Records from 1992 to 2023. Most recent: inspection, 27 September 2023.
Documentation record
Registered dimensions (L × B × D)71.6 ft × 26.0 ft × 8.0 ft
Registered tonnagegross 143 / net 97
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · GREENVILLE, MS, UNITED STATES · built 1970
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCHICAGO, IL
Trade endorsementsCoastwise, Bowaters
DocumentationValid · issued 13 May 2026 · expires 30 June 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Net Ton
143 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 34
27 September 2023
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7799250
26 July 2023
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7757688
6 July 2023
Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7734493
2 June 2023
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7704315
5 July 2022
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7496628
25 May 2021
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7206692
12 April 2021
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7173898
16 December 2020
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7146854
11 November 2020
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7128347
5 May 2020
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6977274
5 February 2019
Initial Certification · Deficiency Check · In-Service Inspection · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6633699
8 March 2013
Administration
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4545503
10 June 2006
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2696532
12 April 2006
Uninspected Other
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2624592
13 February 2006
Type not recorded
No type recorded · USCG Great Lakes District (dpb) · USCG Great Lakes District (CGD-GL) · Activity 2584393
6 May 2005
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2410203
24 May 2004
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2099085
22 January 2004
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1990497
5 May 2003
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1786753
17 July 2002
Uninspected Towing Vessel
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1648773
29 January 2002
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1604005
28 January 2002
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1481825
22 May 2001
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 489340
5 May 2001
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 5250
11 November 2000
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 72398
11 August 2000
Uninspected Towing Vessel
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 822469
29 October 1997
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 409525
8 June 1997
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 29891
13 December 1996
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 50491
1 October 1996
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 24874
9 November 1994
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 660586
15 October 1994
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 10667
22 September 1994
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 17128
27 March 1992
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 104528
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 July 2022
Resolved
Upper deck ring life buoy needs new retro-reflective tape. Replace retro-reflective tape on ring life buoy.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 July 2022
Resolved 5 July 2022
Resolution: Retroreflective tape on ring life buoy was replaced in the presence of the Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 5 July 2022
Resolved
All bilges shall be kept free from accumulation of combustible and flammable liquids. Centerline bilge has excessive accumulation of fuel oil. Remove flammable and combustible liquids from centerline bilge prior to movement.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 5 July 2022
Resolved 5 July 2022
Resolution: Owner provided satisfactory evidence of removal of all flammable and combustible liquids from centerline bilge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 February 2019
Resolved
Repair or replace Bildge pump
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2019
Resolved 20 March 2019
Resolution: Installed new Bildge pump
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 5 February 2019
Resolved
Repair or replace E-lighting in Galley space
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2019
Resolved 20 March 2019
Resolution: New Battery installed
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 5 February 2019
Resolved
Installed closures on Ventilation
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2019
Resolved 20 March 2019
Resolution: Installed manual ventilation closure
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 February 2019
Resolved
Provide updated DAPI crew list and MIS report
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2019
Resolved 20 March 2019
Resolution: Review and excepted DAPI Audit and program
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 February 2019
Resolved
Provide final TVR for review
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 March 2019
Resolved 20 March 2019
Resolution: TVR reviewed