Records from 2016 to 2025. Most recent: inspection, 13 June 2025.
Inspection history · 27
13 June 2025
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8158797
4 October 2023
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7801998
22 June 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7484340
27 March 2022
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7419249
24 March 2022
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7416352
22 March 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7416573
2 March 2022
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7404727
22 December 2021
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7371407
22 December 2021
Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7371532
21 September 2021
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7317057
3 July 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7243209
29 June 2021
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7239102
15 April 2021
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7175981
7 January 2021
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7120871
15 October 2020
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7077601
6 August 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7025719
2 August 2020
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7023945
13 February 2020
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6900922
6 February 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6904243
6 February 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6910657
27 March 2017
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6107996
27 January 2017
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6079509
23 January 2017
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6075152
18 July 2016
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5953636
18 June 2016
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5959731
16 May 2016
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5878478
12 March 2016
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5828667
10 - Safety of Navigation › N/A - No Subsystem › Pilot ladders and hoist/pilot transfer arrangements
Issued 24 March 2022
Resolved
All pilot ladders used for pilot transfer shall be clearly identified with tags or other permanent marking so as to enable identification of each appliance for the purpose of inspection. PSCO noted the starboard side pilot ladder did not have an identification plate or markings.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 27 March 2022
Resolution: Sector New Orleans received required class documents. Deficiency cleared.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 April 2021
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs; fire detection and fire alarm systems... smoke detector in oil purifier room was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 April 2021
Resolved 17 April 2021
Resolution: Received class report confirming repairs.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 15 April 2021
Resolved
Surfaces with temperatures above 220 degrees C which may be impinged as a result of a fuel system failure shall be properly insulated... pipe lagging in the oil purifier room allowed significant pipe steam to escape, bypassing proper insulation.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 16 April 2021
Resolved 15 April 2021
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 18 June 2016
Resolved
1410 - The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. Vessel's class report attests to faulty injector on No.4 cylinder. 74SOLAS(14)II-1/26.1
Action required: 17 - Rectify deficiencies prior to departure
Due 18 July 2016
Resolved 18 July 2016
Resolution: Class report attests to repair and safe operation.