Records from 1990 to 2009. Most recent: inspection, 4 March 2009.
Inspection history · 24
4 March 2009
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3427341
20 April 2005
Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2410288
15 December 2004
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2259962
5 March 2004
Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2018942
28 January 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1995467
4 December 2002
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1714493
30 January 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1482554
29 September 2000
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 823263
28 September 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 161425
23 August 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1429405
18 August 1999
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1421722
13 August 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1402699
20 August 1997
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1446527
22 August 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1424272
22 August 1995
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1371147
26 August 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1407363
26 August 1993
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1385118
17 May 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1463049
25 June 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 673184
12 June 1992
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1354167
20 May 1992
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1419033
25 April 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 915286
19 April 1991
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1236794
18 May 1990
Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 923157
Communications › Alarms/Indicators
Issued 28 January 2004
Resolved
Provide bilge alarms for all watertight compartments. LEGACY COMPONENT DESC: Bilge Alarm
Action required: 705 - Other - as specified
Due 28 February 2004
Resolved 23 April 2004
Documentation › Certificates/Documents
Issued 28 January 2004
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 28 February 2004
Resolved 5 February 2004
Lifesaving › Lifejacket/PFD (Type I)
Issued 28 January 2004
Resolved
Renew Retro reflective Tape on 05 PFD's. LEGACY COMPONENT DESC: Retro reflective Material
Action required: 17 - Rectify deficiencies prior to departure
Due 28 February 2004
Resolved 29 January 2004
Lifesaving › Lifebuoys
Issued 28 January 2004
Resolved
Renew name and retro reflective tape on life ring. LEGACY COMPONENT DESC: Markings (ship name/port)
Action required: 17 - Rectify deficiencies prior to departure
Due 28 February 2004
Resolved 29 January 2004
Fire Fighting › Miscellaneous Items
Issued 28 January 2004
Resolved
Provide 03 fire buckets. LEGACY COMPONENT DESC: Fire Buckets
Action required: 17 - Rectify deficiencies prior to departure
Due 28 February 2004
Resolved 29 January 2004
Lifesaving › Buoyant Apparatus
Issued 4 December 2002
Resolved
Repair or replace 2 ea life floats, restowe in float free arrangement.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2002
Resolution: Floats reworked by approved vendor.
Construction/Loadline › Hull › Longitudinal Frame
Issued 4 December 2002
Resolved
Reweld as original longitudinal frame in forepeak.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2002
Resolution: Frame rewelded by shipyard.
Engineering › Fuel Oil Service System › Filter
Issued 30 January 2002
Resolved
Replace Raycor flame shield on Port Engine.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2002
Resolved 30 January 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 30 January 2002
Resolved
Install Fixed Fire Extinguishing system in Engine Room. LEGACY COMPONENT DESC: Tanks
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 December 2002
Resolved 23 April 2004
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 30 January 2002
Resolved
Service Portable Fire Extinguishers at fire station #2 and #3. LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2002
Resolved 23 April 2004
Fire Fighting › Ventilation Systems
Issued 30 January 2002
Resolved
Provide vent closures for engine room. LEGACY COMPONENT DESC: Duct Hatches
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2002
Resolved 23 April 2004
Lifesaving › Lifejacket/PFD (Type I)
Issued 30 January 2002
Resolved
Stencil Lifejackets with vsl name. LEGACY COMPONENT DESC: Marking
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2002
Resolved 23 April 2004
Electrical › Lighting (service)
Issued 30 January 2002
Resolved
Replace burned out anchor light. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2002
Resolved 23 April 2004
Lifesaving
Issued 20 August 1997
Resolved
REPLACE/REPAIR MISSING/DAMAGED RETRO-REFLECTIVE TAPE ON LIFE RING.
Condition: Unknown
Due 27 August 1997
Resolved 22 August 1997
Lifesaving
Issued 20 August 1997
Resolved
REPLACE 03 UNSERVICABLE LIFE JACKETS 22 ONBOARD 25 REQUIRED. REDUCED TOTALPERSON ALLOWED FROM 25 TO 22.
Condition: Unknown
Due 27 August 1997
Resolved 20 August 1997
Accommodation/Occupational Safety
Issued 20 May 1992
Resolved
REPLACE BROKEN WINDOW IN PASSENGER AREA STBD SIDE
Condition: Unknown
Due 20 June 1992
Resolved 12 June 1992
Construction/Loadline
Issued 20 May 1992
Resolved
PAINT HAILING PORT ON STERN
Condition: Unknown
Due 20 June 1992
Resolved 12 June 1992
Fire Fighting
Issued 20 May 1992
Resolved
PROVIDE ONE ADDITIONAL B-II FIRE EXTINGUISHER
Condition: Unknown
Due 20 June 1992
Resolved 12 June 1992
Fire Fighting
Issued 20 May 1992
Resolved
PROVIDE HAND FIRE PUMP
Condition: Unknown
Due 20 June 1992
Resolved 12 June 1992