Records from 2014 to 2026. Most recent: inspection, 31 March 2026.
Inspection history · 53
31 March 2026
Re-Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8323969
12 December 2025
Periodic Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8282734
29 September 2025
Administrative Inspection · Periodic Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8234703
2 June 2025
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8150263
22 March 2025
Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8097995
22 March 2025
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8100472
5 March 2025
Periodic Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8089017
2 March 2025
Administrative Inspection · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8087011
6 January 2025
Administrative Inspection · Periodic Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8058891
17 October 2024
Re-Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8020630
10 June 2024
Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7931642
22 May 2024
Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7927183
4 March 2024
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7873604
13 September 2023
Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7801904
8 June 2023
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7709952
30 March 2023
Administrative Inspection · Re-Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7662436
16 December 2022
Re-Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7609977
27 September 2022
Re-Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7567885
21 June 2022
COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7480185
18 April 2022
In-Service Inspection · Annual Inspection · DAPI Audit · Administrative Inspection · Re-Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7452292
25 October 2021
Internal Structural Exam · Hull Examination · Drydock Exam · Administrative Inspection · In-Service Inspection · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7317500
21 October 2021
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7337084
29 July 2021
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7276406
21 June 2021
COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7232138
1 March 2021
Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7161034
7 December 2020
Administrative Inspection · In-Service Inspection · Deadweight Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7108617
4 November 2020
In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7089560
29 September 2020
Administrative Inspection · Periodic Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7067938
12 June 2020
COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6974705
26 February 2020
In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6916427
25 November 2019
In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6862017
3 September 2019
Administrative Inspection · Re-Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6802763
7 May 2019
Hull Examination · Examination of Repairs · Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6679088
26 March 2019
In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6651559
1 February 2019
Re-Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6618487
5 November 2018
Re-Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6575088
1 August 2018
Re-Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6497597
3 May 2018
Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6405146
14 February 2018
Administrative Inspection · Re-Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6355311
20 December 2017
Examination of Repairs · Administrative Inspection · Plan Review (Other than "T")
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6339417
15 November 2017
Re-Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6307614
11 September 2017
Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6269545
8 August 2017
Administrative Inspection · Deficiency Check · Re-Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6233863
3 May 2017
COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6138228
19 April 2017
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6129920
6 April 2017
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6118792
1 March 2017
MTSA Verification · Periodic Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6096891
20 October 2016
Deficiency Check · Welding Related Inspections Qualification Testing · Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6026190
19 August 2016
Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5977038
9 August 2016
Re-Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5974606
31 May 2016
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5893538
18 April 2016
COI Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5856728
11 February 2016
Administrative Inspection · MTSA Verification · Periodic Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5813278
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 31 March 2026
Resolved
Lifeboat and rescue boat release gear must be subjected to a thorough examination by properly trained personnel familiar with the system at each inspection for certification. Marine inspector observed no annual servicing in accordance with manufacturers instructions.
46CFR199.190(i)(4)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2026
Resolution: Vessel received and installed new approved release hook.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 31 March 2026
Resolved
Each inflated rescue boat must be repaired and maintained in accordance with the manufacturer's instructions. All repairs to inflated chambers must be made at a servicing facility approved by the Commandant, except for emergency repairs carried out on board the vessel. Marine inspector observed two repairs made to inflatable chamber, one of which in very poor condition and unable to hold pressure. Additionally, no annual servicing has been preformed IAW 46 CFR 199.190.
46CFR199.190(g)(4)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2026
Resolution: Vessel had third party inspect and repair as necessary the rescue boat.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 31 March 2026
Resolved
Each davit, winch, fall, and other launching appliance must be thoroughly inspected and repaired, as needed, once each year. Marine inspector observed no annual servicing in accordance with manufacturers instructions.
Vessel shall have properly trained personnel attend for
proper servicing of subject lifesaving equipment.
46CFR199.190(f)(2)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2026
Resolution: Davit, winch, and falls received annual servicing as required.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 March 2026
Resolved
Each firehose on each hydrant must have a combination solid stream and water spray firehose nozzle that meets the requirements in 46 CFR 162.027. Firehose nozzles previously approved under subpart 162.027 of this chapter may be retained so long as they are maintained in good condition to the satisfaction of the Officer in Charge, Marine Inspection. Marine Inspector observed leak in starboard forward main deck fire hose. Vessel shall replace.
46CFR76.10-10(j)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 May 2026
Resolution: Fire hose replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 September 2025
Resolved
Additional lifejackets for persons on watch must be stowed on the bridge, engine control room or other manned watch stations.
No crew lifejackets were stowed on the bridge.
46 CFR 70.28-1
46 CFR 199.(b)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 October 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 September 2025
Resolved
Stowage. Lifejackets must be readily accessible.
37 passenger passenger lifejackets were stowed in the crew lounge marked "restricted area." Move the lifejackets to accessible location or ensure lounge is accessible to passengers. Limited to 112 passengers.
46 CFR 70.28-1
46 CFR 199.(b)(2)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 3 October 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 17 June 2025
Resolved
The weatherdeck on a flush deck vessel must be made watertight. Vessel had 4 scuttles on the car/main deck that are in need of new gaskets and one with a broken dogging arm. Repair/replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2025
Resolved 28 July 2025
Resolution: Vessel operator sent in pics of the new gaskets installed on the scuttles and the new scuttle to replace the broken one.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 March 2025
Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its lifesaving appliances, fire-fighting or other equipment, or whenever any important repairs or renewals are made. The survey shall be such as to insure that the necessary repairs or renewals have been effectively made, that the material and the workmanship of such repairs or renewals are in all respects satisfactory, and that the vessel complies in all respects with the regulations in this subchapter. Vessel self-reported failed cutlass bearing on shaft for central main engine. Vessel is permitted to transit to dry dock and all repairs are to be made to the satisfaction of the CG marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 28 March 2025
Resolution: MI observed installation of new bearings and witnessed vessel clutching in.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 June 2023
Resolved
Vessel is required to service their fixed CO2 System annually. Vessel has a third party conduct the service and did not weigh and record the amount of Co2 in each bottle properly. Vessel shall re-weigh the Co2 bottles and record weights in the presence of a USCG Marine Inspector.
Action required: 10 - Deficiency Rectified
Due 4 July 2023
Resolved 27 June 2023
Resolution: Witness 3rd party conduct weight test of CO2 bottles and record proper weights. ALL SAT
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 June 2023
Resolved
Vessel is required to have a FCC station license. Vessel FCC license expired June 4, 2023. Provide valid FCC station license.
Action required: 10 - Deficiency Rectified
Due 20 July 2023
Resolved 27 June 2023
Resolution: Provided valid FCC station license.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 20 June 2023
Resolved
Vessel is required to have up to date charts. Vessel charts were not updated. Vessel shall provide updated charts.
Action required: 10 - Deficiency Rectified
Due 4 July 2023
Resolved 27 June 2023
Resolution: Provided updated navigation charts.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 27 September 2022
Resolved
Each hydrostatic release unit, other than a disposable unit must be serviced in according with part 160, subpart 160.062 of this subpart. Hydrostatic release units for 3 of 4 liferafts were expired and need replaced.
46 CFR 199.190(h)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 October 2022
Resolution: New hydrostatic releases installed on all liferafts.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 27 September 2022
Resolved
All enclosed spaces within the vessel shall be properly vented or ventilated and means shall be provided to close off all vents. New gaskets for ventilation closures for machinery space prevented closure of vents.
46 CFR 72.15-15
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 October 2022
Resolution: Modified ventilation closures to properly close.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 June 2022
Resolved
All automatically or remotely controlled or monitored vital systems addressed by part 62 of this subchapter must be subjected to tests and inspections to evaluate the operation and reliability of controls, alarms, safety features, and interlocks. Test procedures must be submitted to the Coast Guard for approval. Last approved revision (REV.B CTI-48-ALS) has since been updated to revision MAS-1248 dated January 12, 2022. New revisions must be submitted/approved by the Coast Guard (MSC).
46 CFR 61.40-1
Action required: 705 - Other - as specified
Due 21 August 2022
Resolved 4 June 2024
Resolution: Witnessed a satisfactory test of the alarm panel and completed all items on the PSTP (rev. 5). Signed and dated all pages and forwarded to MSC for final approval.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 June 2022
Resolved
Spaces which are protected by a carbon dioxide extinguishing system shall be fitted with an approved audible alarm, and shall be marked as required by 78.47-9 of this subchapter. "When alarm sounds vacate at once. Carbon dioxide or clean agent being released" Vessel missing required marking/signage near alarm of protected space.
46 CFR 76.15-30
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 July 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 October 2021
Resolved
Vessel was required to have a successful quarterly inspection NLT 23SEP2021. Quarterly was not conducted, vessel is restricted from carrying passengers until a satisfactory quartlery is completed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2022
Resolution: Vessel completed successful quarterly inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 22 March 2021
Resolved
Vessel is required to weight test rescue boat davit whenever falls are renewed. While conducting davit weight test (dynamic) the welds on the pedestal and foundation failed by way of cracking. Provide repair proposal and re-test IAW 46 CFR Subchapter W.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2021
Resolved 23 March 2021
Resolution: Welds were renewed around pedestal, and both a dynamic and static weight test were conducted with satisfactory results. Both visual and dye penetrate test was completed and welds were in satisfactory condition.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 December 2020
Resolved
Vessel is required to carry IBA's to accommodate a total of 150 people. IBAs's were sent of for servicing and all but one were returned. Current configuration will only allow the carriage of 130 total persons on board. Vessel is restricted to carrying 126 passengers and four crew until they receive the remaining IBA.
Action required: 705 - Other - as specified
Resolved 28 December 2020
Resolution: Received objective evidence that the servicing of the 50 person IBS has been completed and placed back on the vessel.
Electrical › Electric Supply System (service) › Cable
Issued 8 August 2017
Resolved
Remove deadend cable in Forpeak Void
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 11 September 2017
Resolution: Deadend cable was removed. Def Cleared.
Electrical › Electric Supply System (service) › Cable
Issued 8 August 2017
Resolved
Replace green and white wire in Forpeak Void with shielded marine type cabling
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 11 September 2017
Resolution: Shielded cable replaced the green and white cable. Def Cleared.
Stability › Watertight Integrity › General
Issued 8 August 2017
Resolved
Excessive shaft leakage. Tighted or repack the Port shaft.
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 11 September 2017
Resolution: Shaft packing was tightened. Def Cleared.
Construction/Loadline › Structures › Manhole
Issued 8 August 2017
Resolved
Properly secure all scuttle covers to prevent loosing overboard
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 11 September 2017
Resolution: Scuttles were connected with a chain to prevent loss. Def Cleared.
Communications › Radio Communications › VHF Radiotelephone
Issued 8 August 2017
Resolved
Ensure all VHF/UHF radios have the DSC switch patched in to GPS.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 11 September 2017
Resolution: VHF radio was linked to GPS. Def Cleared.
Electrical › Lighting (service) › Conductor
Issued 8 August 2017
Resolved
Replace degraded cabling for navigational lighting
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 11 September 2017
Resolution: Nav Light wiring was replaced. Def Cleared.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 8 August 2017
Resolved
Install circuit breaker blank inside the panelboard on the Bridge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 11 September 2017
Resolution: Blank was added to circuit breaker panel opening. Def Cleared.
Electrical › Electric Supply System (service) › Cable
Issued 8 August 2017
Resolved
Properly secure the cable for the E/R fan located on the main deck
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 11 September 2017
Resolution: Cable was properly secured. Def Cleared.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 August 2017
Resolved
Replace expired batteries for all buoy lights
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 11 September 2017
Resolution: All batteries were placed with new. Def Cleared.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 21 February 2017
Resolved
Fire boundaries using self-closing fire doors shall be maintained at all times. The A-15 fire door from the vestibule top teh engine room was wasted and repaired. The repair was approved as a temporary repair unitl a new door can be manufactured and delivered (8 weeks). The repairs were tested and found to be acceptable unitl the new door can be installed and tested.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 8 August 2017
Resolution: Inspected new fire door. ALL SAT
Fire Fighting › Structural - A Class Divisions › Doors
Issued 31 January 2017
Resolved
Fire boundaries between the engine room and vestibule shall be maintained at all times. The A-15 self-closing door between the engien room and vestibule is wasted beyond repair. Replace the A-15 self-closing door between the engien room and vestibule.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 March 2017
Resolved 21 February 2017
Resolution: Temporary repairs were made and approved by hte manufactureer as a temporary repair. A soap and blow test was conducted and the door was found to be gas tight.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 19 August 2016
Resolved
Damaged cylinder head on the port MDE; required to make repairs prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 26 August 2016
Resolution: Inspected remanufactured engine installation. Conducted PTSP for engine and verified operations of vessel. No issues noted.
Lifesaving › Launching Appliances › Davit
Issued 12 May 2016
Resolved
Limit switch on rescue boat davit winch is not properly calibrated to safely stop the winch from parting the wire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 May 2016
Resolved 31 May 2016
Resolution: Vessel rep showed proper opperation of rescue boat davit limit switch.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 18 April 2016
Resolved
Keel cooler piping to all 03 MDEs were missing proper insulation to protect crew from hazard.
Action required: 705 - Other - as specified
Due 13 June 2016
Resolved 31 May 2016
Resolution: foam lagging was replaced with approved lagging on all hazardous engine piping.