Records from 2016 to 2024. Most recent: inspection, 28 March 2024.
Inspection history · 25
28 March 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7886320
6 February 2024
PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7860509
4 February 2024
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7860019
5 March 2022
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7405529
14 December 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7368119
3 December 2021
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7362070
8 June 2021
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7219355
31 March 2021
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7166481
23 December 2020
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7130610
1 October 2020
Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7069343
11 September 2020
PSC B
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7054618
17 March 2020
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6928325
6 January 2020
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6881132
2 December 2019
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6865541
28 October 2019
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6843776
30 September 2019
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6824609
1 October 2018
Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6564661
11 September 2018
ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6537947
8 August 2018
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6504556
11 April 2018
ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6389596
12 September 2017
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6264363
19 June 2017
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6178129
29 March 2017
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6113473
24 March 2017
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6114724
31 August 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5988619
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 February 2024
Resolved
The ignitability of combustible materials shall be restricted. PSCO observed oil soaked lagging around M/E drain line.
74SOLAS(09) II-2/ 4.1.3
10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 February 2024
Resolved 6 February 2024
Resolution: Lagging was replaced during exam.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 February 2024
Resolved
After any survey of the ship under regulations 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the administration. PSCO observed modifications to the HFO purifier and a temporary repair on the sludge supply line to the incinerator.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 March 2024
Resolution: 28MAR24: Received class and flag reports stating outstanding deficiency has been rectified. The report states the modifications were removed and system was restored to original design.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 February 2024
Resolved
The pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed an air leak coming from the discharge value on #2 M/E control air reciever.
74SOLAS(04)II-1/26.1
40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 March 2024
Resolution: 28MAR24: Received clasa nd flag reports stating outstanding deficiency was rectified. The reports state that the packing gland was tightened and no further leaking has been noted.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 6 February 2024
Resolved
Escape routes shall be maintained in as safe condition. PSCO observed the door leading to the escape trunk on second level of Engine Room did not self close.
74SOLAS(09)II-2/13.1.2
10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 6 February 2024
Resolution: vessel crew fixed door
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 February 2024
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following requirements should be met: 1. Means shall be provided to control leaks of flammable liquids. PSCO observed active fuel leak on main engine fuel pump. Make repairs to the satisfaction of class and US Coast Guard prior to movement.
74 SOLAS (14) II-2/4.1.1
Action required: 60 - Rectify deficiencies prior to movement
Due 4 February 2024
Resolved 5 February 2024
Resolution: Set satisfactory class report attesting to repairs.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 4 February 2024
Resolved
Alleyways, stairways, and exits giving access to the muster and embarkation stations shall be lighted. PSCO observed twenty-one lights around the superstructure and deck non-operable, including eight emergency lights. Replace or repair non-operable lights.
74 SOLAS (20) III/11.5
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 February 2024
Resolved 4 February 2024
Resolution: 10c rectified on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 March 2022
Resolved
NOT LESS THASN HALF OF THE TOTAL NUMBER OF OF LIFEBUOYS SHALL BE PROVIDED WITH SELF-IGNIGHTING LIGHTS. [name withheld] 02 SELF-IGNITING LIGHTS WERE INOPERABLE. 74 SOLAS(04) III/7.1.3 10 C
Action required: 10 - Deficiency Rectified
Resolved 5 March 2022
Resolution: VESSEL REPLACED INOPERABLE LIGHTS ON LIFEBUOYS.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 3 December 2021
Resolved
Food rations shall be kept in airtight packaging. PSCO observed 08 food rations in lifeboat that were not airtight. 74 SOLAS(20) III/13.1.4, LSA 4.4.8.12
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 December 2021
Resolved 5 December 2021
Resolution: Vessel submitted survey statement from class displaying that the 08 food rations had been replaced with new ones.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 June 2021
Resolved
THE MACHINERY, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD. PSCO OBSERVED MAIN ENGINE LUBE OIL LEAKING FROM THE LUBE OIL PLATE HEAT EXCHANGER. 74 SOLAS (04) II-1/26.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2021
Resolution: Repaired / Rectified: Main engine lube oil cooler heat exchanger plates bolts were re-tightened per assembling measurement instruction. Thereafter, verified no leakage found along the heat exchanger lube oil plates.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 June 2021
Resolved
THE MACHINERY, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD. PSCO FOUND UNCONTROLLABLE JACKET WATER LEAK ON #3 GENERATOR. 74 SOLAS (04) II-1/26.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2021
Resolution: Repaired / Rectified: Cylinder head cover no.6 of main generator engine no.3 opened-up, overhauled and replaced with reconditioned cylinder head cover carried out by ship s crew.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 June 2021
Resolved
THE MASTER, OWNER, OPERATOR, AGENT OR PERSON IN CHARGE OF A VEWSSEL EQUIPPED WITH BALLAST TANKS THAT OPERATES IN THE WATERS OF THE UNITED STATES MUST EMPLOY ONE OF THE FOLLOWING BALLAST WATER METHODS LISTED IN 33 CFR 151.2025 PSCO OBSERVED VESSEL OPERATING WITH NO BALLAST WATER TREATMENT SYSTEM AND NO APPROVED EXTENSION LETTER. 33CFR151.2025
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 June 2021
Resolution: Upon the letter’s expiration, a vessel must
implement one of the approved ballast water management methods specified in 33 CFR 151.1510 or 151.2025. Vessel is not discharging ballast in US Waters.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 11 September 2020
Resolved
Doors fitted in boundary bulkheads of machinery spaces of catergory A shall be reasonably gas tight and self closing. 03 self closing doors in engineering spaces were not self closing properly as per the fire control plan. Two were found in the Steering Gear room and one was found in the Engine Control Room. SOLAS (14) Reg. 9.4.2.1, 17(c).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 September 2020
Resolved 11 September 2020
Resolution: The vessel made proper repairs to the self closing
doors. The lead PSCO witnessed proper operation.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 September 2020
Resolved
The purpose of this regulation is to detect a fire in the space of origin and to provide for alarm for safe escape and fire-fighting activity. Two of the three indicator column for general and fire alarm located in the lower level engine room(above the pure oil purifiers and aft engine room) were found to be inoperable. SOLAS(14) I Reg. 11(a), 40(a).
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 11 September 2020
Resolved 11 September 2020
Resolution: The vessel made proper repairs to the fire alarm indicators. The lead PSCO witnessed proper operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 September 2020
Resolved
The condition of the ship shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to ship or persons on board. The salt water cooling pump in the lower level engine room on the starboard side was found to be excessively leaking from a pin hole leak. SOLAS(14) I Reg. 11(a), 40(a)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 11 September 2020
Resolved 1 October 2020
Resolution: Received DNV-GL survey report attesting to repair of salt water cooling pump.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 11 September 2018
Resolved
0615 - Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Vessels rescue boat has damage to the portside hull, exposing the fiberglass. SOLAS 14 CH.III Reg. 20.2 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 September 2018
Resolved 1 October 2018
Resolution: Repaired / Rectified: Rescue boat port side fiberglass has been repaired by the crew member, in
accordance with manufacturer instructions using the repair kit provided on board and confirmed in order by the undersigned.