Records from 2016 to 2026. Most recent: inspection, 9 July 2026.
Inspection history · 46
9 July 2026
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8447885
20 February 2026
ACP COI Oversight · Re-Inspection
Physical examination · Activities Europe · Activity 8313180
18 February 2026
ACP Drydock Oversight
Administrative · Activities Europe · Activity 8311957
1 May 2025
ACP Annual Oversight · Annual Inspection
Physical examination · Activities Europe · Activity 8126427
1 April 2024
ACP Annual Oversight · Annual Inspection
Physical examination · Activities Europe · Activity 7887897
10 January 2023
ACP Annual Oversight · Annual Inspection
Physical examination · Activities Europe · Activity 7622127
6 December 2022
Administrative Inspection
Administrative · Activities Europe · Activity 7605420
16 September 2022
Administrative Inspection
Administrative · Activities Europe · Activity 7560138
18 July 2022
Administrative Inspection
Administrative · Activities Europe · Activity 7509730
7 December 2021
Annual Inspection · ACP Annual Oversight · Administrative Inspection
Physical examination · Activities Europe · Activity 7354022
16 November 2021
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7351737
18 June 2021
Administrative Inspection
Administrative · Activities Europe · Activity 7228864
13 April 2021
Administrative Inspection
Administrative · Activities Europe · Activity 7174352
26 February 2021
Administrative Inspection
Administrative · Activities Europe · Activity 7146787
16 December 2020
Administrative Inspection
Administrative · Activities Europe · Activity 7112655
29 October 2020
Administrative Inspection · Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7086232
28 October 2020
Administrative Inspection
Administrative · Activities Europe · Activity 7085638
24 June 2020
Administrative Inspection
Administrative · Activities Europe · Activity 6985565
11 June 2020
Deficiency Check
Physical examination · Activities Europe · Activity 6973761
27 May 2020
Administrative Inspection
Administrative · Activities Europe · Activity 6961486
28 January 2020
Deficiency Check · Annual Inspection
Physical examination · Activities Europe · Activity 6897578
24 November 2019
Type not recorded
No type recorded · Activities Europe · Activity 6866969
5 November 2019
Drydock Exam · Deficiency Check
Physical examination · Activities Europe · Activity 6849317
29 May 2019
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6698733
22 May 2019
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6692517
13 May 2019
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6683117
2 May 2019
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6675005
19 March 2019
Internal Structural Exam · In-Service Inspection · Periodic Inspection · ISM SMC Audit · Plan Review (Other than "T") · Drydock Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6644962
15 January 2019
Administrative Inspection · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6610847
7 January 2019
Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6591185
2 November 2018
Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6573384
20 August 2018
Damage Survey
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6517706
10 August 2018
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6619765
6 July 2018
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6469105
5 April 2018
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6386411
8 March 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6370945
7 March 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6370459
6 February 2018
Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6350705
16 March 2017
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6106236
4 January 2017
Annual Inspection · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6065850
18 October 2016
Excursion Permit
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6025004
23 August 2016
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5981258
29 July 2016
Administrative Inspection · Construction Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5956512
17 June 2016
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5910530
6 June 2016
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5898838
8 April 2016
Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5850193
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › UMS - Ship
Issued 20 February 2026
Resolved
Measures shall be taken to the satisfaction of the Administration to ensure that the equipment is functioning in a reliable manner and that satisfactory arrangements are made for regular inspections and routine tests to ensure continuous reliable operation. PMS system required emergency fuel shutoff valves (Quick Closing Valves) testing at 99 year intervals. MSC.1/Circ.1432 requires testing at least annually. Update PMS interval.
SOLAS 74am (24ConsEd)
II-1/46.2 &
II-2/4.2.2.3.4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2026
Resolved 1 April 2026
Resolution: ABS SC issued.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 20 February 2026
Resolved
Oil fuel pipes, which, if damaged, would allow oil to escape from a storage, settling or daily service tank having a capacity of 500l and above situated above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire occurring in the space in which such tanks are situated. Remote fuel shut-off valve cables broke on Gens 3 & 4 during testing. Repaired by crew and tested satisfactory.
SOLAS 74am (24ConsEd)
II-2/4.2.2.3.4
Action required: 10 - Deficiency Rectified
Resolved 21 March 2026
Resolution: Cables repaired and retested before completion of COI
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 February 2026
Resolved
No electrical equipment shall be installed in paint lockers, unless the Administration is satisfied that such equipment is essential for operational purposes;
of a type which will not ignite the mixture concerned;
appropriate to the space concerned; and appropriately certified for safe usage in the dusts, vapours or gases likely to be encountered. PA wiring conduit in paint store is broken exposing cables and conduit has electrical tape in a few other spots. Explosion prrof light at door missing bolt. Also, SFP was removed/damaged in two locations during shipyard period. Repairs completed.
SOLAS 74am (24ConsEd)
II-1/45.10
Action required: 10 - Deficiency Rectified
Resolved 21 March 2026
Resolution: Repairs comlpleted prior to completion of COI
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 11 May 2025
Resolved
Fire-fighter's outfits shall comply with the FSS Personal equipment shall consist of the following: axe with a handle provided with high-voltage insulation. For each breathing apparatus a fireproof lifeline of at least 30 m in length shall be provided. The fire-fighter's outfits were missing the axes and lifelines. Due 12Aug2025.
Cite: SOLAS II-2/Reg 10.10.2.1; FSS Code 2.1.1.5 and 2.1.3
Action required: 705 - Other - as specified
Due 12 August 2025
Resolved 22 May 2025
Resolution: ABS issued finding
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 11 May 2025
Resolved
The Administration shall be satisfied that adequate arrangements are in place to ensure that the performance of the equipment required by this chapter is maintained. The stbd bridge wing gyro repeater was cracked and no longer watertight. Due 12Aug2025.
Cite: SOLAS (2009) V/Reg 16.1
Action required: 705 - Other - as specified
Due 12 August 2025
Resolved 11 August 2025
Resolution: Class issued finding.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 11 May 2025
Resolved
Doors provided to ensure the watertight integrity of internal openings capable of being remotely closed from the bridge...Indicators are to be provided at the control position showing whether the doors are open or closed. The watertight door (WTD) indication panel on the bridge did not properly illuminate for the aft WTD. Due 12Aug2025.
Cite: SOLAS (2009) II-1/Reg 13-1.2
Action required: 705 - Other - as specified
Due 12 August 2025
Resolved 11 August 2025
Resolution: Class issued finding.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 11 May 2025
Resolved
The company should ensure that each ship is manned with qualified, certificated and medically-fit seafarers in accordance with the national and international requirements. During review of the crew’s medical certificates, identified a crewmember that was on board without the waiver outlined by the medical certificate. In addition, the crewmember had been on board for two months and the medical officer was unable provide a copy of the medical certificate waiver. Upon review of the vessel’s SMS, the company is required to provide the medical waivers upon assignment of crewmembers to vessel via email or fax. Conduct an internal audit of the SMS focused on ensuring crew assigned to the vessel are medically-fit. Provide results of internal audit to USCG ACTEUR for review. ABS to verify procedure at next external audit. Due 12Aug2025.
Cite: SOLAS (2009) IX/Reg 3.1; ISM Code Part A 6.2.1
Action required: 705 - Other - as specified
Due 12 August 2025
Resolved 5 October 2025
Resolution: Vessel master provided ISM audit report conducted by ABS with verification of procedure.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 April 2024
Resolved
Storage of gas bottles shall be located on the open deck or in a well-ventilated space which opens only to the open deck. Oxygen and acetylene bottles were being stored in the engineer's workshop. Temporary solution was to move them on deck secured to a storm rail on a pallet. Make a permanent stowage space IAW regulation to the satisfaction of the RO.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2024
Resolved 25 April 2024
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 17 April 2024
Resolved
The condition of the ship and its equipment shall be maintained shall be maintained to conform with the provisions of the present convention to ensure the ship in all respects will remain fit to proceed to sea without presenting an unreasonable threat of harm to the marine environment. OWS would not demonstrate effluent of less than 15ppm going overboard. Make repairs and prove proper operation to the satisfaction of the RO.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2024
Resolved 25 April 2024
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 17 April 2024
Resolved
Means of communication shall be provided between the navigation bridge and the steering compartment. Phone between the steering gear and the bridge were inoperable. Make permanent repairs to the satisfaction of the RO.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2024
Resolved 25 April 2024
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 11 January 2023
Resolved
The angular position of the rudder shall, if the main steering gear is power-operated, be indicated on the navigation bridge. Angle indicator readings differed from the actual readings verified in the steering gear room by 15 degrees.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2023
Resolved 28 January 2023
Resolution: Received finding number from ABS Surveyor.
10 - Safety of Navigation › N/A - No Subsystem › Voyage data recorder (VDR)/Simplified Voyage data recorder(S-VDR)
Issued 10 January 2023
Resolved
To assist in casualty investigations, ships, when engaged on international voyages, subject to the provisions of regulation 1.4, shall be fitted with a Voyage Data Recorder. Vessel's VDR alarm panel showed a 6044 fault for connection with the vsls gyrocompass. Solas Ch.V/Reg. 20.
Action required: 10 - Deficiency Rectified
Due 11 January 2023
Resolved 11 January 2023
Resolution: Vessel had McKay tech out for radar maintenance who ID'd the issue as a short circuit. Made repairs and all working as intended.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 10 January 2023
Resolved
The ring, lines, and letters shall be painted in white or yellow on a dark ground... the marks shall be plainly visible. Load line markings were significantly faded and not distinguishable as a contrasting color.
Action required: 10 - Deficiency Rectified
Due 11 January 2023
Resolved 11 January 2023
Resolution: Vsl painted load line markings white to contrast on dark background.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 10 January 2023
Resolved
Cargo ships shall carroy one or more totally enclosed lifeboats complying with the requirements of section 4.6 of the code... Both lifeboats had expired (by manufacture tag) radar reflectors. Provide radar reflectors as part of lifeboat inventory. SOLAS III reg 31.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 January 2023
Resolved 10 January 2023
Resolution: Vessel provided radar reflectors.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 10 January 2023
Resolved
During preparation and launching of survival craft, adequate illumination of area and embarkation must be provided by an emergency source of power. The port side embarkation lighting was in operable. Provide emergency lighting. SOLAS III reg 16.7
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 January 2023
Resolved 10 January 2023
Resolution: Vessel renewed bulb, test satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 January 2023
Resolved
The machinery and associated piping systems and fittings shall be of a design and construction adequate for the service and installed to a minimum danger to the persons on board. The bolted flange on the discharge side of the L/O transfer pump was leaking L/O. Secure flange in a fashion as to remove the leak. SOLAS II-1 reg 26.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 January 2023
Resolved 10 January 2023
Resolution: Flange was tested/adjusted and proved absent of leaks.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 10 January 2023
Resolved
The company shall comply with the requirements of the International Safety Management Code. The Lock Out Tag Out log on board the vessel had errors and was not in compliance with their approved procedures. Correct the log and maintain in a fashion that satisfies the approved procedures. SOLAS IX reg 3.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 January 2023
Resolved 10 January 2023
Resolution: Policy was reviewed/re-enforced. Logs were corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 10 January 2023
Resolved
Cylinders must always be secured and, when not in use, they must be stowed in a rack in an upright position. R-134a refridgeration cylinders were being stored losely under a ladderwell in the machinery space. Stow the cylinders in a safe manner. 46 CFR 147.60(b).
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 January 2023
Resolved 10 January 2023
Resolution: Cylinders relocated to a safe location. Stored properly.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 January 2023
Resolved
Doors in fire-resisting divisions in cargo ships shall be equivalent to that of the division in which they are installed. They must maintain a self closure as per design. The doors to stair towers 3-73-1, 01-66-1, and 02-72-1 were not closing properly. Adjust to ensure compliance. SOLAS II-2 reg 9.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 January 2023
Resolved 10 January 2023
Resolution: Doors were adjusted to ensure proper closure.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 January 2023
Resolved
Doors in fire-resisting divisions in cargo ships designed for self-closing shall not be fitted with hold-back hooks. The main door into the galley area (class A) was secured open with a make ship hook/rope. Remove hold back. SOLAS II-2 reg 9.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 January 2023
Resolved 10 January 2023
Resolution: Hold back removed and proved self-closing operation as per design.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 January 2023
Resolved
The administration shall take appropriate steps to ensure uniformity in the implementation and application of electrical installations (IEC). Distribution panels P101 and L105 were missing blank covers for removed breakers. Install proper protection. SOLAS II-1 reg 40.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 January 2023
Resolved 10 January 2023
Resolution: Blanks installed, risk of accidental shock was removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 January 2023
Resolved
The administration shall take appropriate steps to ensure uniformity in the implementation and application of electrical installations (IEC). A 110v outlet had been installed in stairtower 1-6601, unsecured and hanging freely by power supply. Cable transition of newly installed outlet was inadequetly secured to prevent spread of heat/smoke. Install outlet and cable transition properly. SOLAS II-1 reg 40
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 January 2023
Resolved 10 January 2023
Resolution: Outlet mounted properly, MCT was renewed with fire stop adhesive.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 31 December 2021
Resolved
General arrangement plans… showing clearly for each deck
the control stations, the various fire sections enclosed
by “A” class divisions, the sections enclosed by “B”
class divisions…The Fire Control Plan categorized the
aft bulkhead for the Library/Conference room, as
category A, the door 1-76-1 is rated as B15, and the
bulkhead cable penetration not fire rated.
SOLAS II-2/15.2.4.1
Action required: 10 - Deficiency Rectified
Due 30 January 2022
Resolved 14 January 2022
Resolution: Accepted by class and provided finding number.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 31 December 2021
Resolved
Posters or signs shall be provided on or in the vicinity
of survival craft and their launching controls and shall
illustrate the purpose of controls and the procedures
for operating the appliance and give relevant
instructions or warnings. Liferaft stations were
outfitted with Zodiac liferafts with Survivtec liferaft
launching directions.
Action required: 10 - Deficiency Rectified
Due 30 January 2022
Resolved 14 January 2022
Resolution: Accepted by class and provided finding number.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 December 2021
Resolved
Lifebuoys…shall be so distributed as to be readily
available on both sides of the ship and as far as
practicable on all open decks extending to the ship's
side; at least one shall be placed in the vicinity of
the stern. Life rings were removed from aft deck/stern.
SOLAS III/Reg 7.1.1.1
Action required: 10 - Deficiency Rectified
Due 30 January 2022
Resolved 14 January 2022
Resolution: Accepted by class and provided finding number.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 31 December 2021
Resolved
Each entrance to a space storing carbon dioxide
cylinders, a space protected by carbon dioxide systems,
or any space into which carbon dioxide might migrate
must be conspicuously marked as follows: CARBON DIOXIDE
GAS CAN CAUSE INJURY OR DEATH. VENTILATE THE AREA BEFORE
ENTERING. A HIGH CONCENTRATION CAN OCCUR IN THIS AREA
AND CAN CAUSE SUFFOCATION.” Steering gear room was
missing signage for CO2 cylinders inside space.
Action required: 10 - Deficiency Rectified
Due 30 January 2022
Resolved 14 January 2022
Resolution: Accepted by class and provided finding number.
05 - Radio Communications › N/A - No Subsystem › Reserve source of energy
Issued 31 December 2021
Resolved
Accumulator batteries shall be suitably housed, and
compartments used primarily for their accommodation
shall be properly constructed and efficiently
ventilated. The GMDSS batteries were located in a
repurposed cabinet on the bridge adjacent from the
GMDSS.
SOLAS II-1/45.9.1
46 CFR 111.15-10,
111.60-17, 111.81-1(c)
COMSAR/Circ. 32
Action required: 10 - Deficiency Rectified
Due 30 January 2022
Resolved 14 January 2022
Resolution: Accepted by class and provided finding number.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 31 December 2021
Resolved
Cables and wiring shall be installed and supported in
such a manner as to avoid chafing or other damage. GMDSS
cables inside the cabinet were found chafed.
SOLAS II-1/45.5.5
Action required: 10 - Deficiency Rectified
Due 31 January 2022
Resolved 14 January 2022
Resolution: Accepted by class and provided finding number.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 December 2021
Resolved
All electrical apparatus shall be so constructed and so
installed as not to cause injury when handled or touched
in the normal manner. In the void space below the
bridge, a junction box cover was missing (stbd side near
piping for antifreeze metering pump) and the wires were
hanging out of the box. In distribution panels, missing
blanks for unused circuit breaker slots.
SOLAS II-1/45.1.3
Action required: 10 - Deficiency Rectified
Due 31 January 2022
Resolved 14 January 2022
Resolution: Accepted by class and provided finding number.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 December 2021
Resolved
Cables and wiring shall be installed and supported in
such a manner as to avoid chafing or other damage. Motor
controllers for lube oil and fuel oil system missing
fittings at bottom of box.
SOLAS II-1/45.5.5
46 CFR 111.81-3
Action required: 10 - Deficiency Rectified
Due 31 January 2022
Resolved 14 January 2022
Resolution: Accepted by class and provided finding number.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 December 2021
Resolved
Oil fuel pipes and their valves and fittings shall be of
steel or other approved material. Valves for drawing
fuel or draining water from fuel are not permitted in
fuel oil systems except that a single valve may be
permitted in the case of diesel driven machinery if
suitably located within the machinery space away from
any potential source of ignition. Such a valve shall be
fitted with a cap or a plug to prevent leakage. Fuel
filters on main diesel engines are missing caps for
drain plugs.
SOLAS II-2/4.2.2.5.1
46 CFR 56.50-75(a)
46 CFR 56.50-60(f)
Action required: 10 - Deficiency Rectified
Due 31 January 2022
Resolved 14 January 2022
Resolution: Accepted by class and provided finding number.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 31 December 2021
Resolved
During transfer operations, each drain and scupper is
closed by the mechanical means required by 33 CFR
155.310. Mechanical plugs were missing from containment.
33 CFR 156.120(o)
Action required: 10 - Deficiency Rectified
Due 31 January 2022
Resolved 14 January 2022
Resolution: Accepted by class and provided finding number.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 31 December 2021
Resolved
The warning statement was missing at the bottom of the
maneuvering characteristics fact sheet in the
wheelhouse.
33 CFR 164.35 (g)(7)
Action required: 10 - Deficiency Rectified
Due 31 January 2022
Resolved 14 January 2022
Resolution: Accepted by class and provided finding number.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 February 2020
Resolved
Wires must be located within enclosures. In the stbd side overhead of the steering compartment there is a danger tag on a 440 volt dead ended wire that was tagged out in November of 2018.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2020
Resolved 27 February 2020
Resolution: Statement from master [name withheld], that a J-box was installed and wires terminate inside for future use.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 February 2020
Resolved
The integrity of any deck in way of a stairway opening shall be maintained by "A" Class doors at every level. The majority of self closing "A" Class fire doors inspected failed to completely close when tested.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2020
Resolved 27 February 2020
Resolution: Statement from master [name withheld], that all doors have been adjusted properly
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 3 February 2020
Resolved
Each fireman's outfit must consist of one fire axe, the axe provided shall be designed with high-voltage insulation.
FSS Code Chapter 3.2.1.1.5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2020
Resolved 27 February 2020
Resolution: Per statement of the master [name withheld], there are 2 suits on board that meet the requirements of 46CFR96.35.10 as well as FSS Code 3.2.1.1.5. Additional gear is required by the owner, US Navy, and acceptable under the MSC/USCG MOA.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 February 2020
Resolved
Oil level gages may be used in place of sounding pipes provided that a failure of such gages does not permit the release of fuel/oil into the space. Steering hydraulic tank sight glasses are gaged with zip ties.
Action required: 10 - Deficiency Rectified
Due 2 March 2020
Resolved 10 February 2020
Resolution: CE removed the gagged zip ties from the sight glasses prior to the departure of the attending MI's.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 February 2020
Resolved
Tests must be conducted at periodic intervals specified by the Coast Guard. The published PSTP's related to the azipod and steering system do not reflect current tests in use by the crew.
Action required: 705 - Other - as specified
Due 2 March 2020
Resolved 18 June 2021
Resolution: PTSPs accepted under ACP entry.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 3 February 2020
Resolved
Reach rods tested in the High Density Survey room for seawater supply failed to operate correctly as the reach rod is no longer retained by installed brackets.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 March 2020
Resolved 10 February 2020
Resolution: Reach rods were reattached to the bulkhead and tested prior to the departure of the attending MI's.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 3 February 2020
Resolved
Rudder angle indicator between the bridge and the steering control station has a deviation of 4-6% and needs to be calibrated to reflect actual position.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2020
Resolved 5 June 2020
Resolution: Email from Master stating item corrected.
10 - Safety of Navigation › N/A - No Subsystem › Communication-SOLAS chap. 5
Issued 3 February 2020
Resolved
Each voice communication station device in the weather must be in a proper enclosure as required in 46 CFR. Junction box C-7JV-010A aft of the bunker station is in a poor state or repair.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2020
Resolved 25 March 2020
Resolution: Based upon email statement from Master, [name withheld].
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 3 February 2020
Resolved
Light fixture located in the emergency generator space is hanging open.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2020
Resolved 27 February 2020
Resolution: Statement from master [name withheld], that housing has been screwed back together.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 3 February 2020
Resolved
Means shall be provided for closing all other openings to the space protected from outside such space. Automatic closure devices for the ventilation for the engine room are not all functioning. Attending MI noted that 25% of the automatic closure devices didn't operated when tested.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 February 2020
Resolved 6 February 2020
Resolution: Received statement from the CE and Master attesting to corrected closure devices.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 3 February 2020
Resolved
When galley vent closures were tested they failed to close. This was first identified in November 2018. The company should establish procedures to ensure the ship is maintained. In the meeting these requirements the company should ensure that any non conformity is reported, and corrective action is taken. ISM Code 10.2.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2020
Resolved 29 April 2020
Resolution: Master sent email and pictures, attesting to the correction, and proper op testing of the deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 May 2019
Resolved
Correctly install electrical bulkhead penetrations at the following locations or prove materials used and current installation meets Regulations:
03 penetrations at stair tower 1-130-2
01 @ WTD1 Door Status indicator at stair tower main deck
01 @ E Generator space.
Penetrations in "A" class bulkheads shall be tested IAW the FTP Code. Penetrations around vessel correctly installed with RoxBlox, those above found with red caulking style fire stop.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2019
Resolved 23 December 2019
Resolution: ABS certified that during attendance, verified the penetrations in "A" class bulkheads were properly installed by maker and tested without remarks. Please see attached ABS report.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 May 2019
Resolved
Remove dead end wires found throughout vessel. Properly terminate dead end wires when not in use. Crew states these wires are used by DOD personnel for various missions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2019
Resolved 19 September 2019
Resolution: Received signed statement from Chief Engineer on board. All roll-on/roll-off mission cables have been properly terminated in junction boxes on both ends and labelled or completely removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 May 2019
Resolved
Any newly installed electrical systems shall undergo plan review from an approved source (USCG-MSC or ABS). Prove installation associated with above wiring penetrations/dead-end wires are on approved plans.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2019
Resolved 19 September 2019
Resolution: Received original plan review and load analysis from shipyard and confirmation that any additional mission cables/equipment utilize pre-existing electrical connections accounted for as spares.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 April 2019
Resolved
All automatically or remotely controlled or monitored vital systems addressed by part 62 of this subchapter must be subjected to tests and inspections to evaluate the operation and reliability of controls, alarms, safety features, and interlocks. Test procedures must be submitted to the Coast Guard for approval.(b) Persons designated by the owner of the vessel shall conduct all tests and the Design Verification and Periodic Safety tests shall be witnessed by the Coast Guard.(c) Design Verification and Periodic Safety test procedure documents approved by the Coast Guard must be retained aboard the vessel. Vessel found with DVTP's which had not been tested by the USCG or the vessels representatives nor approved by the Marine Safety Center prior to the vessel entering service. Vessel shall conduct gap analysis of DVTP revision B and D; any affected tests will need to be witnessed by the USCG.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2019
Resolved 23 May 2019
Resolution: Witnessed satisfactory completion of all DVTPs identified in the DVTP gas analysis required by Sector San Francisco (MISLE Activity 6644962).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 April 2019
Resolved
a) Periodic Safety tests must demonstrate the proper operation of the primary and alternate controls, alarms, power sources, transfer override arrangements,interlocks, and safety controls. a) Periodic Safety tests must demonstrate the proper operation of the primary and alternate controls, alarms, power sources, transfer override arrangements,interlocks, and safety controls.46 CFR 61.40-6
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2019
Resolved 18 June 2021
Resolution: PTSPs accepted as part of ACP entry.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 19 April 2019
Resolved
An emergency diesel generator must have an audible alarm that sounds on low oil pressure and high cooling water temperature. EDG audible alarms can not be heard by watch stander when the alarm is triggered. 46CFR112.50 (h)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2019
Resolved 23 May 2019
Resolution: Witnessed satisfactory operation of the EDG's high J/W temperature and low l/o pressure audible and visual alarm in the ECR.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 April 2019
Resolved
(a) All automatically or remotely controlled or monitored vital systems addressed by part 62 of this subchapter must be subjected to tests and inspections to evaluate the operation and reliability of controls, alarms, safety features, and interlocks. Test procedures must be submitted to the Coast Guard for approval.(b) Persons designated by the owner of the vessel shall conduct all tests and the Design Verification and Periodic Safety tests shall be witnessed by the Coast Guard.(c) Design Verification and Periodic Safety test procedure documents approved by the Coast Guard must be retained aboard the vessel. Vessel found with DVTP's which had not been tested by the USCG or the vessels representatives nor approved by the Marine Safety Center prior to the vessel entering service. Vessel shall conduct all DVTP tests in the presence of a CG Marine Inspector and submit to MSC for approval.
Condition: Improper Installation
Action required: 30 - Ship detained
Resolved 18 April 2019
Resolution: Revision D was not found signed off by the [name withheld] downgraded to 50 C to require a Gap analysis between revisions to determine DVTP's not completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 April 2019
Resolved
(a) Periodic Safety tests must demonstrate the proper operation of the primary and alternate controls, alarms, power sources, transfer override arrangements,interlocks, and safety controls. Systems addressed must include fire detection and extinguishing, flooding safety, propulsion, maneuvering, electric power generation and distribution, and emergency internal communications.(b) Tests must be conducted at periodic intervals specified by the Coast Guard to confirm that vital systems and safety features continue to operate in a safe, reliable manner. Note: Normally, these tests are conducted annually. Vessel found with PSTP Rev. H on board, however no records of testing were available. During selected tests equipment operated contrary to stated test requirements with several required tests missing from the procedures. Crew did not have necessary testing equipment on board. Vessel shall demonstrate required PSTP's and submit all necessary revisions to the MSC.
Condition: Improper Installation
Action required: 30 - Ship detained
Resolved 18 April 2019
Resolution: Completed all PSTP testing that could be completed pierside. PSTP's updated to include Reverse Power Relay tests, Low L/O shutdown for EDG, and High J/W temp alarm for EDG. Updated PSTP's need to be submitted to MSC for approval.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 April 2019
Resolved
The prime mover of an emergency generator must shut down automatically upon loss of lubricating oil pressure. Vessels Emergency Diesel Generator did not shut down upon loss of L/O pressure. Generator had never been programed to shut down for this failure as required. Vessel contracted repairs during the inspection.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 12 April 2019
Resolution: Repair technician provided to reprogram EDG to shutdown upon loss of lube oil as required.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 April 2019
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. The following functional requirements shall be met. Means shall be provided to limit the accumulation of flammable vapours. Vessel found with inoperable ventilation for the paint locker in April of 2018, crew ordered replacement vent fan which was subsequently canceled by the company. Vent fan was rebuilt during the March 2019 dry-dock but never reinstalled. Inoperable fan allowed enclosed space with hazardous ship stores to accumulate dangerous vapors & fumes which posed hazard to crew health and presented increased danger of fire and explosion. Vessel shall reinstall vent fan.
Action required: 30 - Ship detained
Resolved 15 April 2019
Resolution: Ventilation Fan for Paint Locker Repaired, installed, and is in operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 April 2019
Resolved
Means shall be provided where by normal operation of propulsion machinery can be sustained or restored even though one of the essential auxiliaries becomes inoperative. Special consideration shall be given to the malfunction of a generating set which serves as a main source of electrical power, source of lube oil pressure, source of water pressure, or hydraulic/pneumatic/electrical means for control in main propulsion machinery. Vessel does not have “Ships Allowance List” specific to the ships equipment to ensure parts are obtainable through procurement procedures. There is an unknown amount of critical spares aboard, however multiple identified critical pumps, pump components, breakers, contactors, and fuses were not aboard due to them faltering in the procurement process due to lack of the “Ships Allowance List”. Vessel shall create a ship specific "ships allowance list" in order to ensure compliance with 74SOLAS(cons) Reg. II-1/26.3. Proof shall be provided that adequate spare parts have been provided aboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2019
Resolved 7 January 2020
Resolution: ABS attested to parts being ordered and provided documentation as such. Please see documents.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 12 April 2019
Resolved
Per ISM Code Part A 3.3.3, The Company is responsible for ensuring that adequate resources and shore based support are provided to enable the designated person or persons to carry out their functions. Vessel found with 200 outstanding acquisition items which included multiple critical spares for vital machinery and various vital electrical components. Multiple requests were noted as canceled without alternative methods of corrective action taken. Records were provided detailing excessive wait times for equipment required by applicable rules and regulations including mooring lines and azimuth circles which took 8 months to procure. Company’s failure to provide needed parts in a reasonable amount of time has been noted as a great hindrance to the crew's ability to safely operate and maintain the ships equipment. Vessel shall ensure an external SMS audit is conducted focusing on the provision of requested parts to the vessel and the lack of ship specific “Ships Allowance List”.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 April 2019
Resolved 2 May 2019
Resolution: External Audit conducted in Sector San Diego. Copy of findings, responses, and corrective actions received.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 11 April 2019
Resolved
All enclosed spaces within the vessel shall be properly vented or ventilated. Means shall be provided to close off all vents and ventilators. Boatswain Storeroom (1-16-1) vent damper has a 1” gap on both sides when in the closed position. Bow Thruster Room (1-15-2) vent damper has 2” gap when in the closed position. Both dampers do not adequately secure the flow of air when closed. Affect repairs to dampers and demonstrate full closure to attending CG marine inspector.
46 CFR 190.15-10(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2019
Resolved 22 May 2019
Resolution: Witnessed satisfactory operation of both fire dampers.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 11 April 2019
Resolved
The position of the rudder, if power operated, must be shown at the principal steering station. If there is non-follow-up steering control at the alternative steering station, there must be a separate rudder angle indicator system for that station. Port bridge wing rudder angle indicator is unreadable due to condition of plastic cover that is screwed in over the panel. Replace or remove plastic cover from panel.
46 CFR 113-40-5
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2019
Resolved 2 May 2019
Resolution: Plastic cover was cleaned and RAI is visible.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 April 2019
Resolved
The integrity of a stairtower shall be maintained by ‘A’ class doors at every level. The door shall be of the self closing type. Stairtower door (3-65-1) on 01 deck listed as self closing ‘A’ door on fire control plan did not fully close. Additionally, the following self closing ‘A’ doors did not close; Dry Lab on main deck, [name withheld]/Crew Lounge on 01 deck, Fan Room on 01 deck, Galley Door (01-85-1). The following two self closing ‘A’ doors were found with broken closing arms; Trash Disposal room on 01 Deck and Fan Room (1-24-2) on main deck. Demonstrate proper self closing operation of all doors listed above.
46 CFR 190.07-10d(d)(4)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2019
Resolved 19 April 2019
Resolution: Trash Disposal Room on 01 Deck and Fan Room 1-24-2 demonstrated properly closed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 April 2019
Resolved
Electric installations on vessels must ensure: Protection of passengers, crew, other persons, and the vessel from electrical hazards. Several dead end wires were present in the chart room on the bridge, located near the ECDIS processor panel. Remove or properly cap dead end wires.
46 CFR 111.01-1(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2019
Resolved 2 May 2019
Resolution: Wires were capped and stowed.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 4 April 2019
Resolved
The general construction of the vessel shall be such as to minimize fire hazards. Library/Conference Room on main deck has 02 doors that fire control plan state are self closing, however, they are not. Install self closing devices on doors.
46 CFR 190.05-3
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2019
Resolved 4 December 2019
Resolution: See letter submitted by CHENG attesting to fix.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 7 January 2019
Resolved
Rapid recovery of the rescue boat must be possible when loaded with its full complement of persons and equipment. If the rescue boat is also a lifeboat, rapid recovery must be possible when loaded with its lifeboat equipment and an approved rescue boat complement of at least six persons. Rescue boat can only be recovered by hand cranking the winch.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 January 2019
Resolution: Replaced proximity switch. Demonstrated proper operation of davit.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 7 January 2019
Resolved
There are no accesses to examine fire dampers in the accommodations to verify proper operation. Provide access/inspection port and prove proper operation of fire dampers.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2019
Resolved 19 April 2019
Resolution: Access covers provided for fire dampers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 January 2019
Resolved
Periodic safety test must demonstrate the proper operation and alternate controls, alarms, power sources, transfer over ride arrangements, interlocks, and safety controls. Vessel did not have tech/equipment needed to conduct tests. Prove proper operation of all emergency and automatic shut downs, reverse power relays, over speed devices, etc..., on all main engines/generators.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2019
Resolved 19 April 2019
Resolution: All equipment and techs provided to demonstrate proper operation of all emergency and automatic shutdowns,reverse power relays, and overspeed devices on all main engines/generators.New def entered to have PSTP's updated to include missing test procedures.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 7 January 2019
Resolved
No person may operate an ocean going ship of 400 gross tons and above unless it is fitted with approved 15 parts per million oily-water separating equipment for the processing of oily mixtures from bilges or fuel oil tank ballast. Crew was not able to demonstrate the use of the OWS. Not able to activate 3-way valve, oil content meter or alarm for OWS. Prove proper operation of OWS and alarms.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2019
Resolved 16 April 2019
Resolution: Verified proper operation of OWS.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 7 January 2019
Resolved
A device must process human sewage in the manner for which it is designed. Sensor that controls the automation for vessels sewage holding tank is inoperable. Renew sensor and prove proper operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2019
Resolved 17 April 2019
Resolution: Received technical repair report from Green Marine. Green Marine Service tech attended vessel on 3/13/2019 and inspected and tuned sensor/sludge solenoid that was not operable. Witnessed all proper operation of testing and alarms.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 7 January 2019
Resolved
Each Class 3 watertight door must have controls in accordance with ASTM 1197, An audible alarm, distinct from any other alarm in the area, shall give warning whenever the door is closed remotely by power and shall sound for at least 5 seconds, but no more than 10 seconds, prior to door movement for Class 3 doors. Consideration should be given to supplementing the audible alarm with a visual alarm in high noise areas. Indicators for Class 3 watertight doors were inop. Prove proper operation of indicators.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2019
Resolved 10 April 2019
Resolution: Witnessed proper operation of Class 3 watertight doors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 January 2019
Resolved
Systems exposed to pressures higher than system MAWP shall be safeguarded. Test relief valves on air receiver
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 February 2019
Resolved 16 April 2019
Resolution: Tested relief valve on service air receiver. Relief valve popped at 138 PSI.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 6 July 2018
Resolved
Starboard side life boat falls were damaged while attempting to recover life boat at sea. Falls required to be replaced and weight test conducted in presence of CG MI prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 July 2018
Resolved 11 July 2018
Resolution: Witnessed weight test on new wire fall. Cleared deficiency.
Engineering › Electric Propulsion System › Reverse Power Protection Relay Circuitry
Issued 6 February 2018
Resolved
Demonstrate proper operation of reverse power relay during parallel operations.
Action required: 705 - Other - as specified
Due 7 March 2018
Resolved 9 February 2018
Resolution: Witnessed proper operation of the reverse power relay IAW the Military Sealift Commands written procedures.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 6 February 2018
Resolved
Provide vessel with necessary equipment to carry out Periodic Safety Test Procedures.
Action required: 705 - Other - as specified
Due 7 March 2018
Resolved 8 March 2018
Resolution: Received copy of a packing slip showing that the necessary equipment to carry out the PSTPs had been provided to the crew.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 6 February 2018
Resolved
Amend Periodic Safety Test Procedures to include testing of Reverse Power Relay. Obtain approval from Marine Safety Center prior to obtaining reduced manning associated with unmanned machinery space.
Action required: 705 - Other - as specified
Resolved 12 April 2019
Resolution: Conducted test of reversepower relays for all 4 MDG's. PSTP's are to be updated to include test procedure.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 6 February 2018
Resolved
Update SOLAS Training manuals and maintenance procedures for lifeboats to include installed onload/offload releasing mechanism.
Action required: 705 - Other - as specified
Due 12 February 2018
Resolved 9 February 2018
Resolution: The SOLAS training manual was updated to reflect the new equipment.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Valves
Issued 6 February 2018
Resolved
Make repairs or replace high ressure water mist valve (in water mist pump room) that is leaking by and causing nozzle to drip from machinery space nozzles.
Action required: 705 - Other - as specified
Due 7 March 2018
Resolved 8 March 2018
Resolution: Valve was replaced.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 17 January 2017
Resolved
Vessel does not have an approved Periodic Safety Test Procedure. Additionally, the procedure currently submitted to MSC for approval does not accurately specify the test procedures to be followed. Vessel shall review the procedure for accuracy and conduct a test prior to requesting attendance of a Marine Inspector to verify satisfactory resolution.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 January 2017
Resolved 10 February 2017
Resolution: All PSTP items satisfactoriy tested.
Engineering › Thrusters › Motor
Issued 6 June 2016
Resolved
STBD Z-Drive lost propulsion power. The steering is still operational. The vessel is to complete repairs in Port Everglades, FL. Repairs to the STBD Z-Drive are to be made to the satisfaction of the attending Marine Inspector.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 17 June 2016
Resolution: Vessel replaced the control module in the Thruster Cabinet and conducted satisfactory dockside trilas with ABS and CG Inspectors in attendance
Lifesaving › Lifeboat › Seating
Issued 28 April 2016
Resolved
Verify lifeboats have proper seating and labeling for 67 persons.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 May 2016
Resolved 8 June 2016
Resolution: Seating verified.
Lifesaving › Lifeboat › Markings
Issued 28 April 2016
Resolved
Provide correct data plate installed on lifeboats by manufacturer that meet CFR requirements.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 May 2016
Resolved 8 June 2016
Resolution: Verified required data plate information installed on lifeboats.