Records from 2006 to 2026. Most recent: inspection, 13 April 2026.
Inspection history · 30
13 April 2026
Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8314954
12 February 2026
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8309723
11 February 2025
Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8075077
30 April 2024
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7904009
31 January 2024
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7858378
27 June 2023
Administrative Inspection
Administrative · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 7724611
26 April 2023
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7675815
23 December 2022
In-Service Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7613271
27 October 2022
In-Service Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7584804
7 April 2022
DAPI Audit · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7424995
3 February 2022
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7388503
2 November 2021
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7343424
6 October 2021
Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7328211
6 October 2021
Type not recorded
No type recorded · Station Hatteras Inlet · USCG East District (CGD-E) · Activity 7333897
6 October 2021
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7339872
3 May 2021
Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7186374
13 January 2021
Special
Type not classified · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7124391
9 July 2020
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7002537
23 June 2020
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6981189
28 May 2020
Administrative Inspection · Special
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6969260
25 February 2020
Internal Structural Exam · Examination of Repairs · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6915556
7 September 2019
Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6809291
21 May 2019
Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6689663
22 May 2018
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6419677
22 February 2018
Internal Structural Exam · Hull Examination · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6369220
2 May 2017
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6188404
18 April 2017
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6126400
18 July 2016
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5945917
3 May 2016
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5867282
2 March 2016
Hull Examination · Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5825307
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 30 April 2024
Resolved
Each vessel that operates on the high seas must have an EPIRB installed to automatically float free and activate. EPIRB hydrostatic release is expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 13 May 2024
Resolution: Installed new hydrostatic release.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 30 April 2024
Resolved
If the vessel life float does not have a painter attachment fitting a means for attaching the painter must be provided by a wire or line that meets requirements in 46CFR180.20-1(A)(3). Ensure the painter encircles the body of the life float and knot at weak link is secured.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 13 May 2024
Resolution: Painter line properly secured to lifefloat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 April 2024
Resolved
Each life buoy water light must have a line attached that is no less than 3 ft. in length and no more than 6 ft. in length and attached around the body of the life buoy. Line for water light is too short and wont secure around the body of the life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 13 May 2024
Resolution: Line of sufficient length was installed to life buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 April 2024
Resolved
A life jacket must be provided for all adults and
children on board and retro reflective material must be
affixed IAW 46CFR185.604(h). Retro was found wasted on
all lifejackets. Perform maintenance on life jackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 13 May 2024
Resolution: Retro on all lifejackets was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 April 2024
Resolved
Drip pans fitted with flame screen may be required under fuel strainers. Racor filter for the STBD MDE is not installed. IAW 46CFR182.20-40(B)(5)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 13 May 2024
Resolution: Flame screen reinstalled underneath Racor filter on STBD MDE.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 26 April 2023
Resolved
Port IBA is not rigged properly; the IBA painter line was not secured to the weak link. Ensure float free arrangement is utilized IAW 46CFR180.130.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 April 2023
Resolved 26 April 2023
Resolution: MIs received pictures of the IBA rigged properly with the painter secured to the weak link.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 April 2023
Resolved
Battery box in engine room is crack. Replace IAW 46CFR183.01-15.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2023
Resolved 26 April 2023
Resolution: MIs received pictures of the battery installed in a new box.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 April 2023
Resolved
First aid kit is expired. Refill or replace IAW 46CFR184.710. Kit must be approved under 160.041 Coast Guard Approval.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2023
Resolved 26 April 2023
Resolution: MIs received proof of purchase for a new first aid kit.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 November 2021
Resolved
STBD upper deck hand rail loose with undersized fasteners. Ensure rails are properly installed IAW 46CFR177.900
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 November 2021
Resolution: New fastener installed and pull tested.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 November 2021
Resolved
Galley light covers cracked and missing. Install light covers IAW 46CFR183.410.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 November 2021
Resolution: New covers installed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 November 2021
Resolved
Anchor line fraying in the eye at the shackle, renew IAW 46CFR184.300
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 November 2021
Resolution: Removed first 2 feet of line and re-attached.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 October 2021
Resolved
[name withheld] suffered potential damage to hull or propulsion system after grounding. Vessel to be hauled out for further inspection, prior to carrying passengers IAW 46CFR176.840.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2021
Resolution: Inspected and found hull in good condition.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 23 June 2020
Resolved
Lifefloats onboard must be marked with vessel name and attached to the vessel via weaklink. Repaint/Mark painted floats, reattach weaklink and ensure floats are tethered when stacked.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 9 July 2020
Resolution: Lifefloats have been propperly marked and stowed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 June 2020
Resolved
Lifebuoy must meet size requirements of 46 CFR subchapter T. Replace current ring with proper size and replace line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 9 July 2020
Resolution: 24" Ring Lifebuoy has been installed with appropriate lifeline and floating waterlight.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 23 June 2020
Resolved
Repair/Replace visual indicator for high water alarm, currently audib;e, but visual indicator for tank room is INOP.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 9 July 2020
Resolution: Bulb was replaced in visual indicator; op test sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 June 2020
Resolved
Install double hose clamp for raw water suppy on main diesel engine.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 9 July 2020
Resolution: Double hose clamps have been installed.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 7 September 2019
Resolved
Vessel received storm damage to the port fwd rubrail and main deck. Complete repairs.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 October 2019
Resolved 19 September 2019
Resolution: Repairs have been completed; op test sat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 May 2018
Resolved
Found a floating waterlight housing cracked. replace waterlight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2018
Resolved 6 June 2018
Resolution: Replaced water light.
Lifesaving › Lifefloat › Float-free Link
Issued 22 May 2018
Resolved
Found the tag missing on a lifefloat weak link. replace weak link.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2018
Resolved 6 June 2018
Resolution: Replaced weak link.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 22 May 2018
Resolved
Found the EPIRB hydrostatic release expired. Replace hydrostatic release.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2018
Resolved 6 June 2018
Resolution: Replaced hydrostatic release.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 18 April 2017
Resolved
Found original FCC Radio Safety Certificate missing. Provide original onboard vessel.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 22 June 2017
Resolution: Valid FCC Safety Radio Certificate on board expires 05/26/2021.
Navigation › Piloting/Steering › US Coast Pilot
Issued 18 April 2017
Resolved
Found Coast Pilot [name withheld], and Tidal Currents out of date. Procure recent pubs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 2 May 2017
Resolution: Current publications have been procured and placed on the vessel.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 18 April 2017
Resolved
Found #1 MDE battery switch housing broken. Replace battery switch.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 2 May 2017
Resolution: Battery switch has been replaced.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 18 April 2017
Resolved
Found SSDG selector switch box broken. Replace enclosure.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 26 June 2017
Resolution: All old wires have been disconnected and taped. Switch is no longer used.
Lifesaving › Lifefloat › Markings
Issued 18 April 2017
Resolved
Found life floats not labeled with vessel name. Label life float.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2017
Resolved 2 May 2017
Resolution: Lifefloats have been properly marked.
Communications › Radio Communications › VHF Radiotelephone
Issued 3 May 2016
Resolved
Vessel has 6 months to come in compliance with the Class A VHF-DSC requirements or 9 months if seeking an excemption through/from the FCC.
Action required: 705 - Other - as specified
Due 3 January 2017
Resolved 18 July 2016
Resolution: Installed VHF-DSC radio; MMSI #367340220.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 2 March 2016
Resolved
Ground vessel properly along grounding strip as needed for all broken wires now not attached to the grounding strip.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 3 May 2016
Resolution: Vessel appears to be properly grounded to grounding strip.
Engineering › Bilge Water Management System › Not Operational
Issued 2 March 2016
Resolved
Repair broken wire on the bilge switch in the tank room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 3 May 2016
Resolution: Broken wire on the bilge switch was renewed with a new bilge alarm switch.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 March 2016
Resolved
Cap all dead end wires on vessel as needed.
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 3 May 2016
Resolution: Dead end wires appear to be removed or capped.
Stability › Watertight Integrity › General
Issued 2 March 2016
Resolved
Replace gaskets as needed on flushdeck watertight hatches and improve operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 3 May 2016
Resolution: WTH's appear to be functioning and closing properly.