Records from 2011 to 2024. Most recent: inspection, 1 October 2024.
Documentation record
Registered dimensions (L × B × D)246.3 ft × 56.0 ft × 19.5 ft
Registered tonnagegross 2,435 / net 1,097
ITC dimensions (L × B × D)246.3 ft × 56.0 ft × 19.5 ft
ITC tonnagegross 2,435 / net 1,097
BuilderQUALITY SHIPYARDS LLC · HOUMA, LA, UNITED STATES · built 2011
Hull materialSteel
PropulsionDiesel Direct
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 21 April 2026 · expires 30 April 2027
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1097 - Convention (Subpart B), Net Ton
2435 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 22
1 October 2024
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8013315
5 January 2024
Deficiency Check · Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7846024
19 July 2023
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7751670
12 December 2022
Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7609607
22 April 2022
Equivalency
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7436137
24 February 2022
Equivalency · Construction Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7410312
10 January 2022
ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7378119
12 July 2021
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7254345
7 October 2020
Administrative Inspection · ACP COI Oversight · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7073107
15 June 2020
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6977205
16 December 2019
MTSA/ISPS Verification · ACP COI Oversight · Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6872840
5 November 2019
Permit to Proceed · Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6850201
6 August 2019
Type not recorded
No type recorded · Station Key West · USCG Southeast District (CGD-SE) · Activity 6775452
28 May 2019
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6696379
14 November 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6134735
5 January 2016
ACP Annual Oversight · Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5791686
27 June 2012
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4358125
21 June 2012
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4351334
28 May 2012
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4476771
31 January 2012
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4235070
11 January 2012
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4222765
16 August 2011
Initial Certification · ACP Handover Survey · MTSA/ISPS Verification · Initial Construction-Excluding Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4117029
14 - Pollution Prevention › 146 - MARPOL Annex VI › Quality of fuel oil
Issued 8 January 2024
Resolved
The bunker delivery note shall be accompanied by a representative sample of the fuel oil delivered taking into account guidelines developed by the organization. The sample is to be sealed and signed by the supplier's representative and the master or officer in charge of the bunker operation on completion of bunkering operations and retained under the ship's control until the fuel oil is substantially consumed, but in any case for a period of not less than 12 months from the time of delivery. Vessel is missing fuel sample to accompany bunker delivery notes in SEP2023. Allegedly accidentally discarded by crewmember.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 January 2024
Resolution: Received satisfactory report from ABS.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 10 January 2022
Resolved
In the event of alterations involving the safety of the vessel, the applicable plans shall be submitted for approval.
All portable accommodation modules onboard must be reviewed, certified, and installed IAW CG-ENG Policy Letter 01-16 "Portable Accommodation Module (PAM) Guidance". Unapproved PAM's must not be used until requirements have been met.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 February 2022
Resolved 24 January 2022
Resolution: Vessel removed all PAMs from the vessel and ABS oversaw the removal and approval of all system restoration.
Documentation › Certificates/Documents › International Air Pollution Prevention Certificate
Issued 5 January 2016
Resolved
IAPP in need of update to reflect ship service diesel generators.
Action required: 705 - Other - as specified
Due 6 January 2016
Resolved 25 January 2016
Resolution: Class corrected error on paperwork.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 5 January 2016
Resolved
OWS system to match design drawings.
Action required: 705 - Other - as specified
Due 6 January 2016
Resolved 25 January 2016
Resolution: Class verified correction.
Fire Fighting › Structural - B Class Divisions › Doors
Issued 5 January 2016
Resolved
Fire doors to accommodations to latch when closed.
Action required: 705 - Other - as specified
Due 6 January 2016
Resolved 25 January 2016
Resolution: Class verified correction.