Records from 2010 to 2026. Most recent: inspection, 10 March 2026.
Inspection history · 37
10 March 2026
PSC B · COC-TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8323833
20 March 2025
COC-TVE Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8094864
5 March 2024
PSC B · COC-TVE Annual
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7874226
17 March 2023
COC-TVE Renew · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7650163
11 March 2022
PSC B · COC-TVE Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7409335
9 February 2022
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7393443
27 March 2021
COC-TVE Renew · PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7161319
9 May 2020
In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6955123
9 May 2020
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6955295
22 March 2020
PSC B · COC-TVE Annual
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6930142
29 October 2019
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6844503
25 March 2019
ISPS III Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6646267
21 November 2018
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6584816
4 October 2018
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6554596
28 September 2018
In-Service Inspection · MARPOL Annex I Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6548537
21 August 2018
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6518650
3 April 2018
COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6382036
29 September 2017
COE-Dockside · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6278085
16 August 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6242763
25 June 2017
COE-Administrative
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6181349
30 March 2017
ISPS II Exam · COE-Dockside · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6106976
24 January 2017
COE-Dockside
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6070479
3 July 2016
ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5927419
15 April 2016
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5862275
25 March 2016
Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5833781
18 February 2016
COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5817258
14 January 2016
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5797580
7 August 2014
COE-Dockside
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4937618
24 March 2014
ISPS II Exam · COE-Administrative · Ballast Water Examination · COC-TVE Annual
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4821745
19 December 2011
COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4210736
24 August 2011
PI Safety Exam · COC-TVE Annual · COE-Dockside · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4119751
24 August 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4125552
23 August 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4126047
24 July 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4091471
19 July 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4086753
17 July 2011
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4084313
6 September 2010
ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3835010
Deck/Cargo › Vapor Control Systems › Inerting System
Issued 30 March 2017
Resolved
1899-The inert gas system referred to in paragraph 5.5.3.1 shall be designed. constructed, and tested in accordance with the fire safety systems code. Alarms on the inert gas generator used for topping up were unable to be tested due to inability of inert gas generator to start. SOLAS 14 II-2/4.5.5.3.2
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2017
Resolved 30 March 2017
Lifesaving › Lifeboat › Watertight Enclosure
Issued 30 March 2014
Resolved
01 0610 Cargo ships shall carry totally enclosed lifeboats complying with section 4.6 of the code. Access to the lifeboat is provided by hatches which can be closed to make lifeboat watertight. Water was found in the bilge of the lifeboat. The most likely cause apears to be improper seating of hatch on lifeboat. Solas 74' (2009 Cons Ed.) III/31.1.1 LSA Code 4.6.2.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2014
Resolved 23 April 2014
Resolution: Class report indicates ship staff replaced the rubber gasket on the main hatches. The rubber sealing arrangement on the forward and aft hatches was inspected and found to be in order. Leakage test was carried out on the hull and on the hatches.
Lifesaving › Lifeboat › Hull
Issued 30 March 2014
Resolved
02 0610 The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Starboard side lifeboat showed evidence of light damage and temporary repair on stern port side. Solas74' (2009 Cons Ed.) 1/11
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 April 2014
Resolved 23 April 2014
Resolution: Class report indicates repairs on the boat were carried out by the manufacturer approved service supplier and as per their internal repair procedures, using fiber glass mating and polyester resin. The repairs were surveyed and found to be in order.
Construction/Loadline › Hull › Side Shell
Issued 24 August 2011
Resolved
1299-Other(Load Lines)- Vessel reported a collision with a passing vessel while transiting in-bound on the LMR. PSCO observed on the port quarter a 20 cm inset from frame 40 to 45, approximately 3m below deck line. Provide class report attesting to the structural integrity of the hull and any associated damage relating to collision.-ICLL 66 am 2008
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2011
Resolved 31 August 2011
Resolution: Received, reviewed and accepted class report / proper documentation from DNV stating the deficiency was rectified. Detached elements were temporarily repaired. Area was grinded, drilled to arrest cracks and welded. See narrative for details.
Documentation › Logs/Records › Oil Record Book
Issued 24 August 2011
Resolved
1710-Oil record book- The Oil Record Book (ORB) shall be completed on each occasion whenever the following machinery space operation occurs: collection of oil residues. Soundings for the "M/E Stuffing L.O. Drain Tank" have not been recorded in the ORB, as required in block 3.1 of the IOPP supplement. C/E stated he is not aware of this tank or its location. Provide Clarification. MARPOL Annex I/17
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 24 August 2011
Resolved 31 August 2011
Resolution: Received, reviewed and accepted class report / proper documentation from DNV stating the deficiency was rectified. M/E Stuffing L.O. Drain Tank was not identified and subsequently erased form table 3.1 of the IOPP supplement to the IOPP Certificate.