MAURY USCG vessel records
← All vessels

PRIDE OF CASSVILLE

Built
2011
Last inspected
3 April 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 3 April 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 16 calendar years (2011–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1062675
Flag
UNITED STATES
Maury page id
psix-1062675

Documentation record

Registered dimensions (L × B × D)74.8 ft × 32.0 ft × 5.0 ft
Registered tonnagegross 98 / net 98
ITC dimensions (L × B × D)74.8 ft × 32.0 ft × 5.0 ft
ITC tonnagegross 98 / net 98
BuilderSKIPPER MANUFACTURING LLC · LACROSSE, WI, UNITED STATES · built 2011
Hull materialSteel
PropulsionNone
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORT OF CASSVILLE, WI
Endorsements, as the file codes themcw_un
DocumentationValid · issued 9 July 2025 · expires 31 August 2026
Service, as the file records itPassenger Barge (Inspected)
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Convention (Subpart B), Gross Ton
98 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 31 inspections, each with its date, unit and type; 35 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

PRIDE OF CASSVILLE Towing Vessel · MISLE 1144091 · 11 August 2011 · activity 4145372

Inspection history · 31

3 April 2026 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8341465
2 December 2025 In-Service Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 8277516
22 October 2025 Internal Structural Exam · Administrative Inspection · Drydock Exam · Hull Examination
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8257836
20 May 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8141600
12 June 2024 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7933727
21 August 2023 Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7826011
1 June 2023 Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7703483
17 May 2022 Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7453365
5 May 2021 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7193878
28 October 2020 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7087061
24 August 2020 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7026379
28 May 2019 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6706516
1 June 2018 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6433657
26 June 2017 Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6187062
18 May 2017 Administrative Inspection · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6149004
6 May 2016 MARPOL Annex V Examination · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5870448
26 February 2016 Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5822882
13 October 2015 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5743066
24 June 2015 Spot Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5163233
11 May 2015 DAPI Audit · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5126187
31 July 2014 DAPI Audit · Annual Inspection · MARPOL Annex VI Survey
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4943409
21 November 2013 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4757447
13 November 2013 Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4751739
5 October 2012 Deficiency Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4458132
13 June 2012 DAPI Audit · Deficiency Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4344107
26 April 2012 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4296656
23 August 2011 Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4124757
12 August 2011 Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4113249
12 August 2011 Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4113270
11 August 2011 Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4145372
11 July 2011 Initial Certification · Deficiency Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4098712

Deficiency record · 35

18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 3 April 2026 Resolved
An Employee Assistance Program (EAP) training program must be conducted for the employer's crewmembers and supervisory personnel...Supervisory personnel must receive at least 60 minutes of training. Employer was unable to provide evidence of supervisory EAP training. 46 CFR 16.401(b)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2026
Resolved 20 May 2026
Resolution: Employeer provided course info and stated employees are to complete
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 22 October 2025 Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. MI observed deteriorate bilge strainer in Void 1. 46 CFR 182.510(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 October 2025
Resolved 30 October 2025
Resolution: Operator provide photo of replaced strainer.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 12 June 2024 Resolved
The vessel's lifesaving / abandon ship crew harness's lifeline did not have adequate length or was able to be adequately secured to the vessel during the man overboard drill. Replace lifeline to a satisfactory length to allow crewmembers to safely recovery a person in the water. Provide objective evidence of replacement to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2024
Resolved 30 July 2024
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 12 June 2024 Resolved
Vessel did not have or provide passengers with verbal or visual safety orientation prior to disembarking on short ferry ride. Provide verbal safety orientation or visual signage attached to the vessel's bulkhead and/gunnels. Provide objective evidence to the satisfaction of the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2024
Resolved 30 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 1 June 2023 Resolved
Ring Buoys are required to be marked with Type II retro-reflective material per IMO Resolution A.658(16). The retro-reflective tape on 02 ring buoys was deteriorated. Replace retro-reflective tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 23 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 June 2023 Resolved
Vessel is required to have 02 fixed power pumps for the bilge. One of the pumps was not operational. Repair or replace pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2023
Resolved 20 July 2023
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 1 June 2023 Resolved
Fire pump must have a means to intake water underway. Current system using the PVC pipe does not hold up to the current and forces while in motion. Replace with an adequate means for water intake.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2023
Resolved 23 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 June 2023 Resolved
Vessel must have required amount of adult life jackets on board the vessel at all times. 01 Adult life jacket was missing. Add 01 additional life jacket and re-label the container it is placed in with the new quantity. Vessel limited to 148 passengers.
Action required: 705 - Other - as specified
Resolved 23 June 2023
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 1 June 2023 Resolved
Crew members must have a safe means to bring an incapacitated passenger on board. Provide a system and properly train all crew in how to utilize the system safely.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2023
Resolved 23 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 August 2020 Resolved
Label ring buoy mounted near ITV with vessel name.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2020
Resolved 4 September 2020
Resolution: Vessel rep sent photos of ring buoys freshly labeled with vessel name.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 August 2020 Resolved
Replace Type II retroreflective tape on ring buoy mounted near ITV.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2020
Resolved 4 September 2020
Resolution: Vessel rep sents photos of all ring buoys with new retro tape.
09 - Working and Living Conditions › 092 - Working Conditions › Personal equipment
Issued 24 August 2020 Resolved
Provide on board a first aid kit that meets approval series 160.041.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2020
Resolved 4 September 2020
Resolution: Vessel rep sent photos of replaced first aid equipment with valid expiration dates.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 19 May 2017 Resolved
Provide safety harness for man overboard evolution/recovery at rescue platform.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 19 June 2017
Resolved 19 June 2017
Resolution: Provided evidence of Harness
Electrical › Electrical Distribution System (service) › Junction Box
Issued 11 May 2015 Resolved
Each connection to a conductor must be made within an enclosure, Void 2 and void 3 has AC wire that is spliced and outside of an enclosure. Must be spliced inside an enclosure. 46CFR183.340 (G) due 11JUN15
Action required: 705 - Other - as specified
Due 26 June 2015
Resolved 19 June 2015
Resolution: Sent pictures, Sat.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 May 2015 Resolved
Vessel's Aspirin, ammonia inhalants and iodine swabs are expired and or missing and does not meet minimum standard quantity of 100 tablets of aspirin (can be in plastic vials of 20), (10) 1/2 ml iodine swab type and 10 ammonia inhalants as required by 46CFR184.710 and 46CFR160.041 . Owner must renew contents. Vessel has 30 days to correct deficiency. Due 11JUN15.
Action required: 705 - Other - as specified
Due 11 June 2015
Resolved 26 May 2015
Resolution: Vessel''s Aspirin, ammonia inhalants and iodine swabs have been renewed
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 11 May 2015 Resolved
Vessels MIS report was not filled out and submitted by 15MAR15 and does not meet the minimum requirements as required by 46CFR16.500. Owner must submit MIS report. Due 11JUN15.
Action required: 705 - Other - as specified
Due 11 June 2015
Resolved 21 May 2015
Resolution: Vessels MIS report was filled out and submitted
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 5 October 2012 Resolved
Properly secure life jacket storage conatiner to the deck for handicap accessibility 46CFR180
Action required: 705 - Other - as specified
Due 9 June 2013
Resolved 3 June 2013
Resolution: Owner secured life jjacket storage container.
Documentation › Logs/Records › Drug Test Records
Issued 13 June 2012 Resolved
Prove compliance for statistically based random drug testing.
Action required: 705 - Other - as specified
Resolved 18 July 2012
Resolution: Proved compliance for statistically based random drug testing.
Documentation › Logs/Records › Drug Test Records
Issued 13 June 2012 Resolved
Prove consortium enrollment
Action required: 705 - Other - as specified
Resolved 6 July 2012
Resolution: Proved consortium enrollment
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 26 April 2012 Resolved
Life jacket containers not secured to deck causing a safety hazard. Secure to prevent movement.46CFR180
Action required: 705 - Other - as specified
Resolved 5 October 2012
Resolution: Life jacket containers are secured to the handrails, one remaining to be secured on the deck for handicap accessibility will write new CG-835 for that requirement, 46CFR180
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 26 April 2012 Resolved
Portable fire exinguishers not inspected annually as required. 46CFR181.500.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2012
Resolution: Portable fire exinguishers have been inspected annually as required. 46CFR181.500.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 April 2012 Resolved
First Aid Kit found in poor condition with expired contents. Replace with approved First Aid Kit as per regs. 46CFR184.710 and 46CFR160.041
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2012
Resolution: Replaced with approved First Aid Kit as per regs. 46CFR184.710 and 46CFR160.041
Engineering › Bilge Water Management System › Piping
Issued 26 April 2012 Resolved
Bilge Piping on vessel may not be PVC material. Replace portions of piping with metalic piping. 46CFR182.710.
Due 26 July 2012
Resolved 13 June 2012
Resolution: Replaced portions of piping with metalic piping. 46CFR182.710.
Engineering › Steering Gear System › Helix Shaft
Issued 12 August 2011 Resolved
Vessel is not allowed to carry passengers or vessels, until the permanent repair is made to the steering system and hydraulic clamping system securing the barge alongside the vessel. Repairs should be to the satisfaction of the OCMI
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 August 2011
Resolved 19 August 2011
Resolution: Permanent repairs have been made to the steering system and hydraulic clamping system securing the barge alongside the vessel.
Engineering › Steering Gear System › Helix Shaft
Issued 12 August 2011 Resolved
Vessel is not allowed to carry passengers or vessels, until the repair is made to the steering system and is to the satisfaction of the OCMI.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 August 2011
Resolved 19 August 2011
Resolution: Vessel is allowed to carry passengers or vessels
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 11 July 2011 Resolved
Stowage containers for life jackets is not secured to vessel and is easily moveable. Stowage containers must be secured to vessel
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 26 April 2012
Resolution: Re-issued Def.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 11 July 2011 Resolved
Line on life buoys is not ready for immediate use. Secure life buoy and attached line in a way that allows for immediate use.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 August 2011
Resolved 30 August 2011
Resolution: Line on life buoys are ready for immediate use. Secured life buoy and attached line in a way that allows for immediate use
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 July 2011 Resolved
First Aid kit must be on board vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2011
Resolved 30 August 2011
Resolution: First Aid kit is on board vessel.
Personnel › Training › Fire Fighting Basic
Issued 11 July 2011 Resolved
Passenger safety orientation as required by 46CFR185.506 must be given at each voyage to the passengers
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 August 2011
Resolved 15 October 2015
Resolution: Passenger safety orientation as required by 46CFR185.506 is given at each voyage to the passengers
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 11 July 2011 Resolved
Certificate of documenation must be provided to attending inspector
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2011
Resolved 30 August 2011
Resolution: Certificate of documenation has been provided to attending inspector
Documentation › Certificates/Documents › Stability Letter
Issued 11 July 2011 Resolved
Stability letter must be provided to attending inspector
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2011
Resolved 30 August 2011
Resolution: Stability letter was provided to attending inspector
Operations/Management › Drills/Instruction › Safety Orientation
Issued 11 July 2011 Resolved
Vessel must maintain a count of passengers during voyages
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 August 2011
Resolved 30 August 2011
Resolution: Vessel is maintaining a count of passengers during voyages
Personnel › Training › Personal Safety/Social Responsibilities
Issued 11 July 2011 Resolved
Life jacket donning instructions must be posted for passengers
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2011
Resolved 30 August 2011
Resolution: Life jacket donning instructions was posted for passengers
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 July 2011 Resolved
Vessels towing alongside must display a special yellow navigation light as required by 46CFR 183.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2011
Resolved 30 August 2011
Resolution: Vessel has a temporary special yellow navigation light as required by 46CFR 183.420
Personnel › Training › Familiarization Training
Issued 11 July 2011 Resolved
Emergency operating instructions as required by 46CFR 185.510 must be posted at the operating station
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2011
Resolved 30 August 2011
Resolution: Emergency operating instructions as required by 46CFR 185.510 was posted at the operating station

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.