PROTEUS

PROTEUS is a 2011 offshore supply vessel. The Coast Guard has recorded 27 inspections since 2010, most recently in April 2026, along with 15 deficiencies and 5 casualty investigations between 2011 and 2023.

Records from 2010 to 2026. Most recent: inspection, 15 April 2026.

Built
2011
Last inspected
15 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9617686 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDQ6041
1054599
Flag
UNITED STATES
367474360
Maury page id
psix-1054599

Inspections, by type

…with no type recorded8
Years with a record 14 calendar years (2010–2026)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)178.6 ft × 46.0 ft × 15.0 ft
Registered tonnagegross 472 / net 321
ITC dimensions (L × B × D)178.6 ft × 46.0 ft × 15.0 ft
ITC tonnagegross 1,272 / net 381
BuilderMASTER BOAT BUILDERS INC · CODEN, AL, UNITED STATES · built 2011
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 2 September 2025 · expires 30 September 2026
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it381 - Convention (Subpart B), Net Ton
321 - Regulatory (Subpart C or D), Net Ton
1009 - Dead Weight, Gross Ton
1272 - Convention (Subpart B), Gross Ton
472 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ6041MMSI 367474360 · active · compulsorily equipped · granted 16 September 2025, expires 16 September 2035
WDF6447MMSI 367474360 · cancelled · compulsorily equipped · granted 6 October 2020, cancelled 9 September 2025
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

DOUG Freight Ship · MISLE 991933 · 10 August 2011 · activity 4111469

Inspection history · 27

15 April 2026 Vessel Attendance · Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8332318
25 February 2026 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8316757
3 April 2025 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8104446
29 May 2024 Deficiency Check · Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7922740
26 April 2023 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7675868
28 March 2023 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7668623
23 February 2023 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7640941
26 October 2022 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7590848
14 June 2022 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7476958
25 February 2021 Drydock Exam · Internal Structural Exam · Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7146577
13 October 2020 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7075916
11 October 2020 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7078482
8 September 2020 Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7053105
7 September 2020 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7075696
10 February 2020 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6906505
4 February 2019 Internal Structural Exam · Drydock Exam · Administrative Inspection · Periodic Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6620545
15 August 2018 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6532929
19 July 2018 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6505071
25 January 2018 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6343817
18 September 2017 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6276058
6 February 2017 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6083594
29 January 2016 Internal Structural Exam · Hull Examination · COI Inspection · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5807839
16 May 2012 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4313014
10 August 2011 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4111469
10 August 2011 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4112068
10 December 2010 Plan Review (Other than "T")
Administrative · USCG Heartland District (dp) · USCG Heartland District (CGD-H) · Activity 4375801
26 March 2010 Initial Certification · Inclining Experiment · Construction Oversight · Plan Review (Other than "T") · MTSA Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3703356

Deficiency record · 15

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 April 2026 Resolved
Nontank vessels subject to this subpart may not operate upon the navigable waters of the United States unless in compliance with a vessel response plan (VRP) approved under § 155.5065. Vessel shall have an VRP approval letter onboard.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2026
Resolved 27 April 2026
Resolution: Received confirmation of VRP placed onboard.
01 - Certificates & Documentation › 013 - Documents › SOPEP
Issued 15 April 2026 Resolved
No manned ship subject to this part may operate unless it carries on board a shipboard oil pollution emergency plan approved by the Coast Guard. Vessel shall have a SOPEP approval letter onboard.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2026
Resolved 27 April 2026
Resolution: Received confirmation that SOPEP was placed onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 May 2024 Resolved
Operating generators must provide a continuous and uninterrupted source of power for the ship's service load under normal operational conditions. When testing the remote fan shutdowns for the engine room, the #2 generator shut down and dropped the load from the main switchboard causing a temporary blackout. 46 CFR 111.10-4(d)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2024
Resolution: UPS now working properly. Verified proper labeling of emergency shutdowns for fuel oil and lube oil pumps/seperator. The UPS charger is now added to panel L-6 as a seperate breaker. Previously it was wired in to the remote shut downs for the engine room.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 29 May 2024 Resolved
Each OSV must have posters or signs displayed in the vicinity of each survival craft and the survival craft's launching controls that— illustrate the procedures for operating the launching device. The liferaft launching instructions posted do not accurately depict the launching procedures to be followed in an emergency. If followed, the painter would not be secured, allowing the liferaft to be deployed without inflating the rafts. 46 CFR 133.90(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 June 2024
Resolution: Life raft stowage has been changed to allow releasing of the straps holding the life rafts in place without loosing access to the painter in accordance with launching diagram.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 29 May 2024 Resolved
Lighting for survival craft launching, including muster stations, embarkation stations, the survival craft, its launching appliances and the area of the water where it is to be launch must be energized from the final emergency power source. The embarkation stations listed on the fire and safety plan did not contain emergency lighting for embarkation of the vessel's liferafts. 46 CFR 129.110(b) 46 CFR Table112.05-5(a) 46 CFR 112.15-1(g)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 June 2024
Resolution: The embarkation areas on the main deck now have emergency lighting.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 29 May 2024 Resolved
If a vessel is to be constructed, altered, or repaired, the plans, information, and calculations required by this part must be submitted to the OCMI in the zone where the vessel is to be altered or the the Marine Safety Center. The vessel has a portable accommodations module (PAM) installed on the back deck of the vessel as defined in CG-ENG Policy Letter No. 01-16 paragraph 5.a.i. The PAM on board has not been certified in accordance with this policy. Correct deficiency prior to use of this portable accommodation. 46 CFR 127.120
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 June 2024
Resolution: The Portable Accommodation Module (PAM) containing the AUV has been removed. Discussion was had on how to add a PAM in the future. We also discussed the history of this AUV and ways to move forward.
01 - Certificates & Documentation › 013 - Documents › Fire control plan - all
Issued 29 May 2024 Resolved
Each applicant for approval of plans and for an original Certificate of Inspection shall submit three copies of the following: Safety Plan (Fire-Control Plan), for OCMI review and approval. The Fire Control Plan onboard was unsigned with hand written modifications and requires Coast Guard approval. 46 CFR 127.110 (a)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 June 2024
Resolution: New fire control plan walked by MI and new plan stamped.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 29 May 2024 Resolved
Each penetration of a bulkhead in a machinery space by piping must meet the design requirements for material and pressure in subchapter F of this chapter. Non-metallic piping penetrating the aft engine room bulkhead did not have a valve on either side of the bulkhead to make the bulkhead watertight. 46 CFR 174.195(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 June 2024
Resolution: The non-metallic piping was removed from the bulkhead and capped off. The crew also installed a metallic pipe with a cap on one side in case anyone were to install that non-metallic pipe in the future.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 29 May 2024 Resolved
Hatchway coamings fitted with weathertight hatch covers of steel or other equivalent material fitted with gaskets and clamping devices shall be as specified in § 42.15-25(a)(1). The engine room escape hatch was holed in way of the dog pocket on the forward side. 46 CFR 42.15-30(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 June 2024
Resolution: Hole in engine room escape hatch repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 29 May 2024 Resolved
Scuppers and discharge pipes originating at any level and penetrating the shell either more than 171/2 inches below the freeboard deck or less than 231/2 inches above the summer load waterline shall be provided with a nonreturn valve at the shell. The non return valve in way of the side shell for the water making system is leaking. 46 CFR 42.15-60(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 June 2024
Resolution: Non-return valve replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 September 2020 Resolved
Vessel experienced a propulsion casualty resulting in the shutdown of the vessel's Port Engine. Additional concern has been raised regarding water intrusion from a leaking keel cooler. Vessel is required to assess damage and repair to the satisfaction of the attending marine inspector prior to movement.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 10 September 2020
Resolved 17 September 2020
Resolution: Vessel entered drydock and affected necessary repairs to damaged prop and keel cooler.
Stability › Watertight Integrity › General
Issued 25 January 2018 Resolved
On the STBD midship escape hatch, the gasket had a large gap and the stop for the hatch 'dog' was broken, not allowing the hatch to be secured. Replace the gasket and reweld the stops.
Action required: 705 - Other - as specified
Due 1 February 2018
Resolved 29 January 2018
Resolution: Vessel representative sent pictures of completed work.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 18 February 2011 Resolved
The means of securing stern anchors in the stowed position stowed position has had no plan review. Provide and test to the satisfaction of the attending marine inspector in Morgan City, LA. 46 CFR 127.210
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 7 March 2011
Resolution: Attended vsl and cleared deficiency to the satisfaction of the attending Coast Guard Marine Inspector.
Engineering › Pressure Vessel › Pressure Gauge
Issued 18 February 2011 Resolved
PVHO'S are out of hydro, relief valves not tested. Complete prior to being placed into service to the satisfaction of the attending marine inspector. PVHO's will need to be added to pressure vsl list in MISLE. 46 CFR 197.328, 46 CFR 197.332 & MSM VOL 2 C1-7
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 7 March 2011
Resolution: Attended vsl and cleared deficiency to the satisfaction of the attending Coast Guard Marine Inspector.
Construction/Loadline › Structures › Air Pipe
Issued 18 February 2011 Resolved
Dive air /mixed gas system tubing system incomplete and will need to be tested. Installed tubing and cylinders certifications/installation have been verified and inspected. 46 CFR 197.462
Action required: 705 - Other - as specified
Resolved 7 March 2011
Resolution: Attended vsl and cleared deficiency to the satisfaction of the attending Coast Gaurd Marine Inspector.

Casualty record · 5

10 August 2011Routine · role: Involved in a Marine Casualty · activity 4111469
7 September 2020Routine · role: Involved in a Marine Casualty · activity 7075696
11 October 2020Routine · role: Involved in a Marine Casualty · activity 7078482
26 October 2022Routine · role: Involved in a Marine Casualty · activity 7590848
28 March 2023Routine · role: Involved in a Marine Casualty · activity 7668623
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

OCEAN PROJECT (2011–2023). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.