Records from 2010 to 2025. Most recent: inspection, 15 January 2025.
Inspection history · 30
15 January 2025
COE-Administrative
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8063954
15 January 2025
Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8064145
22 May 2024
COC-TVE Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7916416
15 March 2024
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7891788
20 May 2023
PSC B · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7692632
20 May 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7692771
21 February 2022
Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7399705
16 February 2022
COC-TVE Renew · PSC B · Ballast Water Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7392067
10 January 2021
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7122219
23 November 2020
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7100491
17 July 2020
PSC B · COC-TVE Renew
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7005149
16 October 2018
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6562582
27 August 2018
ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6524042
24 January 2017
COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6075897
22 January 2017
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6074855
8 December 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6051417
10 November 2016
COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6038738
28 April 2016
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5934047
25 April 2016
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5862244
1 December 2015
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5772783
15 October 2015
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5743533
13 October 2015
ISPS III Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5741237
15 October 2014
COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5004716
11 October 2014
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5003344
16 June 2012
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4345557
24 December 2011
COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4213583
18 December 2011
COE-Dockside
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4214869
18 July 2011
ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4080035
20 December 2010
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3932034
12 November 2010
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3889772
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 May 2024
Resolved
Maintenance, testing and inspections shall be carried out based on the guidelines developed by the organization and in a manner having due regard to ensuring the reliabiliy of fire-fighting systems and appliances.
A record of the age of the foam concentrates and of subsequent controls should be kept on board. MSC/Circ. 582
PSCO observed the foam test report on board reflecting 03MAR2023 as the last report. Vessel is past its annual due date for foam analysis and has no record of a new report. PSCO could not determine the reliability of the high and low expansion foam.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 May 2024
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 22 May 2024
Resolved
Oil fuel pipes, which, if damaged, would allow oil to escape from a storage, settling, or daily service tank having a capacity of 500 L and above situated above the double bottom, shall be fitted with a cock or valve directly on the tank capable of bein closed from a safe position outside the space concerned in the event of a fire occurring in the space in which such tanks are situated.
PSCO observed inoperable remotely operated quick closing valve on generator #3. Valve was found in the open position prior to testing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 May 2024
Resolution: Corrected on the spot.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 22 May 2024
Resolved
A secondary means of allowing full flow relief of vapour shall be provided. Alternatively, pressure sensors may be fitted in each tank protected by the arrangement in paragraph 6.1.2. Such monitoring equipment shall also provide an alarm facility which is activated by detection of over-pressure or under-pressure within the tank.
Starboard Slop Tank Radar is inoperable. Part Requisition submitted 19JUL2023. Replacement status unavailable.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 September 2024
Resolution: Zenner barrier and MIF-SB3 card were replaced with new spares, slop STBD tank radar monitoring system. ABS conducted remote survey clearing the deficiency.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 22 May 2024
Resolved
Each incinerator on a ship constructed on or after 01 JAN 2000.. each incinerator subject to this paragraph shall be approved by the Administration taking into account the standard specification for shipboard incinerators developed by the organization.
PSCO observed substantial refractory degredation inside teh incinerator, presenting a hazard to the ship and crew.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 May 2024
Resolution: ABS surveyor verified repairs and function of incinerator.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 13 October 2015
Resolved
0750- Means shall be provided to control the leaks of flammable liquids. Flammable cargo is leaking at approximately 1 drop every 5 seconds from the # 3 cargo pump. The pump is currently out of service and zero LEL was detected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 October 2015
Resolved 1 December 2015
Resolution: Receieved Class Report attesting to the repairs of the cargo pump.
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 16 June 2012
Resolved
1830 - Cargo Transfer - The tank overfill alarm must have audible and visual indications where cargo transfer is controlled and in the cargo deck area. Overfill alarm for cargo tank No. 5 port side is not operational. 46CFR39.20-7(d)(2) Due to the satisfaction of USCG
Condition: Design Flaw
Due 16 July 2012
Resolved 24 August 2012
Resolution: Recieved class report attesting to the correction of the No. 5 port side overfill alarm. Report added to documents.