Records from 1995 to 2026. Most recent: inspection, 7 July 2026.
Inspection history · 60
7 July 2026
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8431333
7 April 2025
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8103511
9 July 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7953241
17 April 2024
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7889850
5 April 2024
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7890323
26 July 2023
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7751515
16 August 2022
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7534974
14 April 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7431462
6 May 2021
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7190900
9 December 2020
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7109422
9 December 2020
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7110241
1 October 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7067682
10 April 2019
Deficiency Check · Initial Certification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6648415
19 April 2018
Deficiency Check · Industry Initiated Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6416894
24 August 2012
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4424290
1 July 2011
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 4066290
25 March 2011
MTSA Verification · Industry Initiated Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3984007
19 October 2010
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3873450
7 October 2010
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3868119
22 February 2010
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3684507
26 February 2009
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3478260
24 February 2009
Type not recorded
No type recorded · Station Emerald Isle · USCG East District (CGD-E) · Activity 3423130
24 February 2009
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3424591
24 February 2009
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3478110
30 December 2008
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3388743
11 December 2008
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3378308
19 May 2008
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3225896
8 February 2007
Type not recorded
No type recorded · Maritime Safety & Security Team New York (91106) · Activity 2869283
6 April 2006
MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2628244
6 February 2006
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2580279
29 September 2005
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2508972
14 June 2005
Type not recorded
No type recorded · Station Hobucken · USCG East District (CGD-E) · Activity 2391262
14 October 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2220688
27 March 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2033437
21 March 2004
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2029006
1 January 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1975532
30 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1972314
28 October 2003
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1937727
17 October 2003
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1994997
16 October 2003
Type not recorded
No type recorded · Station Crisfield · USCG East District (CGD-E) · Activity 1930117
3 December 2002
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1714952
22 November 2002
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1709769
22 November 2002
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1710366
29 July 2002
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1653436
26 July 2002
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1652429
17 June 2001
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 116002
25 May 2001
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 102142
14 March 2001
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 103670
15 March 1999
Uninspected Towing Vessel
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1123914
10 August 1998
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 19955
30 April 1998
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 15460
17 April 1998
Uninspected Towing Vessel
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1131479
20 September 1997
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 45512
16 September 1997
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 54375
9 June 1997
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 25896
9 June 1997
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 212432
20 July 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 135592
2 February 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 86517
29 May 1995
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 47806
28 May 1995
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 467
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 7 July 2026
Resolved
Each ship subject to the Bridge-to-Bridge Act must have on board a radio operator who holds a restricted radiotelephone operator permit or higher class license. Vessel master did not provide proof of current radiotelephone operator permit.
47 CFR 80.163
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 July 2026
Resolution: O/O provided proof of FCC operator license.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 7 July 2026
Resolved
The master must ensure that all lifesaving equipment is properly maintained and ready for use at all times. Vessel did not have regular liferaft onboard at the time of inspection.
46 CFR 141.230
Action required: 10 - Deficiency Rectified
Resolved 14 July 2026
Resolution: O/o provided proof of loaner 6-man life raft onboard.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 7 April 2025
Resolved
The owner of a vessel subject to inspection under section 3301 shall-
(1) ensure that such vessel is equipped with a vessel master key control system, manual or electronic, which provides controlled access to all copies of the vessel's master key of which access shall only be available to the individuals described in paragraph (2);
(2) establish a list of all crew, identified by position, allowed to access and use the master key and maintain such list upon the vessel, within owner records and included in the vessel safety management system;
(3) record in a log book information on all access and use of the vessel's master key, including-
(A) dates and times of access;
(B) the room or location accessed; and
(C) the name and rank of the crew member that used the master key; and(4) make the list under paragraph (2) and the log book under paragraph (3) available upon request to any agent of the Federal Bureau of Investigation, any member of the Coast Guard, and any law enforcement officer performing official duties in the course and scope of an investigation. Vsl has no Master Key,
identified crew, or logbook.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2025
Resolved 15 April 2025
Resolution: VSL implemented key control requirments.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 7 April 2025
Resolved
Each towing vessel operating in those regions must carry at least one appropriate-size immersion suit, approved under approval series 160.171, for each person on board.
Vessel is equipped with 05 of 06 required immersion suits that are not appropriate size for crew, VSL to replace 02 Jumbo sized with adult universal sized.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2025
Resolved 15 April 2025
Resolution: VSL has appropriate sized immersion suits.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 26 July 2023
Resolved
The master of a towing vessel must ensure that drills are conducted and instructions are given to ensure that all crew members are capable of performing duties expected of them during emergencies. MI observed that no man overboard drill or abandon ship drill had been conducted within the last year.
46 CFR 140.420(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 July 2023
Resolved 26 July 2023
Resolution: Conducted man overboard drill
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 26 July 2023
Resolved
A towing vessel must carry adequate and up-to-date charts, maps, and nautical publications for the intended voyage. On board paper charts were 3-9 years old and without updates. Electronic charting system had not been updated since May 2022.
46 CFR 140.705(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2023
Resolved 1 August 2023
Resolution: Nautical charts updated through 11Jul23
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 July 2023
Resolved
Electrical components that pose an electrical hazard must be in an enclosure. CGMI observed exposed wire coming from a junction box on the bridge.
46 CFR 143.400(g)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2023
Resolved 1 August 2023
Resolution: Exposed wires were removed from the junction box
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 July 2023
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.
CGMI observed missing blank covers on port side breaker panel #1 in the engine room.
46 CFR 143.400(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2023
Resolved 1 August 2023
Resolution: Blank covers were installed on the breaker panel
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 April 2022
Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. Repair wasted fwd hatch and replace gasket.
46 CFR 140.610(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2022
Resolved 16 August 2022
Resolution: Observed satisfactory repair by attending MI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 April 2022
Resolved
The owner or managing operator must implement procedures to identify and mitigate health and safety hazards. Crop and renew wastage hole IWO port side stairs bridge deck with at least 18" x 18" insert plate.
46 CFR 140.510(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2022
Resolved 16 August 2022
Resolution: Observed satisfactory repair by attending MI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 April 2022
Resolved
The owner or managing operator must implement procedures to identify and mitigate health and safety hazards. Crop and renew wastage hole IVO crew members accommodation space with at least 18" x 18" insert plate.
46 CFR 140.510(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2022
Resolved 16 August 2022
Resolution: Observed satisfactory repair by attending MI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 April 2022
Resolved
The owner or managing operator must implement procedures to identify and mitigate health and safety hazards. Crop and renew wasted hole IVO stairs leading to topside of bridge with at least 18" x 18" insert plate.
46 CFR 140.510(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2022
Resolved 16 August 2022
Resolution: Observed satisfactory repair by attending MI.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 May 2021
Resolved
Towing vessels must minimize fire hazards. The fuel transfer system located on the forward bulkhead of the engine room has three small leaks in the fixed piping. Repair leaks to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 11 May 2021
Resolution: Loose valves were tightened to the satisfaction of the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 6 May 2021
Resolved
Means must be provided for closing ventilation in case of a fire. Vessel must provide means to secure ventilation to the engine room from the mushroom vent on the top deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2021
Resolved 28 May 2021
Resolution: Vessel made ventalation covers for engine room vents.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 December 2020
Resolved
Vessel required inspection after barge in tow allided with aid to navigation. 46CFR137.300(b)
Action required: 10 - Deficiency Rectified
Due 9 December 2020
Resolved 9 December 2020
Resolution: Inspection complete