MAURY USCG vessel records
← All vessels

GLOBAL SEATTLE

Built
2010
Last inspected
7 July 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 7 July 2026
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 17 calendar years (2010–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1062699
Flag
UNITED STATES
Maury page id
psix-1062699

Documentation record

Registered dimensions (L × B × D)182.4 ft × 46.0 ft × 15.0 ft
Registered tonnagegross 1,004 / net 306
ITC dimensions (L × B × D)182.4 ft × 46.0 ft × 15.0 ft
ITC tonnagegross 1,004 / net 306
BuilderTRINITY MARINE PRODUCTS INC PLANT 38 · MADISONVILLE, LA, UNITED STATES · built 2010
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORTLAND, OR
Endorsements, as the file codes themcw_un
DocumentationValid · issued 18 December 2025 · expires 31 January 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1004 - Convention (Subpart B), Gross Ton
306 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 27 inspections, each with its date, unit and type; 17 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 3 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

GRIZZLY Towing Vessel · MISLE 92199 · 17 April 2017 · activity 6176777ALYSSA ANN Towing Vessel · MISLE 88937 · 13 November 2014 · activity 5023596KODIAK Towing Vessel · MISLE 150375 · 13 November 2014 · activity 5023596

Inspection history · 27

7 July 2026 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8431829
22 July 2025 COI Inspection · Cargo Tank Internal
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8193006
19 September 2024 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 8006338
11 September 2023 Periodic Inspection · Internal Structural Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7789372
23 August 2023 In-Service Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7775176
22 February 2023 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7637970
26 September 2022 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7584826
30 September 2021 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7324093
31 January 2021 Examination of Repairs · Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7133725
24 September 2020 COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7064278
23 September 2019 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6815275
11 October 2018 Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6559245
17 October 2017 Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6290295
17 April 2017 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6176777
27 January 2017 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6078575
11 October 2016 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6028855
21 September 2015 COI Inspection · Internal Structural Exam · Hull Examination · MTSA Verification
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5724933
13 November 2014 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5023596
1 November 2014 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5016302
9 October 2014 Annual Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4992731
21 June 2014 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4895112
25 January 2014 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4789175
5 November 2013 Periodic Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4748375
26 October 2013 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4741588
4 December 2012 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4496063
1 November 2011 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4181984
23 July 2010 Internal Structural Exam · Construction Oversight · MTSA Verification · Initial Certification · Drydock Exam · Cargo Tank Internal
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3833169

Deficiency record · 17

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 October 2022 Resolved
All electrical installations in hazardous locations must comply with the general requirements of section 33 of IEEE 45-1998. A battery not contained in an explosion proof container was located on deck inside of a hazardous location. Prove to the satisfaction of attending Marine Inspector compliance with section 33 of IEEE 45-1998 or remove battery from hazardous location, prior to cargo operations.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 28 October 2022
Resolved 28 October 2022
Resolution: Battery was removed from Response vessel and placed inside the FWD house, outside of any hazardous locations.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Risk evaluation, training and instruction to seafarers
Issued 28 October 2022 Resolved
All motors and electrical installations in hazardous locations must comply with the general requirements of section 33 of IEEE 45-1998. Response skiff located in a hazardous location. Place onboard skiff a placard instructing crew not to place battery into service or energize motor while skiff is located within a hazardous location and update crew training to reflect this requirement. Submit evidence to USCG completion of such within 90 days.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 January 2023
Resolved 22 February 2023
Resolution: Training documents updated to reflect not attaching battery while skiff is located in the hazardous zone. A placard has been placed onboard skiff reminding of same.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 28 October 2022 Resolved
A Certificate of Documentation (COD) is not valid unless, “the vessel is marked with the name, official number and hailing port as shown on the certificate” as per the instructions on the certificate. Hailing Port on vessel is Listed as Seattle, WA while COD lists hailing port as Portland, OR. Within 90 days submit evidence to the satisfaction of USCG that Hailing Port permanently marked on vessel and COD match.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 January 2023
Resolved 22 February 2023
Resolution: Vessel Owner submitted application to amend COD to NVDIC. Receipt of application provided to Marine Inspector.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 October 2022 Resolved
A response plan submitted to meet the requirements § 155.1040 must identify the training to be provided to the spill management team, the qualified individual, and other personnel in § 155.1040 with specific responsibilities under the plan including tankermen and members of the towing vessel crew. The training program must differentiate between that training provided to vessel personnel and that training provided to shore-based personnel. (b) A vessel owner or operator shall ensure the maintenance of records sufficient to document this training and make them available for inspection upon request by the Coast Guard. VRP and training records were requested but could not be produced. Vessel to make available for inspection within 90 days VRP and associated training records.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 January 2023
Resolved 3 April 2023
Resolution: Received notification via email with attachment that VRP has been accepted and approved by USCG VRP Office.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 28 October 2022 Resolved
The transfer procedures required by 46CFR155.720 which are mandated to be complied with as specified by 46CFR155.730 require the PIC to log the testing of the overfill devices required by 46CFR155.480 in the daily log book. Evidence of these tests could not be produced. Vessel to initiate logging these tests in accordance w/ the Transfer Procedures or modify the procedures to remove this requirements and ensure the recording of the tests of the overfill devices as identified in 46CFR156.170 are completed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 January 2023
Resolved 22 February 2023
Resolution: Recievied updated cargo transfer procedures. Crew training has been provided and testing is to be logged in HELM.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 28 October 2022 Resolved
All safety and relief valves for use on pressure vessels or piping systems shall be designed to meet the protection and service requirements for which they are intended and shall be set to relieve at a pressure which does not exceed the “maximum allowable working pressure” of the pressure vessel or piping system and marked accordingly. ABS is requiring vessel to de-rate pressure vessel to 99 PSI or replace pressure vessel with ABS approved pressure vessel. Within 90 days notify CG Marine Inspector of action taken and mark pressure vessel IAW regulations.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 January 2023
Resolved 22 February 2023
Resolution: Owner [name withheld] documentation that pressure vessel was derated. Vessel particulars have been updated in this activity to reflect the new MAWP, relief valve settings and test dates.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 January 2021 Resolved
The GLOBAL SEATTLE incurred an inset between frames 17 - 22 of the port side shell. Subsequently, internal damage was caused to the hull framing in way of the #2P cargo tank. Hull and frame structure shall be repaired/renewed to satisfactory condition. Integrity of the cargo envelope for Cargo Tank #2P shall be verified and witnessed by CG MI. The following conditions are limiting on the vessel: 1. Vessel's crew shall monitor the space for water ingress and log findings. 2. Deficiency is to be rectified at first available dry docking. Cargo operations are allowed in the interim with the exception of the #2P tank for no longer than 30 days.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2021
Resolved 9 April 2021
Resolution: Inspected all welds. Pressed up tank tested welds inside Cargo tank #2P and external hull plate welds. All Sat.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 23 September 2019 Resolved
If a vessel collects vapor emitted to or from a vessel cargo tank with a vapor control system (VCS), the system must not be used unless each vapor hose, vapor collection arm, pressure or vacuum relief valve, and pressure sensor is tested and inspected in accordance with paragraphs (b), (c), and (f) of this section. The VCS must be tested annually or as part of a biennial and mid-period inspections. Rectify w/ in 30 days and/or prior to next cargo transfer requiring operation of the vessel's VCS. 33 CFR 156.170(g)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2019
Resolved 4 November 2019
Resolution: GLOBAL SEATTLE VCS equipment test records provided and found all sat.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 23 September 2019 Resolved
Each vessel vapor connection flange face must have a permanent stud projecting outward that has a .5 inch diameter and is at least 1 inch long. Multiple VCS flanges did not have studs. 46 CFR 39.2001(j)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2019
Resolved 4 November 2019
Resolution: 1" studs were installed to each flange of the VCS.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 23 September 2019 Resolved
Cargo pump pressure gauge shall be tested at least once a year for accuracy. The cargo pump pressure gauge was not tested for accuracy within the past year. 46 CFR 35.35-70(c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2019
Resolved 4 November 2019
Resolution: GLOBAL SEATTLE pressure gauge calibration records provided and found all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 October 2018 Resolved
Locate source of diesel fuel oil in cofferdam void underneath machinery space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2018
Resolved 6 November 2018
Resolution: Pneumatic test conducted. No visual indication of leak.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 October 2018 Resolved
Put proper cover on junction box located in aft section of cofferdam void underneath machinery space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 November 2018
Resolved 6 November 2018
Resolution: Received photo with proper cover on junction box.
Operations/Management › Cargo Transfer/Lightering › Use of Vapor Control System
Issued 5 November 2013 Resolved
Vessel does not USCG approved plans for the vapor control system. Provide vapor control system plans or ABS plan approval to the Marine Safety Center for review.
Due 28 November 2013
Resolved 15 November 2013
Resolution: Vessel electronically submitted vapor control system plans to MSC for review.
Documentation › Certificates/Documents › International Tonnage Certificate
Issued 1 November 2011 Resolved
Provide copies of all class documents once issued.
Due 1 December 2011
Resolved 6 December 2011
Resolution: Copies provided and scanned into MISLE.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 1 November 2011 Resolved
Service fire extinguishing systems.
Due 1 December 2011
Resolved 6 December 2011
Resolution: Copy of satisfactory servicing report provided.
Engineering › Fuel Oil Service System › Filter
Issued 1 November 2011 Resolved
Provide picture of new fuel filters once installed.
Due 1 December 2011
Resolved 25 November 2011
Resolution: Pictures provided, all appears sat.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 30 October 2010 Resolved
Provide a copy of the SOPEP approval letter prior to conducting cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2010
Resolved 1 November 2011
Resolution: SOPEP approval letter provided.

Ownership record