INSTALL PLIMSOL MARKS PORT AND STARBOARD.
Condition: Unknown
Due 15 January 1991
Resolved 15 January 1991
Construction/Loadline
Issued 12 June 1990
Resolved
MAKE BARGE AVAILABLE FOR INSPECTION AT NEXT DRYDOCK.
Condition: Unknown
Due 12 June 1990
Resolved 12 June 1990
Electrical
Issued 11 January 1990
Resolved
PROVIDE GENERATOR FUEL TANK SIGHT GLASS WITH PROTECTIVE GUARD.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Accommodation/Occupational Safety
Issued 11 January 1990
Resolved
MAKE AIR TANKS AVAILABLE FOR INTERNAL INSPECTION. CONDUCT POP TESTS OF TANKS' PRESSURE RELIEF DEVICES.
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Electrical
Issued 11 January 1990
Resolved
INSTALL AND PROVE PROPER OPERATION OF OVERSPEED DEVICE AND AUTOMATIC SHUT- DOWN FOR LOSS OF LUBE OIL PRESSURE ON S/S GENERATORS AS PER 46 CFR 111.12-1
Condition: Unknown
Due 11 January 1990
Resolved 11 January 1990
Electrical
Issued 6 March 1989
Resolved
INSTALL SHIPS SERVICE GENERATOR THAT IS PRESENTLY IN THE SHOP BEING REPAIRED AND PROVE OPERATION TO THE COGNIZANT OCMI. 46 CFR 58.10-10 (A).
Condition: Unknown
Due 6 March 1989
Resolved 6 March 1989
Construction/Loadline
Issued 4 January 1989
Resolved
MAKE PERNAMENT REPAIRS TO DAMAGE IN WAY OF #3 STBD VOID. BARGE PERMITTED TO PROCEED FROM MOBILE, AL. TO NEW ORLEANS, LA. IN BALLAST FOR PURPOSE OF MAKING REPAIRS.
Condition: Unknown
Due 4 January 1989
Resolved 4 January 1989
Unknown
Issued 5 March 1988
Resolved
IN ACCORDANCE WITH [name withheld], V/P OF AMERICAN GULF I, INC. ALL ITEMSON ATTACHED WORK LIST ARE TO BE COMPLETED IN THE PORT OF NEW ORLEANS, PROBABLY AT ALGIERS IRON WORKS, UPON RETURN FROM PUERTO RICO IN APPROXIMATELY 25-30 DAYS.
Condition: Unknown
Due 5 March 1988
Resolved 5 March 1988
Engineering
Issued 16 December 1987
Resolved
MAKE THREE AIR RECEIVERS IN FOCSLE AVAILABLE FOR INTERNAL EXAM AND OPTEST OF RELIEF VALVES, OR REMOVE SAME FROM VESSEL. IF REMOVED FROM VESSEL, OCMINEW ORLEANS (INSPECTION DEPT) IS TO BE NOTIFIED.
Condition: Unknown
Due 16 December 1987
Resolved 16 December 1987
Construction/Loadline
Issued 16 December 1987
Resolved
REPAINT DRAFT MARKS ON BOW AND STERN AS REQUIRED BY 46 CFR 97.40-10.
Condition: Unknown
Due 16 December 1987
Resolved 16 December 1987
Construction/Loadline
Issued 16 December 1987
Resolved
REPAINT THE DECK LINE AND THE LOAD LINE ON BOTH SIDES OF THE VESSEL AS REQUIRED BY 46 CFR 97.40-15
Condition: Unknown
Due 16 December 1987
Resolved 16 December 1987
Engineering
Issued 29 May 1987
Resolved
COMPLY WITH THE PROVISIONS OF 33 CFR 151 AND 155/MARPOL 73/78 PROVIDE [name withheld] TO MEET EQUIVALENTS FOR ISSUANCE OF AN IOPP CERTIFICATE
Condition: Unknown
Due 29 May 1987
Resolved 29 May 1987
Electrical
Issued 29 May 1987
Resolved
MAKE REPAIRS TO THE FORWARD STARBOARD SIDE POWER DISTRUBUTION POWER PANEL.
Condition: Unknown
Due 29 May 1987
Resolved 29 May 1987
Engineering
Issued 29 May 1987
Resolved
REPLACE THE RUBBER FLOATIBLE HOSE ON THE BILGE PUMP PIPING AT THE PUMP WITHAN APPROVED TYPE.
Condition: Unknown
Due 29 May 1987
Resolved 29 May 1987
Electrical
Issued 29 May 1987
Resolved
RENEW GLOBES AND GUARDS THROUGHOUT THE VESSEL AS NECESSARY PRIOR TO LOADING CARGO.
Condition: Unknown
Due 29 May 1987
Resolved 29 May 1987
Engineering
Issued 29 May 1987
Resolved
REPLACE FUEL HOSES ON THE GENERATOR WITH APPROVED TYPE.
Condition: Unknown
Due 29 May 1987
Resolved 29 May 1987
Construction/Loadline
Issued 10 March 1987
Resolved
PROCEED TO NEAREST REPAIR FACILITY TO INSPECT AND MAKE PERMANENT REPAIRS TO HOLE IN PORT SIDE IN WAY OF NO. 2 BALLAST TANK. BARGE MAY BE OFFLOADED,BUT NO ADDITIONAL CARGO IS TO BE LOADED. COMPLIANCE DATE IS 17MAR87.
Condition: Unknown
Due 10 March 1987
Resolved 10 March 1987
Documentation
Issued 11 December 1985
Resolved
PROVIDE THE AS BUILT PLANS TO MMT NEW ORLEANS FOR APPROVAL: ELECTRICAL DETAILS HYDRAULICS COMPRESSED AIR
Condition: Unknown
Due 11 December 1985
Resolved 11 December 1985
Construction/Loadline
Issued 11 December 1985
Resolved
PROVIDE ACCESS TO ALL VOIDS BY REMOVING THE WELDED COVERS AND REPLACING THEM WITH BOLTED TYPE MANHOLE COVERS.
Condition: Unknown
Due 11 December 1985
Resolved 11 December 1985
Documentation
Issued 11 December 1985
Resolved
PROVIDE A VALID MARINE DOCUMENT.
Condition: Unknown
Due 11 December 1985
Resolved 11 December 1985
Construction/Loadline
Issued 11 December 1985
Resolved
CONDUCT AN AIR TEST OF THE FORE PEAK TANK IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 11 December 1985
Resolved 11 December 1985