Records from 1992 to 2026. Most recent: inspection, 31 March 2026.
Inspection history · 83
31 March 2026
Re-Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8323969
12 December 2025
Periodic Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8282734
29 September 2025
Administrative Inspection · Periodic Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8234703
2 June 2025
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8150263
22 March 2025
Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8097995
22 March 2025
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8100472
5 March 2025
Periodic Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8089017
2 March 2025
Administrative Inspection · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8087011
6 January 2025
Administrative Inspection · Periodic Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8058891
17 October 2024
Re-Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8020630
10 June 2024
Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7931642
22 May 2024
Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7927183
4 March 2024
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7873604
13 September 2023
Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7801904
8 June 2023
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7709952
30 March 2023
Administrative Inspection · Re-Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7662436
16 December 2022
Re-Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7609977
27 September 2022
Re-Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7567885
21 June 2022
COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7480185
18 April 2022
In-Service Inspection · Annual Inspection · DAPI Audit · Administrative Inspection · Re-Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7452292
25 October 2021
Internal Structural Exam · Hull Examination · Drydock Exam · Administrative Inspection · In-Service Inspection · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7317500
21 October 2021
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7337084
29 July 2021
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7276406
21 June 2021
COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7232138
1 March 2021
Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7161034
7 December 2020
Administrative Inspection · In-Service Inspection · Deadweight Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7108617
4 November 2020
In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7089560
29 September 2020
Administrative Inspection · Periodic Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7067938
12 June 2020
COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6974705
26 February 2020
In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6916427
25 November 2019
In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6862017
3 September 2019
Administrative Inspection · Re-Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6802763
7 May 2019
Hull Examination · Examination of Repairs · Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6679088
26 March 2019
In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6651559
1 February 2019
Re-Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6618487
5 November 2018
Re-Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6575088
1 August 2018
Re-Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6497597
3 May 2018
Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6405146
14 February 2018
Administrative Inspection · Re-Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6355311
20 December 2017
Examination of Repairs · Administrative Inspection · Plan Review (Other than "T")
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6339417
15 November 2017
Re-Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6307614
11 September 2017
Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6269545
8 August 2017
Administrative Inspection · Deficiency Check · Re-Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6233863
3 May 2017
COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6138228
19 April 2017
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6129920
6 April 2017
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6118792
1 March 2017
MTSA Verification · Periodic Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6096891
20 October 2016
Deficiency Check · Welding Related Inspections Qualification Testing · Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6026190
19 August 2016
Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5977038
9 August 2016
Re-Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5974606
31 May 2016
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5893538
18 April 2016
COI Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5856728
11 February 2016
Administrative Inspection · MTSA Verification · Periodic Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5813278
19 November 2015
Re-Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5766437
18 August 2015
Deficiency Check · Re-Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5219657
23 July 2015
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5194682
13 July 2015
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5209912
19 August 2014
Administrative Inspection · MTSA Verification · Periodic Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4946699
27 May 2014
Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4877453
27 May 2014
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4885154
22 May 2014
Welding Related Inspections Qualification Testing · Internal Structural Exam · Administrative Inspection · MTSA Verification · Drydock Exam · Hull Examination · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4864710
12 July 2012
Periodic Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4376528
1 May 2012
Deficiency Check · MTSA Verification · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4295214
4 January 2012
Drydock Exam · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4218410
19 August 2011
Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4130088
28 July 2011
Deficiency Check · Periodic Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4097494
1 February 2011
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3937023
25 October 2010
Re-Inspection · MTSA Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3877146
5 January 2010
COI Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3658931
10 April 2009
COI Inspection · Plan Review (Other than "T") · MTSA Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3449890
17 June 2008
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3239438
23 May 2008
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3214864
23 February 2008
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3152304
13 February 2008
Plan Review (Other than "T")
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3147085
26 November 2007
Plan Review (Other than "T")
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3104519
30 October 2007
COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3085633
29 January 2007
Re-Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2863631
30 October 2006
Hull Examination · MTSA Verification · Plan Review (Other than "T") · Internal Structural Exam · Initial Certification · Deadweight Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2811132
8 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1961103
20 September 1994
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 88964
24 October 1992
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 215998
10 August 1992
Uninspected Other
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1247289
18 May 1992
Uninspected Other
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1267623
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 31 March 2026
Resolved
Lifeboat and rescue boat release gear must be subjected to a thorough examination by properly trained personnel familiar with the system at each inspection for certification. Marine inspector observed no annual servicing in accordance with manufacturers instructions.
46CFR199.190(i)(4)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2026
Resolution: Vessel received and installed new approved release hook.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 31 March 2026
Resolved
Each inflated rescue boat must be repaired and maintained in accordance with the manufacturer's instructions. All repairs to inflated chambers must be made at a servicing facility approved by the Commandant, except for emergency repairs carried out on board the vessel. Marine inspector observed two repairs made to inflatable chamber, one of which in very poor condition and unable to hold pressure. Additionally, no annual servicing has been preformed IAW 46 CFR 199.190.
46CFR199.190(g)(4)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2026
Resolution: Vessel had third party inspect and repair as necessary the rescue boat.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 31 March 2026
Resolved
Each davit, winch, fall, and other launching appliance must be thoroughly inspected and repaired, as needed, once each year. Marine inspector observed no annual servicing in accordance with manufacturers instructions.
Vessel shall have properly trained personnel attend for
proper servicing of subject lifesaving equipment.
46CFR199.190(f)(2)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2026
Resolution: Davit, winch, and falls received annual servicing as required.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 March 2026
Resolved
Each firehose on each hydrant must have a combination solid stream and water spray firehose nozzle that meets the requirements in 46 CFR 162.027. Firehose nozzles previously approved under subpart 162.027 of this chapter may be retained so long as they are maintained in good condition to the satisfaction of the Officer in Charge, Marine Inspection. Marine Inspector observed leak in starboard forward main deck fire hose. Vessel shall replace.
46CFR76.10-10(j)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 May 2026
Resolution: Fire hose replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 September 2025
Resolved
Additional lifejackets for persons on watch must be stowed on the bridge, engine control room or other manned watch stations.
No crew lifejackets were stowed on the bridge.
46 CFR 70.28-1
46 CFR 199.(b)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 October 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 September 2025
Resolved
Stowage. Lifejackets must be readily accessible.
37 passenger passenger lifejackets were stowed in the crew lounge marked "restricted area." Move the lifejackets to accessible location or ensure lounge is accessible to passengers. Limited to 112 passengers.
46 CFR 70.28-1
46 CFR 199.(b)(2)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 3 October 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 17 June 2025
Resolved
The weatherdeck on a flush deck vessel must be made watertight. Vessel had 4 scuttles on the car/main deck that are in need of new gaskets and one with a broken dogging arm. Repair/replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2025
Resolved 28 July 2025
Resolution: Vessel operator sent in pics of the new gaskets installed on the scuttles and the new scuttle to replace the broken one.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 March 2025
Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its lifesaving appliances, fire-fighting or other equipment, or whenever any important repairs or renewals are made. The survey shall be such as to insure that the necessary repairs or renewals have been effectively made, that the material and the workmanship of such repairs or renewals are in all respects satisfactory, and that the vessel complies in all respects with the regulations in this subchapter. Vessel self-reported failed cutlass bearing on shaft for central main engine. Vessel is permitted to transit to dry dock and all repairs are to be made to the satisfaction of the CG marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 28 March 2025
Resolution: MI observed installation of new bearings and witnessed vessel clutching in.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 June 2023
Resolved
Vessel is required to service their fixed CO2 System annually. Vessel has a third party conduct the service and did not weigh and record the amount of Co2 in each bottle properly. Vessel shall re-weigh the Co2 bottles and record weights in the presence of a USCG Marine Inspector.
Action required: 10 - Deficiency Rectified
Due 4 July 2023
Resolved 27 June 2023
Resolution: Witness 3rd party conduct weight test of CO2 bottles and record proper weights. ALL SAT
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 June 2023
Resolved
Vessel is required to have a FCC station license. Vessel FCC license expired June 4, 2023. Provide valid FCC station license.
Action required: 10 - Deficiency Rectified
Due 20 July 2023
Resolved 27 June 2023
Resolution: Provided valid FCC station license.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 20 June 2023
Resolved
Vessel is required to have up to date charts. Vessel charts were not updated. Vessel shall provide updated charts.
Action required: 10 - Deficiency Rectified
Due 4 July 2023
Resolved 27 June 2023
Resolution: Provided updated navigation charts.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 27 September 2022
Resolved
Each hydrostatic release unit, other than a disposable unit must be serviced in according with part 160, subpart 160.062 of this subpart. Hydrostatic release units for 3 of 4 liferafts were expired and need replaced.
46 CFR 199.190(h)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 October 2022
Resolution: New hydrostatic releases installed on all liferafts.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 27 September 2022
Resolved
All enclosed spaces within the vessel shall be properly vented or ventilated and means shall be provided to close off all vents. New gaskets for ventilation closures for machinery space prevented closure of vents.
46 CFR 72.15-15
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 October 2022
Resolution: Modified ventilation closures to properly close.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 June 2022
Resolved
All automatically or remotely controlled or monitored vital systems addressed by part 62 of this subchapter must be subjected to tests and inspections to evaluate the operation and reliability of controls, alarms, safety features, and interlocks. Test procedures must be submitted to the Coast Guard for approval. Last approved revision (REV.B CTI-48-ALS) has since been updated to revision MAS-1248 dated January 12, 2022. New revisions must be submitted/approved by the Coast Guard (MSC).
46 CFR 61.40-1
Action required: 705 - Other - as specified
Due 21 August 2022
Resolved 4 June 2024
Resolution: Witnessed a satisfactory test of the alarm panel and completed all items on the PSTP (rev. 5). Signed and dated all pages and forwarded to MSC for final approval.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 June 2022
Resolved
Spaces which are protected by a carbon dioxide extinguishing system shall be fitted with an approved audible alarm, and shall be marked as required by 78.47-9 of this subchapter. "When alarm sounds vacate at once. Carbon dioxide or clean agent being released" Vessel missing required marking/signage near alarm of protected space.
46 CFR 76.15-30
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 July 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 October 2021
Resolved
Vessel was required to have a successful quarterly inspection NLT 23SEP2021. Quarterly was not conducted, vessel is restricted from carrying passengers until a satisfactory quartlery is completed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2022
Resolution: Vessel completed successful quarterly inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 22 March 2021
Resolved
Vessel is required to weight test rescue boat davit whenever falls are renewed. While conducting davit weight test (dynamic) the welds on the pedestal and foundation failed by way of cracking. Provide repair proposal and re-test IAW 46 CFR Subchapter W.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2021
Resolved 23 March 2021
Resolution: Welds were renewed around pedestal, and both a dynamic and static weight test were conducted with satisfactory results. Both visual and dye penetrate test was completed and welds were in satisfactory condition.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 December 2020
Resolved
Vessel is required to carry IBA's to accommodate a total of 150 people. IBAs's were sent of for servicing and all but one were returned. Current configuration will only allow the carriage of 130 total persons on board. Vessel is restricted to carrying 126 passengers and four crew until they receive the remaining IBA.
Action required: 705 - Other - as specified
Resolved 28 December 2020
Resolution: Received objective evidence that the servicing of the 50 person IBS has been completed and placed back on the vessel.
Electrical › Electric Supply System (service) › Cable
Issued 8 August 2017
Resolved
Remove deadend cable in Forpeak Void
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 11 September 2017
Resolution: Deadend cable was removed. Def Cleared.
Electrical › Electric Supply System (service) › Cable
Issued 8 August 2017
Resolved
Replace green and white wire in Forpeak Void with shielded marine type cabling
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 11 September 2017
Resolution: Shielded cable replaced the green and white cable. Def Cleared.
Stability › Watertight Integrity › General
Issued 8 August 2017
Resolved
Excessive shaft leakage. Tighted or repack the Port shaft.
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 11 September 2017
Resolution: Shaft packing was tightened. Def Cleared.
Construction/Loadline › Structures › Manhole
Issued 8 August 2017
Resolved
Properly secure all scuttle covers to prevent loosing overboard
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 11 September 2017
Resolution: Scuttles were connected with a chain to prevent loss. Def Cleared.
Communications › Radio Communications › VHF Radiotelephone
Issued 8 August 2017
Resolved
Ensure all VHF/UHF radios have the DSC switch patched in to GPS.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 11 September 2017
Resolution: VHF radio was linked to GPS. Def Cleared.
Electrical › Lighting (service) › Conductor
Issued 8 August 2017
Resolved
Replace degraded cabling for navigational lighting
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 11 September 2017
Resolution: Nav Light wiring was replaced. Def Cleared.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 8 August 2017
Resolved
Install circuit breaker blank inside the panelboard on the Bridge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 11 September 2017
Resolution: Blank was added to circuit breaker panel opening. Def Cleared.
Electrical › Electric Supply System (service) › Cable
Issued 8 August 2017
Resolved
Properly secure the cable for the E/R fan located on the main deck
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 11 September 2017
Resolution: Cable was properly secured. Def Cleared.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 August 2017
Resolved
Replace expired batteries for all buoy lights
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 September 2017
Resolved 11 September 2017
Resolution: All batteries were placed with new. Def Cleared.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 21 February 2017
Resolved
Fire boundaries using self-closing fire doors shall be maintained at all times. The A-15 fire door from the vestibule top teh engine room was wasted and repaired. The repair was approved as a temporary repair unitl a new door can be manufactured and delivered (8 weeks). The repairs were tested and found to be acceptable unitl the new door can be installed and tested.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 8 August 2017
Resolution: Inspected new fire door. ALL SAT
Fire Fighting › Structural - A Class Divisions › Doors
Issued 31 January 2017
Resolved
Fire boundaries between the engine room and vestibule shall be maintained at all times. The A-15 self-closing door between the engien room and vestibule is wasted beyond repair. Replace the A-15 self-closing door between the engien room and vestibule.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 March 2017
Resolved 21 February 2017
Resolution: Temporary repairs were made and approved by hte manufactureer as a temporary repair. A soap and blow test was conducted and the door was found to be gas tight.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 19 August 2016
Resolved
Damaged cylinder head on the port MDE; required to make repairs prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 26 August 2016
Resolution: Inspected remanufactured engine installation. Conducted PTSP for engine and verified operations of vessel. No issues noted.
Lifesaving › Launching Appliances › Davit
Issued 12 May 2016
Resolved
Limit switch on rescue boat davit winch is not properly calibrated to safely stop the winch from parting the wire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 May 2016
Resolved 31 May 2016
Resolution: Vessel rep showed proper opperation of rescue boat davit limit switch.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 18 April 2016
Resolved
Keel cooler piping to all 03 MDEs were missing proper insulation to protect crew from hazard.
Action required: 705 - Other - as specified
Due 13 June 2016
Resolved 31 May 2016
Resolution: foam lagging was replaced with approved lagging on all hazardous engine piping.
Engineering › Bilge Water Management System › Piping
Issued 19 November 2015
Resolved
Port Eng Room Bilge pipe had a hole drilled into it while securing deck plating. Make repairs to the port engine room bilge pipe and make all bilge pipe available for inspection.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 December 2015
Resolved 8 December 2015
Resolution: holed pipe was replaced and inspected satisfactory. deficiency cleared.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 19 November 2015
Resolved
Make repairs to torn A-60 in engine room. 46 CFR72.05-10
Action required: 705 - Other - as specified
Due 19 December 2015
Resolved 8 December 2015
Resolution: overhead insulatin was repaired. def cleared.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 19 November 2015
Resolved
Provide lagging on exhaust piping on center main engine. 46 CFR 56.50-1K
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 November 2015
Resolved 8 December 2015
Resolution: missing lagging was installed. def cleared.
Engineering › Bilge Water Management System › Strainer
Issued 19 November 2015
Resolved
Install missing strainer on bilge piping. 46 CFR 56.50-50
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 November 2015
Resolved 16 December 2015
Resolution: Strainers were installed. Def Cleared.
Engineering › Bilge Water Management System › Not Operational
Issued 19 November 2015
Resolved
Due to hole in bilge pipe, unable to verify operation. Prove operation of all bilge pipes. 46 CFR 56.50-50
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 November 2015
Resolved 16 December 2015
Resolution: Satisfactorily tested all bilge piping. Def Cleared.
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 19 November 2015
Resolved
Prove high jacket water alarm at 210 def F per PSTP on fwd Generator. 46 CFR 62.35-50
Action required: 705 - Other - as specified
Due 26 November 2015
Resolved 8 December 2015
Resolution: alarm tested sat. def cleared.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 19 November 2015
Resolved
Replace expired batteries in Lifebuoy lights. 46 CFr 161.010
Action required: 705 - Other - as specified
Due 26 November 2015
Resolved 8 December 2015
Resolution: batteries were replaced. def cleared.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 19 November 2015
Resolved
Replace outdated Coast Pilot. 33 CFr 164.33
Action required: 705 - Other - as specified
Due 26 November 2015
Resolved 8 December 2015
Resolution: current coast pilot for area of operation was provided. def cleared.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 19 November 2015
Resolved
Fwd battery charger was inoperable. 46 CFR 111.15-9
Due 8 January 2016
Resolved 16 December 2015
Resolution: Battery charged tested sat.
Engineering › Diesel Engine (auxiliary) › Governor
Issued 19 November 2015
Resolved
Governor was improperly installed and throttle cable was missing. 46 CFr 58.10-10
Action required: 705 - Other - as specified
Due 8 January 2016
Resolved 16 December 2015
Resolution: Govern and throttle was installed. Def Cleared.
Electrical › Electric Generation Source (service) › Neutral Ground
Issued 19 November 2015
Resolved
Ground for aft battery charger was improperly spliced. 46 CFR 129.340
Action required: 705 - Other - as specified
Due 8 January 2016
Resolved 16 December 2015
Resolution: Splice was placed inside approved box.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 19 November 2015
Resolved
replace oil soaked pads from under engines.
Action required: 705 - Other - as specified
Due 8 January 2016
Resolved 16 December 2015
Resolution: oil soaked pads replaced.
Electrical › Electric Generation Source (service) › Panelboard
Issued 19 November 2015
Resolved
Remove dead ended wires from aft switchboard. 46 CFR 129.340
Action required: 705 - Other - as specified
Due 8 January 2016
Resolved 16 December 2015
Resolution: dead end wires removed.
Fire Fighting › Fire Pumps › Pressure
Issued 18 August 2015
Resolved
Firepump failed to maintain a pressure > 50 Pitot at the nozzle. Required 3rd party to effect repairs and prove pressure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 October 2015
Resolution: Division supervisor approved a re-determination of the discrepancy. Scanned in request
Accommodation/Occupational Safety › Occupational Safety › Smoking
Issued 7 May 2012
Resolved
Provide "No Smoking" signs, IAW 46 CFR 78.40-10
Action required: 705 - Other - as specified
Due 7 June 2012
Resolved 7 June 2012
Resolution: "No Smoking" signs were posted throughout the vessel.
Operations/Management › Drills/Instruction › Activating General Alarm
Issued 7 May 2012
Resolved
Provide General Alarm placard in the wheelhouse and renew the GA placard in the engine room, IAW 46 CFR 113.25.
Action required: 705 - Other - as specified
Due 7 June 2012
Resolved 7 June 2012
Resolution: General Alarm placards were palced in the wheelhouse and in the engine room.
Lifesaving › Rescue Boat Equipment › Electric Torch
Issued 7 May 2012
Resolved
Provide flashlight, search light, radar reflector, and heaving line for rescue boat, IAW 46 CFR 199.175.
Action required: 705 - Other - as specified
Due 7 June 2012
Resolved 7 June 2012
Resolution: A flashlight, search light, radar reflector, and heaving line for rescue boat was provided.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 7 May 2012
Resolved
Make updates to charts IAW notice to mariners, as per 46 CFR 78.05-5.
Action required: 705 - Other - as specified
Due 7 June 2012
Resolved 7 June 2012
Resolution: Updates to charts IAW notice to mariners were complete and current.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 7 May 2012
Resolved
Submit periodic safety test procedures to local OCMI for approval, IAW 46 CFR 61.40-1.
Action required: 705 - Other - as specified
Due 7 July 2012
Resolved 20 June 2012
Resolution: The periodic safety test procedures were submitted to our office and tested on the vessel satisfactorily. The procedures were stamped approved.
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 7 May 2012
Resolved
Provide a low oil level alarm for both steering hydraulic tanks, IAW 46 CFR 58.25-25.
Action required: 705 - Other - as specified
Due 7 July 2012
Resolved 20 June 2012
Resolution: Low oil level alarms for both steering hydraulic tanks were installed and tested satisfactorily.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 7 May 2012
Resolved
Secure the toolbox in the engine room, IAW 46 CFR 50.20-35.
Action required: 705 - Other - as specified
Due 7 June 2012
Resolved 7 June 2012
Resolution: The toolbox in the engine room was secured for sea.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 7 May 2012
Resolved
Prove operation of the STBD MDE low clutch oil pressure alarm, IAW 46 CFR 62.25-20.
Action required: 705 - Other - as specified
Due 7 June 2012
Resolved 20 June 2012
Resolution: Operation of the STBD MDE low clutch oil pressure alarm was demonstrated satisfactorily.
Electrical › Lighting (service) › Lighting Fixture
Issued 7 May 2012
Resolved
Properly install the lighting fixture over the STBD MSD, IAW 46 CFR 111.75-20.
Action required: 705 - Other - as specified
Due 7 June 2012
Resolved 7 June 2012
Resolution: The lighting fixture over the STBD MSD is properly installed.
Engineering › Lubricating Oil Service System › Piping
Issued 7 May 2012
Resolved
Crop and renew the return hydraulic pipe on the stern hydraulic pump, IAW 46 CFR 58.25-20.
Action required: 705 - Other - as specified
Due 7 June 2012
Resolved 7 June 2012
Resolution: The return hydraulic pipe on the stern hydraulic pump has been renewed and a air test to prove the installation was found to be in satisfactory condition.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 7 May 2012
Resolved
Provide oil temp gauges for all propulsion diesel engines, IAW 46 CFR 62.35-30.
Action required: 705 - Other - as specified
Due 7 July 2012
Resolved 20 June 2012
Resolution: Oil temp guages were provided and proven to be in operational condition for all propulsion diesel engines.
Deck/Cargo › Cargo Stowage › General
Issued 19 August 2011
Resolved
The required clearance in 46 CFR 78.40-1(a) needs to be provided for passenger safety and to provide access to fire stations, vent closures and E/R door while underway.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2011
Resolved 7 May 2012
Resolution: Markings were displayed to allow passenger safety and to provide access to fire stations, vent closures, and E/R door while underway.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 28 July 2011
Resolved
Provide all required documents & publications for master & crew use
Action required: 705 - Other - as specified
Due 12 August 2011
Resolved 1 August 2011
Resolution: Provided
Communications › Radio Communications › VHF Radiotelephone
Issued 28 July 2011
Resolved
Post call sign at radio station.
Action required: 705 - Other - as specified
Due 12 August 2011
Resolved 1 August 2011
Resolution: Provided
Construction/Loadline › Structures › Deck Plating
Issued 28 July 2011
Resolved
Properly repair hatch and soft patch on deck to maintain watertight integrity.
Action required: 705 - Other - as specified
Due 12 August 2011
Resolved 1 August 2011
Resolution: Hatch properly adjusted during drills.
Engineering › Steering Gear System › Hydraulic Hose
Issued 28 July 2011
Resolved
Provide pressure gauges for bow ramp and steering hydraulic systems.
Action required: 705 - Other - as specified
Due 12 August 2011
Resolved 7 May 2012
Resolution: Pressure gauges were installed for the steering and bow ramp hydraulic systems.
Engineering › Lubricating Oil Service System › Tube
Issued 28 July 2011
Resolved
Provide glass tube and guards for lube oil tank sight glass.
Action required: 705 - Other - as specified
Due 12 August 2011
Resolved 7 May 2012
Resolution: Sounding will be taken from the lube oil tank vice installing a glass tube with guards for gauging.
Construction/Loadline › Structures › Deck Plating
Issued 28 July 2011
Resolved
Repair overhead leaks in aft portside pilot house located over fire detection panel.
Action required: 705 - Other - as specified
Due 12 August 2011
Resolved 1 August 2011
Resolution: Area sealed weather tight
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 28 July 2011
Resolved
Properly repair inoperable fire detection system. Provide 3rd party servicing report and test satisfactorily in the presence of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 August 2011
Resolved 1 August 2011
Resolution: New system installed and tested by the inspector.
Electrical › Electric Generation Source (service) › Switch
Issued 8 April 2010
Resolved
Prove operation of forward generator lube oil low pressure switch as per 46 CFR 111.12-1.
Action required: 705 - Other - as specified
Due 29 April 2010
Resolved 28 April 2010
Resolution: Proved operation of forward generator lube oil low pressure switch as per 46 CFR 111.12-1.
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 April 2010
Resolved
Secure all loose wires in engine room and main control room as per 46 CFR 111.01-1.
Action required: 705 - Other - as specified
Due 29 April 2010
Resolved 29 April 2010
Resolution: Secured all loose wires in engine room and main control room as per 46 CFR 111.01-1.
Fire Fighting › Fire Pumps › Capacity
Issued 8 April 2010
Resolved
Replace the guage on the discharge side of the fire pump on the center main engine as per 46 CFR 76.10-5.
Action required: 705 - Other - as specified
Due 29 April 2010
Resolved 28 April 2010
Resolution: Replace the guage on the discharge side of the fire pump on the center main engine as per 46 CFR 76.10-5.
Fire Fighting › Fire Main › Valves
Issued 8 April 2010
Resolved
Replace the valve handle on the fire main as per 46 CFR 56.20.
Action required: 705 - Other - as specified
Due 29 April 2010
Resolved 29 April 2010
Resolution: Replaced the valve handle on the fire main as per 46 CFR 56.20.
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 8 April 2010
Resolved
Install two 30-amp breakers for the automatic powere supply as per MSC letter E2-0901198.
Action required: 705 - Other - as specified
Due 29 April 2010
Resolved 28 April 2010
Resolution: Installed two 30-amp breakers for the automatic powere supply as per MSC letter E2-0901198.
Electrical › Electrical Distribution System (emergency) › Panelboard
Issued 8 April 2010
Resolved
Prove operation of fire and bilge pump on emergency load as per 46 CFR 112.15-5.
Action required: 705 - Other - as specified
Due 15 June 2010
Resolved 20 May 2010
Resolution: This requirement was appealed by the vessel''s rep. and granted by SECTOR Mobile.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 8 April 2010
Resolved
Prove all MSC technical comments as they are required from the CG-835 that was issued in 2007.
Action required: 705 - Other - as specified
Due 29 July 2010
Resolved 28 October 2010
Resolution: Witnessed MSC approval letter
Fire Fighting › Fire Main › Pressure
Issued 31 October 2007
Resolved
Provide a fire pump capable of producing 50 PSI using a Pitot tub with both hoses as required by 46 CFR 76.10-5.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2007
Resolved 26 November 2007
Resolution: Vessel crew renewed fire pump and was capable of demonstrating 50 psi from pitot tube to the satisfaction of the marine inspector.
Lifesaving › Launching Appliances › Davit
Issued 31 October 2007
Resolved
Prove proper operation of the davit and capability of recovering a fully loaded rescue boat.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2007
Resolved 2 November 2007
Resolution: Proved proper operation of the davit with a loaded rescue boat.
Lifesaving › Rescue Boat › Markings
Issued 30 October 2007
Resolved
Properly mark rescue boat as required by 46 CFR 199.176
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 2 November 2007
Resolution: Marked the rescue boat.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 30 October 2007
Resolved
Provide contrasting color for draft marks on the hull as required by 46 CFR 78.50
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 26 November 2007
Resolution: Contrasting draft marks on hull were witnessed satisfactory by attending marine inspector.
Electrical › Electric Supply System (service) › Cable
Issued 30 October 2007
Resolved
Properly support all electricial wiring in the pilothouse, engine room, and generator space as required by 46 CFR 111
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 26 November 2007
Resolution: Wiring in pilot house, engine room, and generator space has been properly supported.
Stability › Watertight Integrity › General
Issued 30 October 2007
Resolved
Make permanent repair to holes in pilothouse in way of windows.
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 30 November 2007
Resolution: Repaired holes
Engineering › Steering Gear System › Valve
Issued 30 October 2007
Resolved
Repair hydraulic leak at (stick) steering controls located in the pilothouse.
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 27 April 2009
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 30 October 2007
Resolved
Properly mount the power supply (UPS) located under the main console.
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 2 November 2007
Resolution: Mounted the power supply.
Navigation › Collision/Grounding Avoidance › Day Shapes
Issued 30 October 2007
Resolved
Provide day shapes for restricted or limited maneuverability as required by 72 COLREGS.
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 2 November 2007
Resolution: Provided day shapes.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 30 October 2007
Resolved
Prove proper operation of the fire detection system. Clear the trouble light. As required by 46 CFR 95.05.1
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2007
Resolved 29 November 2007
Resolution: Correct operation of fire detection and the clear trouble light was witness satisfactory this date.
Communications › Alarms/Indicators › General Alarm
Issued 30 October 2007
Resolved
Properly mount the general alarm contact maker located on the pilot house console.
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 2 November 2007
Resolution: Mounted contact maker.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 30 October 2007
Resolved
Remove all combustible material from the vicinity of the heaters located in the crew and passenger heads.
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 2 November 2007
Resolution: Removed the heaters for both heads.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 30 October 2007
Resolved
Demonstrate all machinery alarms and systems associated with the vessels periodic test procedures.
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 29 November 2007
Resolution: All machinery alarms has been successfully deomonstrated this date and PSTP are currently under revision.
Fire Fighting › Structural - Horizontal Zones › General
Issued 30 October 2007
Resolved
Repair all damaged insulation in way of the engine room with the insulation that meets the approved standard and the approved fire boundary plan.
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 26 November 2007
Resolution: Damaged insulation has been renewed with appropriate insulation that meets the standard.
Accommodation/Occupational Safety › Ventilation › General
Issued 30 October 2007
Resolved
Clean engine room exhaust vent and fan of built up dirt and grease.
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 2 November 2007
Resolution: Cleaned exhaust fan and vent.
Engineering › Lubricating Oil Storage/Transfer System › Gauge
Issued 30 October 2007
Resolved
Provide sight glass for lube oil storage tank.
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 26 November 2007
Resolution: Site glass for lube oil tank has been renewed.
Electrical › Electric Supply System (service) › Cable
Issued 30 October 2007
Resolved
Replace burnt wiring on port main engine.
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 2 November 2007
Resolution: Replace the burnt wire on port main engine.
Communications › Alarms/Indicators › General Alarm
Issued 30 October 2007
Resolved
Prove proper operation of the general alarm system in the engine room and properly label as required by 46 CFR 113.25
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 27 November 2007
Resolution: Vessel demonstrated proper operation of general alarm in the engine room and the unit has been properly labelled.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 30 October 2007
Resolved
Remove or secure refrigerator located in the engine room.
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 2 November 2007
Resolution: Removed refrigerator from engine room.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 30 October 2007
Resolved
Prove proper operation of the type II marine sanitation device as required by 33 CFR 159.55
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 27 November 2007
Resolution: Marine sanitation device has been successfully demonstrated.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 30 October 2007
Resolved
Provide annual testing of the vessels fire fighting systems with the presence of a CG marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2007
Resolved 2 November 2007
Resolution: Weighed all CO2 cylinders.
Lifesaving › Rescue Boat › Weathertight Stowage
Issued 30 October 2007
Resolved
Provide fixed support/cradle for the rescue boat.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2007
Resolved 2 November 2007
Resolution: Mounted the rescue boat cradle to the deck.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 30 October 2007
Resolved
Prove proper operation of the air receiver relief valves as required by 46 CFR 58.30.
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 26 November 2007
Resolution: Relief valves were renewed and demonstrated to the satisfaction of the attending marine inspector.
Engineering › Fuel Oil Service System › Piping
Issued 30 October 2007
Resolved
Properly support fuel piping at main engines as required by 46 CFR 58.
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 26 November 2007
Resolution: Fuel piping on main engines have been properly supported.
Electrical › Electric Generation Source (service) › Generator
Issued 30 October 2007
Resolved
Remove excess dirt, oil, grease from windings on ship service generators.
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 29 November 2007
Resolution: Excessive dirt, oil, and grease have been removed from the windings on the ships service generator.
Accommodation/Occupational Safety › Ventilation › General
Issued 30 October 2007
Resolved
Properly label motor controllers in engine room vestibule as required by 46 CFR 111
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 26 November 2007
Resolution: Motor controllers have been labeled properly
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 30 October 2007
Resolved
Provide electrical matting for main switchboard as required by 46 CFR 111.30.
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 26 November 2007
Resolution: Electrical matting for main switchboard had been installed.
Communications › Alarms/Indicators › General Alarm
Issued 30 October 2007
Resolved
Remove overspray from the general alarm bell, light and fire strobe.
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 26 November 2007
Resolution: Overspray on genral alarm bell, light and strobe has been removed to the satisfaction of attending marine inspector.
Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 30 October 2007
Resolved
Prove all portable fire extinguishers are USCG approved as required by 46 CFR 76.50
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2007
Resolved 2 November 2007
Resolution: All portable extinguishers are USCG approved.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 30 October 2007
Resolved
Repair all excessive oil leaks from the port main engine.
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 26 November 2007
Resolution: All excessive oil leaks have been corrected satisfactory.
Engineering › Fuel Oil Service System › Hose
Issued 29 January 2007
Resolved
Make repairs to the fuel oil leak on the forward ship service generator as required by 46 CFR 56.50-60.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 February 2007
Resolution: Made repairs to the fuel oil leak on the forward ship service generator.
Engineering › Fuel Oil Service System › Filter
Issued 29 January 2007
Resolved
Remove the petcock on the lube oil filter housing and install a plug on the port and starboard main diesel engines as required by 46 CFR 56.50.60.
Due 1 March 2007
Resolved 5 February 2007
Resolution: Removed the pepcock on the lube oil filter housing and install a plug on the port and starboard main diesel engines.
Construction/Loadline › Hull › Weld
Issued 29 January 2007
Resolved
Make repairs to the forward and aft ramp as discussed in accordance with NVIC 7-68
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 February 2007
Resolution: Made repairs to the forward and aft ramp as discussed
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 29 January 2007
Resolved
Properly band inflatable buoyant apparatus in accordance with 46 CFR 199.201
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 February 2007
Resolution: Properly banded the inflatable buoyant apparatus
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 29 January 2007
Resolved
Prove proper operation of the emergency generator in accordance with 46 CFR 112
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 February 2007
Resolution: Proved proper operation of the emergency generator