Records from 2014 to 2024. Most recent: operational control imposed, 22 August 2024.
Documentation record
Registered dimensions (L × B × D)61.5 ft × 20.9 ft × 4.6 ft
Registered tonnagegross 14 / net 9
ITC dimensions (L × B × D)61.5 ft × 20.9 ft × 4.6 ft
ITC tonnageNot recorded
BuilderMARIONETTE MARINE · MARIONETTE, WI, UNITED STATES · built 1985
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMOUNTAIN VILLAGE, AK
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 3 October 2025 · expires 30 November 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Regulatory (Subpart C or D), Gross Ton
9 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 August 2024
Resolved
All portable fire extinguishers, semi-portable fire extinguishers and fire detection systems must be inspected or tested at least once every 12 months IAW NFPA 10 by a licensed fire extinguisher servicing agency. Inspector observed the fire fighting equipment listed above has not been inspected since 2018. USCG inspector wrote up same deficiency last year and company did not rectify after 01 year passed. 46CFR142.240
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 September 2025
Resolved 11 September 2025
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 22 August 2024
Resolved
Vessel needs to meet COI manning requirements. The COI requires 01 captain and 01 licensed mate. Inspector observed there was no licensed mate operating the vessel. Upon further inspection, Inspector observed the vessel has been operating without a licensed mate since last year, even when the vessel is operating for more than 12 hours.
46CFR15.515
46CFR15.805(a)(5)
46CFR 15.810(b)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 30 September 2025
Resolved 11 September 2025
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 August 2024
Resolved
A towing vessel must carry 3 day and 3 night visual distress signals. This requirement can be met by 06 handheld red flares w/approval code 160.636 or 160.136. Inspector observed only 04 hand held red flares. Vessel needs either 02 more or 02 day distress signals. 46CFR136.200
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 September 2025
Resolved 11 September 2025
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 22 August 2024
Resolved
Operating restrictions or direction necessary for the vessel's master or watch to ensure stability of vessel must be documented in clear and concise manner and maintained onboard the vessel. Inspector observed no stability letter or other instructions onboard while the vessel was operating. 46CFR140.605
Action required: 17 - Rectify deficiencies prior to departure
Due 30 September 2025
Resolved 11 September 2025
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 22 August 2024
Resolved
A towing vessel must carry adequate and up to date charts and maps. Inspector observed no paper charts and an electronic chart system that was not u to date and did not show the correct land features. The other did not show where the navigable channel was. 46CFR140.705
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 September 2025
Resolved 11 September 2025
11 - Life Saving Appliances › N/A - No Subsystem › Anti-exposure suits
Issued 22 August 2024
Resolved
Each immersion suit must have a life jacket light securely attached to shoulder area of immersion suit. Inspector observed no such light on immersion suits. 46CFR141.350
46CFR199.70(c)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 October 2025
Resolved 11 September 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 August 2024
Resolved
The water light must be secured around the body of the life buoy. MI observed 02 water lights that were not secured on body of lifering, but on lanyard instead. 46CFR141.360
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 October 2025
Resolved 11 September 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 August 2024
Resolved
The following items need to be recorded in official logbook: personnel records, safety orientation. MI observed the aforementioned items were not logged. 46CFR146.915
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 October 2025
Resolved 11 September 2025
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 22 August 2024
Resolved
The EPIRB is required to be stowed in float free bracket w/controls set for automatic activation. MI observed hydro-static release was expired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 October 2025
Resolved 11 September 2025
14 - Pollution Prevention › N/A - No Subsystem › VGP: General
Issued 22 August 2024
Resolved
When operating vessel on boady of water where discharge of sewage is prohibited by EPA, the operator must secure each marine sanitation device in a manner that prevents discharge of sewage. MI observed overboard discharge pipe for sewage was not secured.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2025
Resolved 11 September 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 August 2024
Resolved
A towing vessel must carry original COI onboard vessel and may not operate without COI. Inspector observed COI was not onboard vessel while operating. 46CFR136.200
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 October 2025
Resolved 11 September 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 June 2023
Resolved
Inspections and testing of all portable and semi-portable extinguishers must be inspected and tested once every 12 months as required by NFPA 10. Fire extinguishers have not been serviced and 03 gauges indicated were nearly empty. Re-service or replace portable fire extinguishers prior to operating vessel.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 June 2023
Resolved 10 July 2023
Resolution: Recieved photos of all extinguishers installed on vessel with service tags.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 12 June 2023
Resolved
Marine employers must maintain records of chemical test and be available to the Coast Guard upon request. Crew members pre-employment drug test were not available during the inspection. Provide proof testing has been conducted prior to operation.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 June 2023
Resolved 10 July 2023
Resolution: Received records of that pre-employment drug test were conducted 10JUL2023.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 12 June 2023
Resolved
Marine employers must maintain records of chemical test and be available to the Coast Guard upon request. Crew members pre-employment drug test were not available during the inspection. Provide proof testing has been conducted prior to operation.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 June 2023
Resolved 13 July 2023
Resolution: Received photos of 03 AlcoHAWK PT 500 DOT alcohol screening devices onboard vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 12 June 2023
Resolved
EPIRB and liferaft must be mounted in a manner so that it will float free if the vessel sinks. The EPIRB and liferaft were present but not mounted during the inspection.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 June 2023
Resolved 10 July 2023
Resolution: Received photos of liferaft and EPIRB mounted onboard the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 12 June 2023
Resolved
Vessel must have an AIS Class A device onboard and properly installed. Current AIS antenna is broken and a Class B device. Replace AIS device with the approved type.
Action required: 705 - Other - as specified
Due 6 July 2023
Resolved 11 September 2025
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 12 June 2023
Resolved
Prior to getting underway for the first time each crew member must receive a safety orientation and be recorded. Provide safety orientation records after crew has reported and trained.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2023
Resolved 13 July 2023
Resolution: Recieved copies of vessel familiarization and drills conducted.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 12 June 2023
Resolved
Portable fire pump must be self-priming with a minimum capacity of 80 gallons per minute and not less than 60 pounds per square inch(PSI) at the discharge of the hose. The fire pump onboard is not self-priming.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2023
Resolved 11 September 2025
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 June 2023
Resolved
The fire detection system instillation must be certified by a professional engineer with experience in fire-detection systems or by a NICET level IV fire alarm engineering technician. Certificate and inspection documentation was not available during the inspection. Provide evidence the instillation has been certified or obtain a new inspection and certification.
Action required: 705 - Other - as specified
Due 22 July 2023
Resolved 11 September 2025
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 June 2023
Resolved
Bilge alarms must be audible and visible at the operating station. Alarms did not work, but were corrected during the inspection.
Action required: 10 - Deficiency Rectified
Due 22 June 2023
Resolved 22 June 2023
Resolution: Corrected during the inspection