Records from 1993 to 2026. Most recent: inspection, 13 April 2026.
Inspection history · 75
13 April 2026
Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8314954
12 February 2026
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8309723
11 February 2025
Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8075077
30 April 2024
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7904009
31 January 2024
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7858378
27 June 2023
Administrative Inspection
Administrative · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 7724611
26 April 2023
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7675815
23 December 2022
In-Service Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7613271
27 October 2022
In-Service Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7584804
7 April 2022
DAPI Audit · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7424995
3 February 2022
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7388503
2 November 2021
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7343424
6 October 2021
Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7328211
6 October 2021
Type not recorded
No type recorded · Station Hatteras Inlet · USCG East District (CGD-E) · Activity 7333897
6 October 2021
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7339872
3 May 2021
Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7186374
13 January 2021
Special
Type not classified · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7124391
9 July 2020
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7002537
23 June 2020
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6981189
28 May 2020
Administrative Inspection · Special
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6969260
25 February 2020
Internal Structural Exam · Examination of Repairs · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6915556
7 September 2019
Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6809291
21 May 2019
Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6689663
22 May 2018
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6419677
22 February 2018
Internal Structural Exam · Hull Examination · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6369220
2 May 2017
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6188404
18 April 2017
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6126400
18 July 2016
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5945917
3 May 2016
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5867282
2 March 2016
Hull Examination · Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5825307
4 August 2015
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5212527
23 May 2014
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 4866151
14 June 2012
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4344627
28 May 2012
Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4329510
28 May 2012
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4329554
13 February 2012
Internal Structural Exam · Drydock Exam · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4243495
1 December 2011
Administrative Inspection
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4199205
27 September 2011
Administrative Inspection
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 4155533
16 March 2010
Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3696184
20 April 2009
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 3456933
8 April 2008
Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3177338
6 February 2008
Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3143094
3 April 2007
COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2901029
17 August 2006
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 2758096
13 April 2006
Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2619451
1 March 2006
Hull Examination · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2595189
11 April 2005
Annual Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2329084
19 April 2004
Annual Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2049334
4 March 2004
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2018725
22 September 2003
In-Service Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1944958
26 May 2003
Damage Survey · Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1814984
26 May 2003
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1867428
28 April 2003
Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1784465
14 April 2003
Annual Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1775361
10 April 2002
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1602843
6 March 2002
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1491435
12 June 2001
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1066665
23 April 2001
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1469032
3 May 2000
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 819372
6 April 2000
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1471223
5 April 2000
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1050115
8 March 2000
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1399311
10 May 1999
COI Inspection · Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1447951
6 April 1998
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1378332
7 January 1998
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1398820
14 April 1997
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1406096
15 April 1996
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1452144
12 January 1996
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1456321
2 May 1995
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 868054
6 March 1995
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1392178
20 September 1994
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 88964
9 March 1994
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1414285
3 November 1993
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1154646
29 April 1993
Initial Construction-Excluding Oversight · Hull Examination · Initial Certification
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1428230
19 April 1993
Initial Construction-Excluding Oversight
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 837229
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 30 April 2024
Resolved
Each vessel that operates on the high seas must have an EPIRB installed to automatically float free and activate. EPIRB hydrostatic release is expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 13 May 2024
Resolution: Installed new hydrostatic release.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 30 April 2024
Resolved
If the vessel life float does not have a painter attachment fitting a means for attaching the painter must be provided by a wire or line that meets requirements in 46CFR180.20-1(A)(3). Ensure the painter encircles the body of the life float and knot at weak link is secured.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 13 May 2024
Resolution: Painter line properly secured to lifefloat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 April 2024
Resolved
Each life buoy water light must have a line attached that is no less than 3 ft. in length and no more than 6 ft. in length and attached around the body of the life buoy. Line for water light is too short and wont secure around the body of the life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 13 May 2024
Resolution: Line of sufficient length was installed to life buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 April 2024
Resolved
A life jacket must be provided for all adults and
children on board and retro reflective material must be
affixed IAW 46CFR185.604(h). Retro was found wasted on
all lifejackets. Perform maintenance on life jackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 13 May 2024
Resolution: Retro on all lifejackets was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 April 2024
Resolved
Drip pans fitted with flame screen may be required under fuel strainers. Racor filter for the STBD MDE is not installed. IAW 46CFR182.20-40(B)(5)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 13 May 2024
Resolution: Flame screen reinstalled underneath Racor filter on STBD MDE.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 26 April 2023
Resolved
Port IBA is not rigged properly; the IBA painter line was not secured to the weak link. Ensure float free arrangement is utilized IAW 46CFR180.130.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 April 2023
Resolved 26 April 2023
Resolution: MIs received pictures of the IBA rigged properly with the painter secured to the weak link.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 April 2023
Resolved
Battery box in engine room is crack. Replace IAW 46CFR183.01-15.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2023
Resolved 26 April 2023
Resolution: MIs received pictures of the battery installed in a new box.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 April 2023
Resolved
First aid kit is expired. Refill or replace IAW 46CFR184.710. Kit must be approved under 160.041 Coast Guard Approval.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2023
Resolved 26 April 2023
Resolution: MIs received proof of purchase for a new first aid kit.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 November 2021
Resolved
STBD upper deck hand rail loose with undersized fasteners. Ensure rails are properly installed IAW 46CFR177.900
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 November 2021
Resolution: New fastener installed and pull tested.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 November 2021
Resolved
Galley light covers cracked and missing. Install light covers IAW 46CFR183.410.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 November 2021
Resolution: New covers installed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 November 2021
Resolved
Anchor line fraying in the eye at the shackle, renew IAW 46CFR184.300
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 November 2021
Resolution: Removed first 2 feet of line and re-attached.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 October 2021
Resolved
[name withheld] suffered potential damage to hull or propulsion system after grounding. Vessel to be hauled out for further inspection, prior to carrying passengers IAW 46CFR176.840.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2021
Resolution: Inspected and found hull in good condition.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 23 June 2020
Resolved
Lifefloats onboard must be marked with vessel name and attached to the vessel via weaklink. Repaint/Mark painted floats, reattach weaklink and ensure floats are tethered when stacked.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 9 July 2020
Resolution: Lifefloats have been propperly marked and stowed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 June 2020
Resolved
Lifebuoy must meet size requirements of 46 CFR subchapter T. Replace current ring with proper size and replace line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 9 July 2020
Resolution: 24" Ring Lifebuoy has been installed with appropriate lifeline and floating waterlight.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 23 June 2020
Resolved
Repair/Replace visual indicator for high water alarm, currently audib;e, but visual indicator for tank room is INOP.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 9 July 2020
Resolution: Bulb was replaced in visual indicator; op test sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 June 2020
Resolved
Install double hose clamp for raw water suppy on main diesel engine.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2020
Resolved 9 July 2020
Resolution: Double hose clamps have been installed.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 7 September 2019
Resolved
Vessel received storm damage to the port fwd rubrail and main deck. Complete repairs.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 October 2019
Resolved 19 September 2019
Resolution: Repairs have been completed; op test sat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 May 2018
Resolved
Found a floating waterlight housing cracked. replace waterlight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2018
Resolved 6 June 2018
Resolution: Replaced water light.
Lifesaving › Lifefloat › Float-free Link
Issued 22 May 2018
Resolved
Found the tag missing on a lifefloat weak link. replace weak link.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2018
Resolved 6 June 2018
Resolution: Replaced weak link.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 22 May 2018
Resolved
Found the EPIRB hydrostatic release expired. Replace hydrostatic release.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2018
Resolved 6 June 2018
Resolution: Replaced hydrostatic release.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 18 April 2017
Resolved
Found original FCC Radio Safety Certificate missing. Provide original onboard vessel.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 22 June 2017
Resolution: Valid FCC Safety Radio Certificate on board expires 05/26/2021.
Navigation › Piloting/Steering › US Coast Pilot
Issued 18 April 2017
Resolved
Found Coast Pilot [name withheld], and Tidal Currents out of date. Procure recent pubs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 2 May 2017
Resolution: Current publications have been procured and placed on the vessel.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 18 April 2017
Resolved
Found #1 MDE battery switch housing broken. Replace battery switch.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 2 May 2017
Resolution: Battery switch has been replaced.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 18 April 2017
Resolved
Found SSDG selector switch box broken. Replace enclosure.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 26 June 2017
Resolution: All old wires have been disconnected and taped. Switch is no longer used.
Lifesaving › Lifefloat › Markings
Issued 18 April 2017
Resolved
Found life floats not labeled with vessel name. Label life float.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2017
Resolved 2 May 2017
Resolution: Lifefloats have been properly marked.
Communications › Radio Communications › VHF Radiotelephone
Issued 3 May 2016
Resolved
Vessel has 6 months to come in compliance with the Class A VHF-DSC requirements or 9 months if seeking an excemption through/from the FCC.
Action required: 705 - Other - as specified
Due 3 January 2017
Resolved 18 July 2016
Resolution: Installed VHF-DSC radio; MMSI #367340220.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 2 March 2016
Resolved
Ground vessel properly along grounding strip as needed for all broken wires now not attached to the grounding strip.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 3 May 2016
Resolution: Vessel appears to be properly grounded to grounding strip.
Engineering › Bilge Water Management System › Not Operational
Issued 2 March 2016
Resolved
Repair broken wire on the bilge switch in the tank room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 3 May 2016
Resolution: Broken wire on the bilge switch was renewed with a new bilge alarm switch.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 March 2016
Resolved
Cap all dead end wires on vessel as needed.
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 3 May 2016
Resolution: Dead end wires appear to be removed or capped.
Stability › Watertight Integrity › General
Issued 2 March 2016
Resolved
Replace gaskets as needed on flushdeck watertight hatches and improve operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 April 2016
Resolved 3 May 2016
Resolution: WTH's appear to be functioning and closing properly.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 May 2012
Resolved
Replace and ensure proper operation of starboard main engine wiring harness and engine gauge panel. Both were damaged in electrical fire on 28MAY12.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 May 2012
Resolution: Wiring harness and gauge panel replaced and operating properly.
Lifesaving › Lifefloat › Serviceable
Issued 20 April 2009
Resolved
Make repairs or replace the two 12 person life floats.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 April 2009
Resolution: Master repaired the life float with manufacturers repair compund.
Lifesaving › Lifebuoys › Serviceable
Issued 20 April 2009
Resolved
Renew retro-reflective tape on ring buoy and four adult PFDs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2009
Resolution: Owner renewed retro on the ring buoy and replaced the 4 PFD''s with new ones.
Construction/Loadline › Hull › Bracket
Issued 6 February 2008
Resolved
Forward peak on Stbd side deck longs showing water damage in overhead. Dry or remove rotted wood and sister, reattach to hull
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 March 2008
Resolved 8 April 2008
Resolution: Completed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 3 April 2007
Resolved
Renew flex hose IWO fixed fire suppression system.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 April 2007
Resolved 8 May 2007
Resolution: Replaced hose.
Lifesaving › Lifefloat › Float-free Link
Issued 3 April 2007
Resolved
Install 21 or more size float free-link IWO port lifefloat.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 April 2007
Resolved 8 May 2007
Resolution: Installed proper float free-link.
Lifesaving › Rescue Boat › Boarding Ladder
Issued 3 April 2007
Resolved
Provide suitable rescue platform IAW Sector NC's CID policy ltr, or provide approved life sling.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 8 April 2008
Resolution: Rescue platform provided.
Stability › Watertight Integrity › General
Issued 3 April 2007
Resolved
Renew rubber gasket IWO aft steering watertight hatch.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 8 April 2008
Resolution: Provided
Lifesaving › Lifefloat › Platform
Issued 7 April 2006
Resolved
Install stainless steel ring or other suitable platform IWO 1 - 12 man life-float IAW 46 CFR 160.027-3.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2006
Resolved 12 April 2007
Resolution: Installed.
Communications › Alarms/Indicators › High Water Alarm
Issued 11 April 2005
Resolved
PROVIDE VISUAL INDICATOR FOR THE BILGE HIGH LEVEL ALARM FOR EACH COMPARTMENT. CURRENTLY VESSEL ONLY HAS AUDIBLE ALARM INSTALLED.
Action required: 705 - Other - as specified
Due 11 May 2005
Resolved 18 May 2005
Resolution: Visual indicators installed.
Communications › Radio Communications › EPIRB
Issued 11 April 2005
Resolved
PROVIDE VALID, OPERATIONAL EPRIB WITH PROPER REGISTRATION, HYDROSTATIC RELEASE AND BATTERY. RESTRICTED TO OPERATING WITHIN ONE MILE FROM SHORE UNTIL CORRECTED.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2005
Resolved 12 April 2005
Resolution: VESSEL OWNER PROVIDE VALID EPRIB WITH VALID HYDRO RELEASE, EXPIRATION DATE OF 4/2007 AND BATTERY EXPIRATION DATE OF 6/2010.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 26 May 2003
Resolved
Ensure proper operation of both main engines.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 June 2003
Resolved 3 June 2003
Electrical › Electrical Distribution System (service)
Issued 26 May 2003
Resolved
Repair all damged wiring. LEGACY COMPONENT DESC: Wiring
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 June 2003
Resolved 3 June 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 26 May 2003
Resolved
Service fixed fire extinguishing system for the engine room. LEGACY COMPONENT DESC: Quantity of CO2
Action required: 705 - Other - as specified
Due 27 June 2003
Resolved 3 June 2003
Fire Fighting › Ventilation Systems
Issued 26 May 2003
Resolved
Install/Provide closings for all air ducts to spaces protected by fixed fire extinguishing system. LEGACY COMPONENT DESC: Duct Hatches
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 June 2003
Resolved 3 June 2003
Documentation › Certificates/Documents
Issued 14 April 2003
Resolved
Post COI LEGACY COMPONENT DESC: Certificate of Inspection
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 28 April 2003
Personnel › Certificates/Documents/Licenses
Issued 14 April 2003
Resolved
Provide First Aid and CPR Cards. LEGACY COMPONENT DESC: Certificate, CPR Course Completion
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 14 April 2003
Resolution: Corrected prior to completing the inspection.
Documentation › Logs/Records
Issued 14 April 2003
Resolved
Provide Waste Management Plan. LEGACY COMPONENT DESC: Garbage Recordkeeping
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 14 April 2003
Resolution: Corrected prior to completing the inspection.
Engineering › Bilge Water Management System
Issued 14 April 2003
Resolved
Label bilge manifold. LEGACY COMPONENT DESC: Manifold
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 28 April 2003
Engineering › Shafting/Propeller Arrangements
Issued 14 April 2003
Resolved
Adjust/Repair leakage around shaft logs. LEGACY COMPONENT DESC: Stern Tube Lubrication/Sealing
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 14 April 2003
Resolution: Corrected prior to completing the inspection.
Documentation › Markings/Placards
Issued 14 April 2003
Resolved
Label ladders to upper deck for maximum number of passengers '30'. LEGACY COMPONENT DESC: Capacity Marking
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2003
Resolved 28 April 2003
Lifesaving › Buoyant Apparatus
Issued 14 April 2003
Resolved
Provide new 12 person lifefloat.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2003
Resolved 28 April 2003
Lifesaving › Buoyant Apparatus
Issued 14 April 2003
Resolved
Provide 2 new weak links for lifefloats.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2003
Resolved 28 April 2003
Navigation › Piloting/Steering
Issued 14 April 2003
Resolved
Provide U.S. Coast Pilot LEGACY COMPONENT DESC: US Coast Pilot
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 28 April 2003
Navigation › Piloting/Steering
Issued 14 April 2003
Resolved
Provide CG Light List LEGACY COMPONENT DESC: Coast Guard Light List
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 28 April 2003
Navigation › Piloting/Steering
Issued 14 April 2003
Resolved
Provide Tide Tables. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 14 April 2003
Resolution: Corrected prior to completing the inspection.
Navigation › Piloting/Steering
Issued 14 April 2003
Resolved
Provide Tidal Current Tables. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 28 April 2003
Pollution Prevention/Response › Prevention Equipment
Issued 14 April 2003
Resolved
Install 3/4 full indicator for MSD tank. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 28 April 2003
Lifesaving › Lifejacket/PFD (General)
Issued 14 April 2003
Resolved
Mark life jacket stowage areas. LEGACY COMPONENT DESC: Storage
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2003
Resolved 28 April 2003
Documentation
Issued 23 April 2001
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 23 April 2001
Resolved 23 April 2001
Documentation
Issued 23 April 2001
Resolved
PROVIDE PROOF OF VALID FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 23 April 2001
Resolved 23 April 2001
Navigation
Issued 6 April 2000
Resolved
POST EMERGENCY BROADCAST PLACARD NEAR VHF RADIO.
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Lifesaving
Issued 6 April 2000
Resolved
PROVIDE PROOF OF NOAA REGISTRATION FOR 406 EPIRB.
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Documentation
Issued 6 April 2000
Resolved
PROVIDE CURRENT STICKER FOR CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Construction/Loadline
Issued 8 March 2000
Resolved
REPLACE BONDING STRAP ON THROUGH HULL IN TANK ROOM.
Condition: Unknown
Due 8 March 2000
Resolved 8 March 2000
Construction/Loadline
Issued 8 March 2000
Resolved
DOUBLE CLAMP AND RENEW HOSES AS NEEDED ON BAITWELL THROUGH HULL FITTINGS.
Condition: Unknown
Due 8 March 2000
Resolved 8 March 2000
Construction/Loadline
Issued 8 March 2000
Resolved
MAKE COLLISION BULKHEAD WATERTIGHT NEAR CENTERLINE TOP.
Condition: Unknown
Due 8 March 2000
Resolved 8 March 2000
Construction/Loadline
Issued 8 March 2000
Resolved
RENEW BILGE PUMP (ELECTRIC) SUCTION LINE IN ENGINE ROOM.
Condition: Unknown
Due 8 March 2000
Resolved 8 March 2000
Construction/Loadline
Issued 8 March 2000
Resolved
REPLACE GASKETS ON FOREPEAK AND AFT LAZARETTE DECK HATCHES.
Condition: Unknown
Due 8 March 2000
Resolved 8 March 2000
Construction/Loadline
Issued 8 March 2000
Resolved
ATTACH FOREPEAK AND AFT LAZARETTE HATCHES WITH CHAIN OR LINE TO MAIN DECK.
Condition: Unknown
Due 8 March 2000
Resolved 8 March 2000
Documentation
Issued 10 May 1999
Resolved
SUPPLY RECIEPT FOR PAID USER FEES.
Condition: Unknown
Due 9 June 1999
Resolved 19 May 1999
Documentation
Issued 10 May 1999
Resolved
SUPPLY CURRENT COPY OF RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Lifesaving
Issued 10 May 1999
Resolved
REGISTER EPIRB WITH NOAA NESDIS.
Condition: Unknown
Due 10 May 1999
Resolved 17 May 1999
Lifesaving
Issued 10 May 1999
Resolved
REATTACH SEAPAINTER TO LIFE FLOATS THROUGH THE FACTORY PROVIDED TOWING EYE.
Condition: Unknown
Due 10 May 1999
Resolved 17 May 1999
Lifesaving
Issued 10 May 1999
Resolved
RETIE LIFE FLOAT PENDANTS IAW 46 CFR.
Condition: Unknown
Due 10 May 1999
Resolved 17 May 1999
Lifesaving
Issued 10 May 1999
Resolved
PROVIDE LIGHTS AND ATTACH TO LIFE JACKETS AS REQUIRED BY 46 CFR 180.75.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Documentation
Issued 7 January 1998
Resolved
PROPERLY MARK OFFICIAL NUMBERS AS PER 46 CFR 67.121
Condition: Unknown
Due 7 January 1998
Resolved 7 January 1998
Construction/Loadline
Issued 29 April 1993
Resolved
INSTALL SHUT-OFF VALVES AT THRU-HULL FITTINGS FOR DEEP WELL.
Condition: Unknown
Due 29 April 1993
Resolved 29 April 1993
Engineering
Issued 29 April 1993
Resolved
PROVIDE GUARDS OVER ROTATING PARTS ON BOTH MAIN DIESEL ENGINES.
Condition: Unknown
Due 29 April 1993
Resolved 29 April 1993