REGULATOR is a 1971 towing vessel. The Coast Guard has recorded 24 inspections since 1997, most recently in June 2025, along with 15 deficiencies, 1 operational control and 1 casualty investigation in 2023.

Records from 1997 to 2025. Most recent: inspection, 5 June 2025.

Built
1971
Last inspected
5 June 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 5 June 2025
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 15 calendar years (1997–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDL9989
107900
Flag
UNITED STATES
Maury page id
psix-107900

Documentation record

Registered dimensions (L × B × D)56.6 ft × 22.0 ft × 8.0 ft
Registered tonnagegross 96 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRAYCO SHIPBUILDERS & REPAIRS, INC · HOUMA, LA, UNITED STATES · built 1971
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCOOS BAY, OR
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 11 September 2025 · expires 31 October 2026
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it180 - Dead Weight, Ton
65 - Regulatory (Subpart C or D), Net Ton
96 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

LEANNE JOAN Freight Barge · MISLE 939417 · 19 April 2023 · activity 7695936

Inspection history · 24

5 June 2025 Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8168083
15 May 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8136576
18 June 2024 Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7934787
16 April 2024 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7906182
30 November 2023 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 7831256
28 November 2023 Deficiency Check · Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 7830492
31 October 2023 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7818141
19 April 2023 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7695936
22 September 2022 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7564710
2 September 2021 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7309126
6 November 2020 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7119357
24 May 2020 Initial Certification · Administrative Inspection · Re-Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6959471
8 January 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6607565
15 October 2015 Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5743604
18 August 2014 Hull Examination · Initial Certification
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4956111
2 August 2011 Industry Initiated Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4161055
18 January 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3698156
7 July 2006 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2709380
2 May 2006 MTSA Verification
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2640495
11 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1963164
5 November 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 40302
3 March 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 754049
27 February 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 155048
27 February 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 201960

Deficiency record · 15

08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 26 June 2025 Resolved
Crew unavailable to perform E/R alarms test.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 July 2025
Resolution: Conducted satisfactory E/R alarm tests.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 20 May 2024 Resolved
No audible and visual alarms for low oil pressure and high cooling water temp at operating station for both Aux generators,
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 June 2024
Resolved 18 June 2024
Resolution: Vessel installed Low Oil pressure, and high temp alarms for both generators.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 31 October 2023 Resolved
A towing vessel subject to this subchapter and choosing the Coast Guard inspection option, or required to have the Coast Guard inspection option, must undergo an annual inspection within 3 months before or after the COI anniversary date. Owners and managing operators must contact the cognizant Officer in Charge, Marine Inspection (OCMI) to schedule an inspection at a time and place the OCMI approves. Vessel did not complete annual inspection within required timeframe. Complete Coast Guard Inspection. No commercial operations are authorized until rectified.
Action required: 705 - Other - as specified
Due 31 January 2024
Resolved 30 November 2023
Resolution: Vessel had annual inspection on 30NOV23.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 31 October 2023 Resolved
Regardless of the option chosen to obtain a COI, upon obtaining a COI each towing vessel must then undergo a drydock and internal structural examination at the following intervals: A vessel that is exposed to salt water more than 6 months in any 12-month period since the last examination or initial certification must undergo a drydock and internal structural examination at least twice every 5 years, with not more than 36 months between examinations. Vessel did not complete drydock within the required timeframe. Complete Coast Guard drydock examination. No commercial operations are authorized until rectified.
Action required: 705 - Other - as specified
Due 31 January 2024
Resolved 28 November 2023
Resolution: Vessel had dry dock examination on 28NOV23.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 22 September 2022 Resolved
Means must be provided for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such spaces. The engine room vent opening on 2nd deck exhaust stack did not have means to secure ventilation. E/R vent opening on 2nd deck exhaust stack did not have a means to secure opening/ventilation.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2022
Resolved 21 October 2022
Resolution: Vent covers we had custom made for the exhaust stacks
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 22 September 2022 Resolved
Each mattress must comply with either The Consumer Product Safety Commission Standard for Mattress Flammability and not contain polyurethane foam, or comply with IMO Resolution A.688(17). The vessel operator to prove that the mattress is compliant with either standard. Provide documentation that mattresses onboard meet requirements in CFR.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2022
Resolved 21 October 2022
Resolution: Tag indicates 100% polyurethane foam
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 22 September 2022 Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford protection against hazards to life, property, and the environment. Sewage tank in the engine room had an opening on top that was plugged with a paper towel. Properly secure sewage tank.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2022
Resolved 21 October 2022
Resolution: MSD tank properly capped
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 September 2022 Resolved
Electrical systems must be designed and maintained to provide for safe operation of the towing vessel and safety of persons onboard under normal and emergency conditions. Three dead end wires beneath engine room ladder wrapped in electrical tape. Properly secure/cap dead end wires.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2022
Resolved 21 October 2022
Resolution: Dead end wiring removed under engine room stairs
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 22 September 2022 Resolved
Alarms must be visible and audible at each operating station. There are no visual high bilge level alarms at any of the operating stations
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2022
Resolved 26 October 2022
Resolution: Visible/audibe alarm in WH for high bilge water
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 22 September 2022 Resolved
Each watertight door and watertight hatch must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT DOOR - KEEP CLOSED” or “WATERTIGHT HATCH - KEEP CLOSED”. Watertight doors were not marked with proper verbiage on either side.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2022
Resolved 21 October 2022
Resolution: Watertight doors marked keep closed
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 22 September 2022 Resolved
The following list of items must be recorded in the TVR, official logbook, or in accordance with the TSMS applicable to the vessel: Navigation assessment, in accordance with § 140.635. Navigation assessment does not meet requirements in CFR
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 October 2022
Resolved 21 October 2022
Resolution: Navigation assessment provided and states the CFR
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 July 2020 Resolved
33CFR141.340(g)(1): Each lifejacket must have a lifejacket light approved under approval series 161.012 or 161.112 securely attached to the front shoulder area of the lifejacket. Lights attached to the onboard lifejackets were found to be inoperable (possibly failed batteries). 46 CFR 141.340
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 August 2020
Resolved 6 August 2020
Resolution: Lifejacket lights maintenanced and made operable.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 7 July 2020 Resolved
46CFR141.350: Each towing vessel operating north of latitude 32 degrees north or sugh of latitude 32 degrees south must carry at least one appropriate-size immersion suit, approved under approval series 160.171, for each person onboard. Vessel ARAPAHO is permitted for 6 persons onboard; at the time of inspection no immersion suits were available/onboard for inspection. 46 CFR 141.350
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 August 2020
Resolved 6 August 2020
Resolution: Operator acquired immersion suits and made available for inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 July 2020 Resolved
46CFR141.360(a)(2): A towing vessel of at least 26 feet but less than 75 feet, in length must carry a minimum of tow lifebuoys located on opposite sides of the vessel where personnel are normally present. The starboard side lifebuoy was found to be deteriorated and in need of being replaced. 46 CFR 141.360
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 August 2020
Resolved 6 August 2020
Resolution: Starboard side lifebuoy was replaced.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 2 May 2006 Resolved
Provide fire extinguishing system to protect engineroom. 46CFR 27.303
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 7 July 2006
Resolution: Vsl installed B-V to protect engineroom

Casualty record · 1

19 April 2023Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 7695936
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.