MAURY USCG vessel records
← All vessels

VELOS FORZA

VELOS FORZA is a 2010 tank ship. The Coast Guard has recorded 19 inspections since 2016, most recently in January 2025, along with 4 deficiencies and 2 operational controls.

Records from 2016 to 2025. Most recent: inspection, 15 January 2025.

Built
2010
Last inspected
15 January 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 January 2025
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9561370
1076801
Flag
MARSHALL ISLANDS
Maury page id
psix-1076801

Documentation record

Tonnage as PSIX records it58000 - Displacement, Metric Ton
48006 - Dead Weight, Metric Ton
28777 - Convention (Subpart B), Gross Ton
12680 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 5

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

LAVACA Industrial Vessel · MISLE 52958 · 28 April 2016 · activity 5934047MACY LYNN Towing Vessel · MISLE 127116 · 28 April 2016 · activity 5934047SHAWNEE Towing Vessel · MISLE 173813 · 28 April 2016 · activity 5934047MM 136 Tank Barge · MISLE 494052 · 28 April 2016 · activity 5934047NGL 3010 Tank Barge · MISLE 494148 · 28 April 2016 · activity 5934047

Inspection history · 19

15 January 2025 COE-Administrative
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8063954
15 January 2025 Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8064145
22 May 2024 COC-TVE Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7916416
15 March 2024 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7891788
20 May 2023 PSC B · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7692632
20 May 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7692771
21 February 2022 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7399705
16 February 2022 COC-TVE Renew · PSC B · Ballast Water Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7392067
10 January 2021 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7122219
23 November 2020 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7100491
17 July 2020 PSC B · COC-TVE Renew
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7005149
16 October 2018 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6562582
27 August 2018 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6524042
24 January 2017 COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6075897
22 January 2017 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6074855
8 December 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6051417
10 November 2016 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6038738
28 April 2016 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5934047
25 April 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5862244

Deficiency record · 4

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 May 2024 Resolved
Maintenance, testing and inspections shall be carried out based on the guidelines developed by the organization and in a manner having due regard to ensuring the reliabiliy of fire-fighting systems and appliances. A record of the age of the foam concentrates and of subsequent controls should be kept on board. MSC/Circ. 582 PSCO observed the foam test report on board reflecting 03MAR2023 as the last report. Vessel is past its annual due date for foam analysis and has no record of a new report. PSCO could not determine the reliability of the high and low expansion foam.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 May 2024
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 22 May 2024 Resolved
Oil fuel pipes, which, if damaged, would allow oil to escape from a storage, settling, or daily service tank having a capacity of 500 L and above situated above the double bottom, shall be fitted with a cock or valve directly on the tank capable of bein closed from a safe position outside the space concerned in the event of a fire occurring in the space in which such tanks are situated. PSCO observed inoperable remotely operated quick closing valve on generator #3. Valve was found in the open position prior to testing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 May 2024
Resolution: Corrected on the spot.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 22 May 2024 Resolved
A secondary means of allowing full flow relief of vapour shall be provided. Alternatively, pressure sensors may be fitted in each tank protected by the arrangement in paragraph 6.1.2. Such monitoring equipment shall also provide an alarm facility which is activated by detection of over-pressure or under-pressure within the tank. Starboard Slop Tank Radar is inoperable. Part Requisition submitted 19JUL2023. Replacement status unavailable.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 September 2024
Resolution: Zenner barrier and MIF-SB3 card were replaced with new spares, slop STBD tank radar monitoring system. ABS conducted remote survey clearing the deficiency.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 22 May 2024 Resolved
Each incinerator on a ship constructed on or after 01 JAN 2000.. each incinerator subject to this paragraph shall be approved by the Administration taking into account the standard specification for shipboard incinerators developed by the organization. PSCO observed substantial refractory degredation inside teh incinerator, presenting a hazard to the ship and crew.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 May 2024
Resolution: ABS surveyor verified repairs and function of incinerator.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.