Records from 2011 to 2026. Most recent: inspection, 3 August 2026.
Inspection history · 37
3 August 2026
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8453370
23 April 2026
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8354516
17 February 2026
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8311238
15 September 2025
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8231879
13 September 2025
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8233652
13 September 2025
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8233675
11 September 2025
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8231619
3 September 2025
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8225315
3 September 2025
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8226339
29 August 2025
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8220545
3 June 2025
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8172112
31 May 2025
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8144418
28 May 2025
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8146099
13 March 2025
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 8091714
7 March 2025
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8088647
3 March 2025
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8087477
15 December 2024
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 8047602
6 December 2024
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8044396
16 September 2024
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 8003867
13 September 2024
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8001805
12 September 2024
PSC B · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7997203
13 June 2024
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7933897
27 December 2023
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7842874
22 December 2023
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7841459
19 December 2023
PSC B · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7837372
10 April 2023
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7665570
7 October 2022
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7561912
8 February 2022
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7392477
8 February 2022
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7392874
3 February 2022
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7390274
22 November 2021
Ballast Water Examination · MARPOL Annex VI Survey · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7355414
21 November 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7358441
17 November 2021
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7352772
14 May 2014
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4850180
3 March 2014
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4829592
27 August 2011
ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4120647
22 July 2011
NPV Safety Exam · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4090973
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 3 September 2025
Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed leaking diesel fuel oil on main cylinders B, G, D, M, C.
74 SOLAS(24) II-2/4.1.1
Action required: 15 - Rectify deficiencies by next port
Due 7 September 2025
Resolved 7 September 2025
Resolution: Receieved Class Report (attached in documents) attesting to repairs of leaks. Def rectified.
10 - Safety of Navigation › N/A - No Subsystem › Speed and distance indicator
Issued 13 March 2025
No resolution recorded
ALL SHIPS OF 300GT AND UPWARD SHALL BE FITTED WITH A SPEED DISTANCE MEASURING DEVICE OR OTHER MEANS TO INDICATE SPEED AND DISTANCE THROUGH WATER. VESSEL REPORTED THAT THEIR SPEED LOG IS INOPERATIVE.
74SOLAS(20) V/19.2.3.4
Action required: 705 - Other - as specified
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 March 2025
Resolved
Ships shall be designed, constructed and maintained in compliance with the structural, mechanical, and electrical requirements of a classification society... PSCO observed a portabl fan blowing on the electric motor of the low temperature cooling water pump in the cooler space.
SOLAS 74(04) CH.II-1/3-1
Action required: 15 - Rectify deficiencies by next port
Due 21 March 2025
Resolved 10 March 2025
Resolution: Satisfactory class report received.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 7 March 2025
Resolved
All electrical apparatus shall be so constructed & so installed as to not casue injury when handled or touched in the normal manner. PSCO observed one overhead light in one of the walkways between the cargo holds that was missing its cover and had exposed wires, in addition another light on the starboard side had a grounding wire that was disconnected. Exposed wires were located in the walkway between bays 30 and 34.
SOLAS 74(04) CH. II-1/45.1.3
Action required: 15 - Rectify deficiencies by next port
Due 21 March 2025
Resolved 10 March 2025
Resolution: Satisfactory class report received.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 7 March 2025
Resolved
The machinery, boilers, & other pressure vessels, associated piping systems& fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed water leaking from the inboard side of the #1 auxiliary generator from an unknown source.
SOLAS 74 (04) CH.II-I/26.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 25 April 2025
Resolved 10 March 2025
Resolution: Satisfactory class report received.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 7 March 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations...PSCO observed multiple lights and emergency lights extinguished throughout the interior and exterior of the vessel.
SOLAS 74(20) CH. II/11(a)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 25 April 2025
Resolved 31 May 2025
Resolution: PSCO inspected interior and exterior lighting and verified operation. RO issued survey statement attesting inoperative and missing lights have been repaired/provided.
14 - Pollution Prevention › 141 - MARPOL Annex I › 15 PPM Alarm arrangements
Issued 12 September 2024
Resolved
OIL FILTERING EQUIPMENT REFERRED TO IN PARAGRAPH 2 OF THIS REGULATION SHALL COMPLY WITH PARAGRAPH SIX OF THIS REGULATION. IN ADDITION, IT SHALL BE PROVIDED WITH ALARM ARRANGEMENTS TO INDICATE WHEN THIS LEVEL CANNOT BE MAINTAINED. THE SYSTEM SHALL ALSO BE PROVIDED WITH ARRANGEMENTS TO ENSURE THAT ANY DISCHARGE OF OILY MIXTURES IS AUTOMATICALLY STOPPED WHEN THE OIL CONTENT OF THE EFFLUENT EXCEEDS 15 PPM. IN CONSIDERING THE DESIGN OF SUCH EQUIPMENT AND APPROVALS, THE ADMINISTRATION SHALL HAVE REGARD TO THE SPECIFICATION RECOMMENDED BY THE ORGANIZATION. PSCO OBSERVED FAILURE OF AUTOMATIC STOP WHEN EFFLUENT EXCEEDED 15PPM, AS WELL AS NO AUDIBLE OR VISUAL ALARM IN THE SPACE.
MARPOL 1/.14.7
16AC
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2024
Resolved 16 September 2024
Resolution: MSU Savannah recieved Master's Statement and Class Report attesting to the proper operation of the Oily Water Seperator.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 19 December 2023
Resolved
74SOLAS (2020 cons.) III/31.1.1.1
One or more totally enclosed lifeboats complying with the requirements of section 4.6 of the code...
LSA Code (2010) 4.6.1/LSA Code (2010) 4.4.7.3
Except in the vicinity of the rudder and propeller suitable handholds shall be provided or a buoyant lifeline shall be becketed around the outside of the lifeboat above the waterline and within reach of a person in the water. PSCO observed wasted handhold lines on the port side4 of the port lifeboat.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2023
Resolution: Recieved photos and Flag attestestation of repairs to port side lifeboat handholds.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 3 March 2014
Resolved
On March 03, 2014, M/V CMA CGM DON GIOVANNI transited through the Western Alaska Captain of the Port zone while enroute to a U.S. port without a valid Geographic Specific Appendix for Western Alaska in its non-tank vessel response plan.
Due 3 March 2014
Resolved 20 March 2014
Resolution: A letter of warning was issued to the operating company on March 20, 2014.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 22 July 2011
Resolved
Every Master on a seagoing ship of 3000 GT or more shall hold an appropriate certificate. Contracting governments shall undertake, for each its national ships, to maintain or adopt, measures for the purposes of ensuring that, all ships shall be sufficiently manned. Vessel does not currently have a licensed Master on board, and is therefore not in compliance with Safe Manning Certificate or STCW.
Action required: 705 - Other - as specified
Resolved 24 July 2011