Inspection history · 24
12 February 2026
Damage Survey · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8307017
26 January 2026
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8301597
6 November 2025
Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8237676
16 October 2025
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8237675
8 January 2025
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8025810
8 January 2024
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7830756
20 November 2023
Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7822961
20 January 2023
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7619220
15 June 2022
Deficiency Check · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7478787
15 June 2022
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7479708
15 June 2022
In-Service Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7483128
15 April 2022
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7355962
19 November 2021
Annual Inspection · Internal Structural Exam · Deficiency Check · Examination of Repairs · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7354035
19 October 2020
DAPI Audit · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7080344
7 August 2020
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7028921
14 January 2020
Internal Structural Exam · Administrative Inspection · Hull Examination · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6889426
18 June 2019
DAPI Audit · Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6717911
9 March 2018
Administrative Inspection · Annual Inspection · Internal Structural Exam · DAPI Audit · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6659215
12 October 2017
Deficiency Check · Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6294950
23 January 2017
Annual Inspection · Deficiency Check · Internal Structural Exam · DAPI Audit · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6108206
2 August 2016
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5960226
30 March 2016
Damage Survey · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5847982
29 March 2016
Type not recorded
No type recorded · Station Islamorada · USCG Southeast District (CGD-SE) · Activity 5843456
29 March 2016
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5844609
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 26 February 2026
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed.
Vessel must undergo a hull inspection by an attending USCG Marine Inspector prior to operating with passengers.
46 CFR 176.840
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 February 2026
Resolved 27 February 2026
Resolution: Attending MI conducted satisfactory hull/damage survey.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 October 2025
Resolved
A vessel must carry one floating waterlight. Ring buoy waterlight required by COI is missing. Make installation to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2025
Resolved 2 November 2025
Resolution: Vessel installed floating water light to life buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 January 2024
Resolved
46 CFR 180.70(b)(1)
Each ring life buoy on a vessel must: Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150.
MI observed grab line deteriorated rendering the life buoy not serviceable.
Action required: 10 - Deficiency Rectified
Due 8 January 2024
Resolved 8 January 2024
Resolution: Vessel replaced life buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 January 2024
Resolved
46 CFR 180.71(a)
An adult life jacket must be provided for each person carried on board a vessel.
MIs observed 01 adult sized life jacket that was deteriorated rendering it not serviceable.
Action required: 10 - Deficiency Rectified
Due 8 January 2024
Resolved 8 January 2024
Resolution: Vessel replaced life jacket.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 January 2024
Resolved
46 CFR 185.604 (h)
Each life jacket must be marked with Type I retro-reflective material approved in 46 CFR 164.018 or other standard specified by the Commandant.
MI observed 10 adult life jackets that had deteriorated
Type I retro-reflective material.
Action required: 10 - Deficiency Rectified
Due 8 January 2024
Resolved 8 January 2024
Resolution: Vessel replaced retro-reflective material.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 20 January 2023
Resolved
A hatch cover must have securing devices.
MI found a missing dog on the midship deck hatch.
46 CFR 179.360(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2023
Resolved 30 January 2023
Resolution: Owner sent picture of installed dogging device.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 January 2023
Resolved
A vessel not required to have a power driven fire pump must have at least three 2 1/2 gallon buckets with an attached lanyard. The words “FIRE BUCKET” must be stenciled in a contrasting color on each.
MI found one of the three required fire buckets having less than the required 2 1/2 gallon capacity.
46 CFR 181.610
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2023
Resolved 30 January 2023
Resolution: Owner sent photo of new bucket.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 December 2021
Resolved
First aid kit had expired items. Must replace expired items.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2022
Resolved 15 December 2021
Resolution: Replaced all expired items.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 December 2021
Resolved
Life ring grab line was dry rotted. Must replace grab line
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2022
Resolved 15 December 2021
Resolution: Bought new line and replaced, all SAT
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 December 2021
Resolved
Retro tape on 1 adult life jacket needs replacing. Must replace with SOLAS retro tape.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2022
Resolved 15 December 2021
Resolution: Replaced all Retro tape on all jackets except one, bought new life jacket. All SAT
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 December 2021
Resolved
1 of the 3 required fire buckets were only 2 gallons instead of the 2 1/2 gallon required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2022
Resolved 15 December 2021
Resolution: Replaced fire bucket.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 October 2020
Resolved
Retro on most life jackets were worn and needed replacing. Vessel has roll of retro but with current weather, un able to attach. Replace all retro.
46 CFR 180.71
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2020
Resolved 6 December 2021
Resolution: Verified all life jackets had new SOLAS retro tape.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 20 October 2020
Resolved
Vessel did not have correct Nav chart on board. Replace with correct NOAA approved Nav Chart.
46 CFR 184.420
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2020
Resolved 6 December 2021
Resolution: Updated GPS to meet requirements of NVIC 01-16
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 20 October 2020
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2020
Resolved 6 December 2021
Resolution: Ned no longer works for company
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 20 October 2020
Resolved
Vessel not logging fire and MOB drills properly. Start logging drills as required in 46 CFR 185.520 and 185.524
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2020
Resolved 6 December 2021
Resolution: Started new log book and logging as required.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 20 October 2020
Resolved
Vessel has no logs for training of new hire personal or quarterly training as required. Start new log for training as required in 46 CFR 185.420
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2020
Resolved 6 December 2021
Resolution: Vessel showed proof of crew training.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 20 October 2020
Resolved
Un able to conduct drills due to severe weather and small craft advisory. Must conduct drills within the next 30 days.
46 CFR 185.524
46 CFR 185.520
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 November 2020
Resolved 6 December 2021
Resolution: Vessel underway to conduct MOB and fire drills.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 June 2019
Resolved
Hardware on tow post is loose and broken. Renew
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 June 2019
Resolution: Replaced all hardware with new stainless steel bolts. Verified, all SAT.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 June 2019
Resolved
Engine room high level alarm is inoperable. Repair/renew
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 June 2019
Resolution: Cleaned contacts on switch, and rewired to fuse pannel. Verified, all SAT.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 18 June 2019
Resolved
Renew/repair VHF, Input MMSI# and GPS signal.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 June 2019
Resolution: Purchased new radio with built-in GPS transeiver, and installed MMSI#. Verified, all SAT.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 June 2019
Resolved
Bilge visual auto alarm is inoperable. Repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 July 2019
Resolution: Bilge auto visual alarm was repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 June 2019
Resolved
Raw water supply valve handle is broken. Renew/repair
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 July 2019
Resolution: A new raw water supply valve handle was purchased and replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 June 2019
Resolved
Fire equipment must have an annual inspection. Provide.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 July 2019
Resolution: Annual inspection was conducted on all fire equipment on board.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 18 June 2019
Resolved
Provide up to date chart or chartlet.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 July 2019
Resolution: Up to date chart was provided.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 18 June 2019
Resolved
Engine room vent covers are missing. Provide.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 July 2019
Resolution: Engine room vent covers were located and installed.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 9 March 2018
Resolved
Vessel does not have valid COD.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2018
Resolution: New COD was provided.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 9 March 2018
Resolved
FWD Bilge high level alarrm is inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2018
Resolution: Alarm was repaired and tested.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 9 March 2018
Resolved
Engine Room high level alarm is inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2018
Resolution: Alarm was repaired and tested.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 9 March 2018
Resolved
EPIRRB Hydrostatic release is expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 March 2018
Resolution: Hydrostatic release was renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Means of recovery of life saving appliances
Issued 9 March 2018
Resolved
life ring grabline is wasted.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 March 2018
Resolution: New life ring was provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 March 2018
Resolved
Lifejackets need new reflective material.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 March 2018
Resolution: All lifejackets were repaired or renewed.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 23 January 2017
Resolved
COD is expired and must be renewed prior to any operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 January 2017
Resolution: Owner received proof of new documentation.
Communications › Radio Communications › EPIRB
Issued 23 January 2017
Resolved
EPIRB battery has expired and must be repair or renewed prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 January 2017
Resolution: Owner purchased a new EPIRB.
Documentation › Certificates/Documents › FCC SSL
Issued 23 January 2017
Resolved
FCC station license is expired.
Action required: 705 - Other - as specified
Due 6 February 2017
Resolved 6 February 2017
Resolution: NEw FCC station license was provided.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 23 January 2017
Resolved
FCC safety radiotelephoney certificate is expired.
Action required: 705 - Other - as specified
Due 6 February 2017
Resolved 6 February 2017
Resolution: New FCC safety radio cert was provided.
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 23 January 2017
Resolved
FCC radio operator license is not available.
Action required: 705 - Other - as specified
Due 6 February 2017
Resolved 6 February 2017
Resolution: License was provided and will be kept with the Capt license.
Lifesaving › Hand Flares › Storage
Issued 23 January 2017
Resolved
Flares are not in a brightly colored box.
Action required: 705 - Other - as specified
Due 6 February 2017
Resolved 6 February 2017
Resolution: New orange waterproof box properly marked was provided.
Documentation › Logs/Records › Logbook (official)
Issued 23 January 2017
Resolved
Vessel does not have a log for EPIRB testing and safety gear maint.
Action required: 705 - Other - as specified
Due 6 February 2017
Resolved 6 February 2017
Resolution: New logs were created and will be maintained.
Navigation › Piloting/Steering › Marine Charts
Issued 23 January 2017
Resolved
Charts and publications are not up to date. Provide updated charts and publications.
Action required: 705 - Other - as specified
Due 6 February 2017
Resolved 6 February 2017
Resolution: New charts and publications were provided.